Product

Laboratory Instruments

Liquid Chromatograph

Columns

High-throughput Columns

High-throughput Columns

Best Partner For High Throughput Analysis

Best Partner For High Throughput Analysis

Recently, the demand for high throughput analysis has increased. For HPLC methods, it is essential to save analysis time and to obtain reliable results. To meet such requirements, Shimadzu has developed the High Throughput (HT) column packed with very fine non-porous, high purity silica particles. With this column, it is possible to realize ultra high speed analyses (Analysis times within 1 minute.) Moreover, quality certificates for the uniformity of the packing material are provided for each column so it's easy to comply with validation requirements.
We are sure this column makes your analyses faster and more reliable.

High speed analysis

With 2um and non-porous packing material, it is possible to drastically reduce the gradient analysis run times while obtaining the same peak resolution. It is possible to finish an analysis within 1 minute. Shim-pack HT-ODS provides the capability of ultra high speed and high resolution analysis.

High speed analysis

 

Validation compliance

We certify the reliability of the analysis data with a 3 column set made from different lots and attach quality certificates for the uniformity of the packing material.

The highest performance with Shimadzu LC-2010, High-throughput HPLC

The highest performance with Shimadzu LC-2010, High-throughput HPLC

The combination of the Shim-pack HT-ODS and the Shimadzu LC-2010 is sure to help you to achieve additional high throughput in your research and analysis.

High resolution by Non-porous silica

Fig.1 Time of gradient and resolution

Fig.1 Time of gradient and resolution

Fig.1 shows the time and the resolution in gradient analyses by a column packed with porous silica and one packed with non-porous silica. Non-porous silica shows higher resolution.
The time to obtain the same resolution with a non-porous column is less than the time required when using a porous silica column.

Benefit of non-porous silica column - High speed and reliable Analysis

Fig.2 Comparison of retention time between non-porous and porous columns

Fig.2 Comparison of retention time
between non-porous and porous columns

Fig.2 shows chromatograms of gradient analyses with the same resolution by non-porous packed column and porous packed column. Non-porous column realizes high speed and reliable analysis. Non-porous silica column can save your precious time and provide you more satisfactory performance.

Specifications of column

P/N Description Dimension(mm) Notes
228-37681-91 Shim-pack HT-ODS 30 X 4.6  
228-37681-92 Shim-pack HT-ODS
(3 column kit)
30 X 4.6 A kit of columns with packings from three different production lots