EDX-7000/8000/8100

Energy Dispersive X-ray Fluorescence Spectrometer

Total Elemental Impurities No Prep, One Click

No Prep, Non-Destructive, Easy
 


  • 4 Easy Steps!
  • FDA 21 CFR Part 11 Compliance Features Needed in Pharmaceutical Industry
  • LabSolutions DB/CS Data Management - Higher Efficiency
  • Drug Impurities Analysis Using X-Ray Fluorescence

 

4 Easy Steps!

Features

FDA 21 CFR Part 11 Compliance Features Needed in Pharmaceutical Industry

 

  • Security Function
  • Validation Function
  • Operation and Audit Trail Log Output Functions
  • User Right’s Management
  • Operation and Audit Trail Log Output Functions

 

Security Function

ID and password user authentication and Screen Lock allow only authorized users access, recorded in an Operational history log.

Audit Trail Log Output Function

Audit Trail logs including instrument setting change history and user operation history can be outputted.

LabSolutions DB/CS Data Management - Higher Efficiency

All analytical data including data obtained from other analytical instruments is managed on a database on the server computer, allowing data to be loaded and managed on any computers on the network.

Drug Impurities Analysis Using X-Ray Fluorescence
No Prep, Non-Destructive, Easy

X-ray fluorescence enables non-destructive, preparation-free analyses for residual metallic catalysts, impurities and harmful metals in active pharmaceutical ingredients (APIs). This technique can be easily introduced in any drug production processes with lower costs than chemical analysis methods that require time and labor preparative techniques, gases and ventilation.

EDX-7000/8000 - Easier Analysis For Metals in Drugs

A six-point calibration curve was created by adding platinum (Pt) standard to cellulose powder in the range from 0 to 20 ppm. The results in the table below show a good standard deviation (RMS) and linearity coefficient were achieved using only 100 mg of sample and a 20 minute analysis time. The results indicate that the system can perform analysis with high accuracy even with limited sample.

Element Concentration range (ppm) RMS(ppm) Correlation coefficient
Pt 0-20 0.25 0.9993

EDX Spectrum of Sample with Pt and As Mixed in Cellulose Powder

EDX Spectrum of Sample with Pt and As Mixed in Cellulose Powder

30 ppm platinum (Pt) peak is clearly detected as well as a 5 ppm arsenic (As) peak.

For Research Use Only. Not for use in diagnostic procedures.