Development of New SUREengine FAST Technology for
Significant Reduction in Exposure Dose in Endoscopic
Examination of Bile and Pancreatic Ducts

SONIALVISION G4

Shimadzu Corporation has developed the new SUREengine FAST image processing technology for our SONIALVISION G4 R/F system. This technology significantly reduces the X-ray irradiation dose in endoscopic retrograde cholangiopancreatography (ERCP), which is used in the examination and treatment of bile and pancreatic ducts using endoscopes.

A pulse rate of 15 fps is used as standard with the SONIALVISION G4 in fluoroscopy during ERCP-related procedures. Comparisons made at this pulse rate has proved that the introduction of this new advanced technology enables the X-ray irradiation dose to be reduced by approx. 45% without sacrificing image quality, thereby reducing the exposure for both patients and health care providers.

Shimadzu will include this technology as standard in SONIALVISION G4 systems in future.

Background to the Development

The ERCP procedure is utilized in pancreaticobiliary duct biopsies in order to examine in detail pathological changes in pancreatic cancer and other diseases, and for treatments such as the removal of gallstones. In the ERCP procedure, an endoscope is introduced through the mouth and into the duodenum. Contrast radiography is then performed for the biliary system and pancreatic ducts directly from a narrow tube (catheter) attached to the tip of the endoscope. In this procedure, the fluoroscopic functionality of an R/F X-ray system is utilized to confirm the position of the catheter and the status of the contrast radiography. Such techniques require high-quality fluoroscopic images. However, these examinations sometimes take considerable time, so there is a need to reduce the radiation dose to which patients and health care providers are exposed.

To this end, Shimadzu has developed new digital filter processing technology for the SONIALVISION G4, our leading R/F imaging system. This technology uses high-speed computational processing to reduce image noise and lag, even at low radiation dose rates. It significantly reduces X-ray dose while maintaining excellent X-ray image quality and real-time performance required in endoscopic examinations. Our next goal is to apply this low-exposure image processing technology to the examination of nonvascular systems, not just to endoscopic examinations.

Features of the New Technology

Comparison was made at the fluoroscopic X-ray irradiation pulse rate (15 fps) used during conventional endoscopic examinations with the SONIALVISION G4, and it has shown that the introduction of the new technology enables the fluoroscopic exposure to be reduced by approx. 45%while maintaining image quality and real-time performance. Furthermore, when the pulse rate is reduced to 7.5 fps with the new technology used, the fluoroscopic exposure is reduced approx. 70% in comparison to the dose during conventional 15 fps examinations.

SONIALVISION G4 R/F System

The SONIALVISION G4 is one of our leading global models in the medical imaging diagnostic systems sector. Since its release, more than 700 of these systems have been sold on the global market, an impressive achievement. Thanks to a wealth of applications including tomosynthesis and SLOT advance (SLOT radiography), as well as introduction of technology for reducing exposure dose, it can accommodate a variety of examinations, not limited to endoscopic procedures, in a range of fields such as urology and orthopedics. In this way, it is contributing to improving the quality of healthcare in many countries all over the world.