GC Driver for OpenLAB CDS EZChrom Edition Ver. 2

Shimadzu Nexis GC-2030 gas chromatographs can now be controlled from Agilent OpenLAB CDS (chromatography data system). The Nexis GC-2030, which provides the world's highest level of performance and user-friendly interface, can now be used in an OpenLAB CDS environment.

 

 

 

Seamlessly Controls Shimadzu GC Units

The instrument status window includes a control panel able to directly control Shimadzu GC units. The control panel allows the GC system to be turned ON/OFF or connected/disconnected with a single button operation. The control panel also includes other features to help ensure Shimadzu GC units can be controlled conveniently, such as an instrument monitor where the system operating status can be confirmed with a single glance and a system check function that assists with routine instrument inspection. Windows used to edit instrument methods are configured for each instrument, so that even first-time Shimadzu GC users can specify GC instrument parameters easily. Shimadzu GC and headspace sampler operations can be controlled seamlessly from OpenLAB, including report output and audit trail functionality.

Control Panel

Control Panel

Compatibility with Nexis GC-2030

The following are examples of the advanced Nexis GC-2030 functionality that can be
used from OpenLAB.

  • Detectors with the world's highest level of sensitivity
  • High separation capability and productivity using Advanced Flow Technology
  • Gas saver and sleep functions for reducing energy consumption during standby
  • Graphical touch panel that allows intuitive operation

 

Window for Editing GC Methods

Window for Editing GC Methods

Maximize Productivity with Optimum Sample Injection

In addition to standard liquid analysis using an AOC-20i autoinjector, the following types of analysis are also supported.

  • Simultaneous analysis of two lines using a dual injection system
  • Successive switching between liquid and headspace analysis by installing both
    AOC-20i and HS-20 units

This optimal sample injection system helps maximize analytical productivity.

Using Instrument Methods for Smart Switching Between HS-20 and AOC Units

Using Instrument Methods for Smart Switching
Between HS-20 and AOC Units

 

For Research Use Only. Not for use in diagnostic procedures.

This page may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country.

Top of This Page