Nexera Method Scouting System

Ultra High Performance Liquid Chromatograph Method Scouting System

Analysis conditions settings > Analysis

Easy selection of mobile phases and columns from libraries

The columns and mobile phases used for method scouting are controlled in a database. During analysis, they are easily selected via a graphical user interface. The names of the selected columns and mobile phases can be reflected in analysis reports. This consolidates notation for the names of the columns and mobile phases used in the laboratory, preventing mistakes with respect to important column and mobile phase conditions when reviewing scouting results.

Easy selection of mobile phases and columns from libraries

Simple gradient pattern settings

Basic configuration of the Nexera Method Scouting System

The Nexera Method Scouting System achieves stable data acquisition by adopting the newly developed FCV-34AH (100 MPa pressure resistance) high-pressure-resistant column switching valve and manifold. In addition, with auto-purging, mobile phase equilibration times are reduced by purging the mobile phase inside the autosampler, which means a faster method scouting workflow.

Basic configuration of the Nexera Method Scouting System

Enabling graphical display of column connections

Column connections interlinked with the graphical user interface

Achieving automation of laboratory operations

Mobile phase purge conditions and equilibration when automatically switching mobile phases and columns are key issues in method scouting. With Method Scouting Solution, scouting reflects laboratory operations, thanks to automatic control of mobile phase purging and equilibration based on preset system configurations.

System confirmation and recording
Data is recorded on system maintenance status prior to scouting, which is useful for reviews if problems with data occur.

Mobile phase purging
Auto-purge timing is configured. The system performs mobile phase purging automatically based on the conditions configured here, achieving fast mobile phase switching.

System equilibration determination
Auto-purge timing is configured. The system performs mobile phase purging automatically based on the conditions configured here,supporting reliable data acquisition

Scouting scheme
Scouting schemes can be set to give priority to columns or mobile phases
based on laboratory policy.

For Research Use Only. Not for use in diagnostic procedures.