| Item |
LC-2010CHT |
LC-2010AHT |
||
| Pump | Pump type | Serial dual plunger, micro volume (10mL on primary side, 5mL on secondary) | ||
| Flow rate setting range | 0.001 ~ 5 mL/min (1.0-35.0 MPa/145-5076psi) | |||
| Flow rate accuracy | ± 1% (1mL/min, 3.0-10.0 MPa/435-1450psi, using water, and fixed ambient temperature of 20°C , except during gradient solvent delivery), ± 2% (except for above conditions) or ± 2mL/min, whichever is greater | |||
| Flow rate precision | 0.075% RSD or 0.02min SD, whichever is greater (0.05-2ml/min, 1.0-35.0MPa/145-5076psi, methanol 20°C constant temp, ) | |||
| LPGE | Number of solvents and setting range |
Up to 4 solvents 0 to 100%, 0.1% steps |
||
| Concentration accuracy | ± 0.5% (aqueous acetone/water, binary gradient, flow rate 0.1-2.0mL/min, pressure 1.0-20.0MPa/145-2900psi) | |||
| Concentration precision | ± 0.1% (aqueous acetone/water, binary gradient, flow rate 0.1-2.0mL/min, pressure 1.0-20.0MPa/145-2900psi) | |||
| Sampler | Injection method | Variable volume injection possible (without sample loss) | ||
| Injection volume setting range | 0.1-100mL (standard), 1-2000mL (optional) (0.1 to 0.9mL in 0.1mL steps, 1 to 2000mL in 1mL steps) | |||
| Sample capacity |
1 ml vials | 350 | ||
| 1.5 ml vials | 140 | 210 | ||
| 4 ml vials | 100 | |||
| MTP | 4 96- or 384-well micro titer plates | |||
| DWP | 4 96-well deep-well plates | |||
| Injection repeatability |
RSD<0.3% (with 10mL injection) | |||
| Carry over | 0.01% (under naphthalene analysis conditions) | |||
| Injection volume accuracy | ± 1 % (50mL, n=6) | |||
| Injection volume correction | Possible | |||
| Sample cooler (LC-2010CHT) | 4 to 40°C using Peltier element | |||
| Oven | Type | Block heating/cooling with preheating of the mobile phase | ||
| Temperature control precision | ± 0.1°C | |||
| Temperature control range | (Ambient temperature -15°C) to 60°C | |||
| UV Detector | Light source | Deuterium lamp | ||
| Wavelength range | 190 to 600nm | |||
| Bandwidth | 8nm | |||
| Wavelength accuracy | ± 1nm | |||
| Wavelength precision | ± 0.1nm | |||
| Drift | 1 x 10-4 AU/h (250nm air cell) | |||
| Noise level | ± 0.25 x 10-5 AU (for response of 1s, 250nm, air cell) | |||
| Cell path length, cell volume | 10mm, 8mL (STD flow cell), 5mm, 2.4mL (semimicro flow cell) | |||
| 2 wavelengths monitoring | Any two wavelengths from 190 to 370nm or 371 to 600nm | |||
| Controller | Display | Backlit liquid crystal display (320 x 240 dots), black and white | ||
| Memory media | 3.5 inch floppy disk drive (disk format, 2HD, MS-DOS) | |||
| Input/output terminals | 2 x external inputs, 2 x external outputs, 1 x optical link (for chromatopac), 1 x | |||
| Operating temperature range | 4 to 35°C | |||
| Power requirements | AC 100V - 240V | |||
| Dimensions,Weight | W430 X D500 X H605 mm LC-2010AHT: 47kg LC-2010CHT: 52kg |
|||