GC Columns

Capillary Column

The Shimadzu offers a wide range of GC columns

High-Performance Columns

▼ Open / Close  

SH-Rxi™-5MS

SH-Rxi™-5MS Structure
  • Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane
  • Tested and guaranteed for ultra-low bleed; improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
  • General-purpose columns for semi-volatiles, phenols, amines, residual solvents, drugs of abuse, pesticides, PCB congeners (e.g., Aroclor mixes), solvent impurities.
  • Equivalent to USP G27 and G36 phases.
  • Similar phases: HP-5ms UI, HP-5ms, DB-5, Ultra-2, CP Sil 8 CB, SPB-5, Equity-5

SH-Rxi™-1HT

SH-Rxi™-1HT Structure
  • Non-polar phase: Crossbond™ 100% dimethyl polysiloxane
  • 40% longer lifetime from specially designed fused silica tubing.
  • Columns processed for high-temperature applications, such as high molecular weight hydrocarbons.
  • Similar phases: DB-1HT, AT-1ht

SH-Rxi™-5HT

SH-Rxi™-5HT
  • Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane
  • 40% longer lifetime from specially designed fused silica tubing.
  • Columns processed for high-temperature applications, such as mineral oil.
  • Similar phases: DB-5HT, VF-5HT

SH-Rxi™-5Sil MS

SH-Rxi™-5Sil MS
  • Low-polarity phase: Crossbond™ silarylene phase 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane
  • Engineered to be a low-bleed GCMS column.
  • Excellent inertness for active compounds.
  • General-purpose columns—ideal for GCMS analysis of semi-volatiles, polycyclic aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines, organochlorine pesticides, organophosphorus pesticides, drugs, solvent impurities, and hydrocarbons.
  • Similar phases: DB-5ms UI, DB-5ms, VF-5ms, SLB-5ms

SH-Rxi™-XLB

  • Low-polarity proprietary phase
  • General-purpose columns exhibiting extremely low bleed. Ideal for many GCMS applications, including pesticides, PCB congeners (e.g., Aroclor mixes), PAHs.
  • Unique selectivity.
  • Similar phases: DB-XLB, VF-Xms

SH-Rxi™-17

SH-Rxi™-17
  • Mid-polarity phase: Crossbond™ 50% diphenyl / 50% dimethyl polysiloxane
  • General-purpose columns for pesticides, herbicides, rosin acids, phthalate esters, triglycerides, sterols.
  • Similar phases: HP-17, DB-17, DB-17HT, DB-608, SPB-17

SH-Rxi™-35Sil MS

SH-Rxi™-35Sil MS
  • Mid-polarity: Crossbond™ phase (similar to 35% phenyl methyl polysiloxane)
  • Very low-bleed phase for GCMS analysis.
  • Special selectivity and excellent inertness for substituted polar compounds, such as drugs, pesticides, herbicides, PCBs, phenols, etc.
  • Provides superior separation for cannabinoids.
  • Similar phases: DB-35ms, DB-35ms UI, VF-35ms

SH-Rxi™-17Sil MS

SH-Rxi™-17Sil MS Structure
  • Mid-polarity Crossbond™ phase (similar to 50% phenyl methyl polysiloxane)
  • Low bleed for use with sensitive detectors, such as MS.
  • Excellent inertness and selectivity for active environmental compounds, such as PAHs.
  • Equivalent to USP G3 phase.
  • Similar phases: DB-17ms, HP-17, DB-17, VF-17ms, CP-Sil 24 CB

SH-Rxi™-PAH

  • Mid-polarity proprietary phase
  • Ideal for EFSA PAH4 analysis—separates all priority compounds: benz[a]anthracene, chrysene, benzo[b]fluoranthene and benzo[a]pyrene.
  • Best resolution of chrysene from interfering PAHs, triphenylene, and cyclopenta[cd]pyrene.
  • Complete separation of benzo [b], [k], [j], and [a] fluoranthenes.

