GC Driver for OpenLAB CDS EZChrom Edition Ver. 2

Product Lineup

# Description Versions with Functionality Verified
1 Shimadzu GC Driver Single for OpenLAB CDS 2
OpenLAB
2.1 / 2.2 / 2.3
2
Shimadzu GC Driver Single for OpenLAB CDS EZChrom Edition
OpenLAB CDS EZChrom Edition
A.04.06, A.04.07, A.04.08, A.04.09

* The same product is used both for standalone and network versions of OpenLAB systems.
* To install the driver in an existing OpenLAB system, please inform us of the software version and other relevant information in advance.

Controllable Hardware

GC units: Nexis GC-2030, GC-2010 Plus, GC-2010, GC-2014
Options: AOC-20i (Plus) autoinjector, AOC-20s autosampler, HS-20/HS-10 headspace sampler, dual injection system

Nexis GC-2030

Sample Injector SPL-2030, WBI-2030, OCI-2030, PTV-2030
Detector FID-2030, TCD-2030, ECD-2010 Exceed, FPD-2030, FTD-2030, BID-2030, SCD-2030
Advanced Flow Technology Backlash, detector splitting, detector switching, heart-cut system
Additional temperature controller APC (3 auxiliary channels), APC (1 auxiliary channel)
Options Low-temperature control solenoid valve set: CRG-2030
External equipment control relay: PRG-2010 Plus, PRG Box

GC-2010 (Plus), GC-2014

Sample Injector GC-2010 (Plus): SPL-2010 (Plus), WBI-2010 (Plus), OCI / PTV-2010
GC-2014 : SPL-2014, WBI-2014, DINJ-2014, SINJ-2014
Detector GC-2010 (Plus): FID-2010 (Plus), TCD-2010 (Plus), ECD-2010 Exceed, ECD-2010 (Plus),
                         FPD-2010 (Plus), FTD-2010 (Plus), BID-2010 Plus
GC-2014          : FID-2014, TCD-2014, ECD-2014, FPD-2014, FTD-2014 (C)
Additional temperature controller Auxiliary temperature control unit
Additional flow controller APC (3 auxiliary channels), AMC (2 auxiliary channels) Note: AMC is an option for the GC-2014.
Options Low-temperature control solenoid valve set: CRG-2010
External equipment control relay: PRG-2010 (Plus), PRG Box

* Up to four Shimadzu GC units can be controlled from a single computer or acquisition server (such as an AIC).

* Both the Shimadzu GC driver and Shimadzu LC driver can be installed on the same computer or acquisition server (such as an AIC).

*A Shimadzu GC system and Agilent GC system cannot be connected to the same computer or acquisition server (such as an AIC) at the same time. Please provide a dedicated data acquisition server for the Shimadzu GC system.

 

Nexis and AOC are trademarks of Shimadzu Corporation.
OpenLAB is either a registered trademark or a trademark of Agilent Technologies, Inc in the United States and/or other countries.
 

For Research Use Only. Not for use in diagnostic procedures.

This page may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country.