IRPrestige-21
Fourier Transform Infrared Spectrophotometer


Sensitivity

IRPrestige-21

  • High Signal to Noise Ratio;40,000:1 or better(NOTE 1)
  • High Energy Ceramic Light Source
  • High Throughput Optics
  • High Sensitivity DLATGS Detector

Reliability

  • Advanced Dynamic Alignment
  • Sealed and Dessicated Interferometer
  • Self Diagnostics & Status Monitoring
  • JP/EP/ASTM Validation

Accessory

  • NIR/MIR/FIR
  • Automatic Accessory Recognition-QuickStart Accessories
  • 3 Detector Selections for Various Applications
  • Wide Varieties of Accessories and High Performance IR Microscope

Software

  • 32bit Windows based IRsolution
  • High Performance and Easy Operation
  • Audit-trail
  • FDA 21 CFR Part 11 Compliance(NOTE 2)

IRPrestige-21 and IRsolution opens a new world for FTIR users

High sensitivity and expanded functionality for leading edge Research & Development.
Easy software and Automatic Accessory Recognition for User Friendly operation.
ADA (Advanced Dynamic Alignment) for optical system reliability
Status Monitoring and Validation Program
Near IR/Middle IR/Far IR
Wide variety of Accessories for a large range of applications
Powerful software - IRsolution - to enhance performance of IRPrestige-21.
Considering the environment, the electric power consumption while measuring is 25% reduced(NOTE 3).

IRPrestige-21 and IRsolution opens a new world for FTIR users.
(NOTE 1) 4cm-1 resolution, 1 minute accumulation, around 2,100cm-1, peak to peak
(NOTE 2) IRsolution Agent software is needed to fully comply to FDA 21 CFR Part 11 regulation.
(NOTE 3) Comparison with the previous Shimadzu FTIR.

Specifications

Hardware
Interferometer Michelson interferometer (30 degree incident angle)

Advanced Dynamic alignment system

Sealed and desiccated interferometer with an automatic dryer
Optical system Single beam optics
Beam splitter Germanium-coated KBr plate for Middle IR (Standard)

Germanium-coated CsI plate for Middle/Far IR (Optional)

Silicon-coated CaF2 plate for Near IR (Optional)
Light source Air Cooled Ceramic for Middle/Far IR with 3 years guarantee (Standard)

Tungsten lamp for Near IR (Optional)
Detector DLATGS detector with Temperature Control for Middle/Far IR (Standard)

MCT(Hg-Cd-Te) detector with Liquid Nitrgen Cooling for Middle IR(Optional)

InGaAs detector for Near IR (Optional)
Wavenumber range 7,800 - 350 cm-1

12,500 - 240 cm-1 (Optional. See Figure for detail)
Resolution 0.5 cm-1, 1 cm-1, 2 cm-1, 4 cm-1, 8 cm-1, 16 cm-1 (Middle/Far IR)

2 cm-1, 4 cm-1, 8 cm-1, 16 cm-1 (Near IR)
S/N ratio 40,000: 1 and higher

(Peak-to-peak, 4 cm-1 resolution, around. 2100 cm-1, 1 minute scan)
Mirror speed 3-step selection of 2.8, 5, or 9 mm/sec

Scanning at 4 cm-1 takes from 2-3 sec
Data sampling He-Ne laser with 30 months guarantee
Gain control Automatic or manual from x1 - x128
Sample compartment Automatic Accessory Recognition

200 (W) x 230 (L) x 170 (H) mm

Center Focus
Dimensions 600 (W) x 680 (L) x 290 (H) mm
Weight 54Kg

Scan Range

Light Source Beam Splitter Detector Scan Range(cm-1) Necessary Parts
Tungsten CaF2 InGaAs 12,500-3,800 NIR Kit (206-72015-91)
Ceramic KBr DLATGS 7,800-350 Standard
MCT 5,000-720 MCT Kit (206-72017-91)
CsI DLATGS 5,000-240 FIR Kit (206-72016-91)
(Caution) The beam splitters must be kept inside of IRPrestige-21 or a desiccator.

Scan Wavenumber with options

The orange bar expresses the wavenumber range which can be measured with the standard elements. The red, yellow and brown bars express the wavenumber range which can be measured with the optional elements.
Picture


This page may contain references to products that are not available in your country.
Please contact us to check the availability of these products in your country.