Natural Gas Analysis
Recently, natural gas has been recognized as a clean resournce for energy, in addition to being a raw material for chemical products. Recently a cutting-edge drilling technology has increased the use of shale gas. As the production area diversifies, the need for gas composition analysis has increased. Shimadzu addresses analytical requests with a wide system GC lineup. For analysis of liquified gas, such as LPG, a dedicated injector with a vaporizer is available. Both manual injection and online injection are available. The operation software can automatically calculate needed values, such as indexes, calorific values, etc.
The ultrafast natural gas analyzer UFRGA is here.
Natural Gas Analysis System Lineup
Model Name | Nexis GC-2030 BIDUFNGA | Nexis GC-2030FNGA-II1 | Nexis GC-2030FNGA-II2 | Nexis GC-2030FNGA1 | Nexis GC-2030FNGA2 |
Reference Method | ASTM D1945, ASTM D3588, GPA-2261 | ASTM D1945, ASTM D3588, GPA-2261 | ASTM D1945, ASTM D3588, GPA-2261 | ASTM D1945, ASTM D3588, GPA-2261 | ASTM D1945, ASTM D3588, GPA-2261 |
Type of Detector | BID, FID | TCDx2, FID | TCD, FID | TCDx2, FID | TCD, FID |
Target Compounds | Permanent gases, C1-C5, H2S, C6+(backflush) | H2, O2, N2, CO, CO2, H2S, C1-C5, C6+(backflush) | O2, N2, CO, CO2, H2S, C1-C5, C6+(backflush) | He, H2, O2, N2, CO, CO2, H2S, C1-C5, C6+ (backflush) | O2, N2, CO, CO2, H2S, C1-C5, C6+ (backflush) |
Analysis Time | 5 minutes | 10 minutes | 10 minutes | 10 minutes | 10 minutes |
Others | Permanent gases>10 ppm, H2S>100 ppm, CH4>100 ppm, Other hydrocarbons>10 ppm, Calorific value software available |
Permanent gases>100 ppm, H2S>1000 ppm, CH4>20%, Other hydrocarbons>10 ppm, Calorific value software available |
Permanent gases> 100 ppm, H2S>1000 ppm, CH4>20%, Other hydrocarbons>10 ppm, Calorific value software available |
Permanent gases>50 ppm, H2S>500 ppm, Hydrocarbons>10 ppm, Calorific value software available |
Permanent gases>50 ppm, H2S>500 ppm, Hydrocarbons>10 ppm, Calorific value software available |
Application Datasheet | Download |
Download |
Download |
Download |
Download |
Model Name | Nexis GC-2030ENGA1 | Nexis GC-2030ENGA2 | Nexis GC-2030NGA1 | Nexis GC-2030NGA2 | Nexis GC-2030HNR1 | Nexis GC-2030HNR2 |
Reference Method | ASTM D1945, ASTM D3588, GPA-2261 | ASTM D1945, ASTM D3588, GPA-2261 | ASTM D1945, ASTM D3588, GPA-2261 | ASTM D1945, ASTM D3588 | - | - |
Type of Detector | TCDx2, FID | TCDx2, FID | TCD | TCD | FID | FID |
Target Compounds | He, H2, O2, N2, CO, CO2, H2S, C1-C14 | H2, O2, N2, CO, CO2, H2S, C1-C18 | He, H2, O2, N2, CO, CO2, H2S, C1-C5 (Better He and H2 separation) |
O2, N2, CO, CO2, H2S, C1-C5, C6+(backflush) | C1-C5 C6+(backflush) | C1-C5 C6+(backflush) |
Analysis Time | 30 minutes | 28 minutes | 23 minutes | 23 minutes | 27 minutes | 10 minutes |
Others | Permanent gases>50 ppm, H2S>500 ppm, Hydrocarbons>10 ppm, Liquified samples can be directly injected. |
Permanent gases>50 ppm, H2S>500 ppm, Hydrocarbons>10 ppm, Liquified samples can be directly injected. |
- | - | C1 is 0.01%,C2-C6 is 0.001% Packed column as main column | Hydrocarbons > 0.001% Good separation |
Application Datasheet | Download |
Download |
Download |
Download |
Download |
Download |
LPG Analysis System Lineup
Model Name | Nexis GC-2030LPGHC1 | Nexis GC-2030LPGHC2 | Nexis GC-2030DFC1 |
Type of Detector | FID | FID | FID x2 |
Target Compounds | 10 ppm for hydrocarbon C1-C6 | 10 ppm for hydrocarbon C1-C6 | 0.1 ppm to 90% for C1-C5, 0.1 ppm to 10% for Methanol, 0.1 ppm to 10% for Ethanol |
Analysis Time | 15 minutes | 15 minutes | 11 minutes |
Others | LPG is vaporized by on-line vaporizer device. | Liquid sample is measured by internal sample loop in the liquid sampling device. | Analysis of methanol and ethanol in LPG |
Application Datasheet | Download |
Download |
Download |
GC-2014 system is also available for some applications.
News / Events
-
Three Analytical and Measuring Instruments Win the Internationally Recognized “iF Design Award 2024”
The Shimadzu LCMS-2050 high-performance liquid chromatograph mass spectrometer, the Brevis GC-2050 gas chromatograph, and the ICPMS-2040/2050 ICP mass spectrometer won the internationally recognized iF Design Award 2024 in the product design category.
-
ELEM-SPOT, Element Selective Gas Chromatograph Mass Spectrometer has been released
Shimadzu’s unique ELEM-SPOT system is the world’s first Gas Chromatograph Mass Spectrometer (GC-MS) with an element-selective combustion unit (EL-30) included for selectively analyzing nitrogen-containing compounds or oxygenated compounds in complex hydrocarbon compounds with high sensitivity.
-
Ecology Simulation for GC is now available
This Simulator provides a comparison of the running cost and CO2 emissions savings between Shimadzu’s new GC models and previous conventional GC models. Replacing your Shimadzu GC with a newer model can realize savings and reduce CO2 emissions.
-
Shimadzu has released the Brevis™ GC-2050
"Smaller, simpler, and easier to use – without compromising performance." That’s the demand from analysts. And that’s why Shimadzu developed the Brevis GC-2050. This new space-saving GC delivers uncompromising analytical performance in a modern yet rugged design, easily meeting the analysis needs of laboratories in a range of industries.
-
Latest issue of Shimadzu Journal, featuring Forensics / Toxicology, has come out.
This issue focuses on "Forensics / Toxicology", an area where science and technology are particularly important and needed. It starts with two customer interviews.
-
Air
Shimadzu provides analytical equipment and solutions that can monitor not only the atmospheric environment, but also indoor working environments and direct emission sources. Here are some examples of measurements of inorganic and organic components in the air and indoor environment.