SH-Rxi™-624Sil MS

SH-Rxi™-624Sil MS Structure
  • Mid-polarity Crossbond™ silarylene phase (similar to 6% cyanopropylphenyl / 94% dimethyl polysiloxane)
  • Low-bleed, high-thermal stability column—maximum temperatures up to 300–320 °C.
  • Inert—excellent peak shape for a wide range of compounds.
  • Selective—G43 phase highly selective for volatile organics and residual solvents, great choice for USP<467>.
  • Manufactured for column-to-column reproducibility—well-suited for validated methods.
  • Similar phases: HP-624, DB-624, VF-624ms, CP-Select 624 CB

SH-Rxi™-1301Sil MS

SH-Rxi™-1301Sil MS Structure
  • Mid-polarity Crossbond™ silarylene phase (similar to 6% cyanopropylphenyl / 94% dimethyl polysiloxane)
  • Highest thermal stability in the industry ensures dependable, accurate MS results and increased uptime.
  • Stabilized cyano phase selectivity improves the performance of existing methods. Ideal for solvents, glycols, and other polar compounds.
  • Rigorous QC testing ensures inertness and accurate, reliable data for multiple compound classes.
  • Similar phase: VF-1301ms

General-Purpose Columns

▼ Open / Close  

Dedicated Columns

▼ Open / Close  

PLOT Columns

▼ Open / Close  

Metal Columns

▼ Open / Close  

Guard Columns

▼ Open / Close  

SH-Rxi™ Guard / Retention Gap Columns

  • Extend column lifetime.
  • Excellent inertness-obtain lower detection limits for active compounds.
  • Sharper chromatographic peaks by utilizing retention gap technology.
  • Maximum temperature: 360 °C.
ID 5 m 10 m
0.25 mm 227-36303-01 227-36304-01
0.32 mm 227-36305-01 227-36306-01
0.53 mm 227-36307-01 227-36308-01

SH-Particle Trap (for PLOT columns)

  • Includes two Press-Tight® connectors and a 2.5 m column.
  • Protects detector and valves; connects between column and detector or valve.
  • Eliminates detector spikes and scratches in valve rotors.
Description P/N
SH-Particle Trap for 0.32 mmID PLOT Columns 227-36800-01
SH-Particle Trap for 0.53 mmID PLOT Columns 227-36800-02

Integra-Guard™ Columns

  • No leaks for a more robust method.
  • No column connections for easier, faster maintenance.
  • No peak distortions due to connector dead volume and thermal capacity.
Integra-Guard™ Columns
Column ID df Length With 5 m
Integra-Guard™
With 10 m
Integra-Guard™
SH-Rxi™-5Sil MS 0.25 mm 0.25 μm 30 m 221-76161-30 221-76162-30
SH-Rtx™-1  0.25 mm 0.25 μm 30 m 221-75719-31 -
0.53 mm 1.00 μm 30 m 221-75731-31 -
0.53 mm 5.00 μm 30 m 221-75734-31 -
SH-Rtx™-5 0.25 mm 0.25 μm 30 m 221-76153-05 221-76153-30
0.25 mm 1.00 μm 30 m 221-76179-30 -
0.32 mm 0.25 μm 30 m 221-76177-30 -
0.32 mm 0.25 μm 60 m 221-76177-60 -
0.32 mm 1.00 μm 30 m 221-76180-30 -
0.53 mm 5.00 μm 30 m 221-76154-35 -
SH-Rtx™-5MS 0.25 mm 0.10 μm 30 m 221-76189-30 -
0.25 mm 0.25 μm 15 m 221-75861-15 -
0.25 mm 0.25 μm 30 m 221-75861-05 221-75861-10
0.32 mm 0.25 μm 30 m 221-76190-30 -
SH-Rtx™-1301 0.53 mm 3.00 μm 30 m 221-76164-35 -
SH-Rtx™-624 0.25 mm 1.40 μm 30 m 221-76183-30 -
0.32 mm 1.80 μm 30 m 221-76157-35 -
0.53 mm 3.00 μm 30 m 221-76158-30 -
SH-Rtx™-1701 0.25 mm 0.25 μm 30 m 221-76185-30 -

Brochure download

Download the latest brochure.

Brochure 

For Research Use Only. Not for use in diagnostic procedures.

This page may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country.