Solvent Delivery Unit

Part Name
Description
Low-pressure gradient unit Low-pressure gradient unit for LC-40D/40D XR/40D XS/40D X3
Reservoir selection valve Two-solvent switching unit to be incorporated in solvent delivery unit
FCV-11AL The mobile phase switching valve of 3 flow lines that connects to solvent delivery unit (external)
FCV-11ALS The mobile phase switching valve of 1 flow line that connects to solvent delivery unit (external)
Automatic rinsing kit Automatic rinsing kit for plunger seal cleaning
Mixer MR 20 μL High-efficiency mixer for high-pressure gradient system (volume 20 μL)
Mixer MR 40 μL High-efficiency mixer for high-pressure gradient system (volume 40 μL)
Mixer MR 100 μL High-efficiency mixer for high-pressure gradient system (volume 100 μL)
Mixer MR 180 μL High-efficiency mixer for high-pressure gradient system (volume 180 μL)
Mixer MR 40 μL LPGE
High-efficiency mixer for high-pressure gradient system (volume 40 μL)
Mixer MR 300 μL LPGE High-efficiency mixer for high-pressure gradient system (volume 300 μL)

Autosampler

Part Name Description
Sample loop 50 μL Sample loop for 50 μL injection (standard configuration of SIL-40 XR/40C XR/40C XS/40C X3)
100 μL Sample loop for 100 μL injection (standard configuration of SIL-40/40C)
500 μL
 
Sample loop to increase the injection volume up to 500 μL
(Connect sample loop 100 μL)
2000 μL Sample loop to increase the injection volume up to 2 mL
(Connect sample loop 100 μL)
Dual-injection kit Tubing kits for dual injection 
Sample loop for
loop injection
5 μL Sample loop for loop injection mode (volume 5 μL)
20 μL Sample loop for loop injection mode (volume 20 μL)
50 μL Sample loop for loop injection mode (volume 50 μL)
1.5 mL Plate for 1.5 mL sample vial (54)
Sample plate 1 mL Plate for 1 mL sample vial (84)
4 mL Plate for 4 mL sample vial (28)
10 mL Plate for 10 mL sample vial (12)
Identification
labels
For 96-well
microplates
Identification label affixed to the 96-well microtiter plate (100 set)
For 96-well
deep-well plates
Identi‰cation label affixed to the 96-well deep-well plate (100 set)
For 384-well
microplates
Identi‰cation label affixed to the 384-well microtiter plate (100 set)
For 384-well
deep-well plates
Identification label affixed to the 384-well deep-well plate (100 set)

Column Oven

Part Name Description
Active pre-heater Pre-heater device for thermostatting mobile phase before the column inlet
Nexlock™ SS ID 0.1 mm×600 mm Finger-tight high-pressure fitting
ID 0.3 mm×600 mm

UV Detector / PDA Detector

Part Name Description
UHPLC cell Flow cell for high-speed analysis (volume 8 μL)
Semi-micro cell Flow cell for semi-micro analysis (volume 2.5 μL)
Conventional cell Flow cell with the same cell volume (12 μL) as standard cell of SPD-20A and SPD-M20A
Inert cell Inert-type flow cell with metal-less wetted parts
Preparative cell Preparative flow cell with variable optical path length
Micro flow cell Flow cell for micro analysis (volume 0.21 μL)
Maximum pressure cell High-pressure resisting flow cell for Nexera™ UC
Solvent recycle valve Valve to recycle mobile phase by attaching to SPD-40/40V

Others

Part Name Description
Mobile phase monitor (controller)
MPM-40 controller to monitor remaining mobile phase in real-time
Up to six bottle holders can be connected
Reservoir tray Reservoir tray for up to 8 bottles (1L)
AD board Board for analog–digital conversion. It takes in detector signals as analog signals.
Optical cable connector
expansion board
The board to expand the number of optical cable connector channels to 12ch from 8ch
(standard) by attaching to SCL-40/CBM-40
 

Valve

 
Part Name Description
FCV-DR Drive unit and control board for incorporating valve into CTOs (1 FCV valve is required separately)
FCV-0206 2-position 6-port valve (Maximum pressure: 44 MPa)
FCV-0607 6-position 7-port valve (Maximum pressure: 44 MPa)
FCV-0206H 2-position 6-port valve (Maximum pressure: 80 MPa)
FCV-0607H 6-position 7-port valve (Maximum pressure: 80 MPa)
FCV-0206H3 2-position 6-port valve (Maximum pressure: 130 MPa)
FCV-0607H3 6-position 7-port valve (Maximum pressure: 130 MPa)6