Nexera series lite

 

 

A conventional HPLC model with excellent basic functions and many options for expansion. Cutting-edge AI functions increase the reliability of established analysis workflows. It can be adapted for all application systems.

 Nexera lite High Pressure Gradient 
  Model Name Features
System controller SCL-40 Color screen with touch panel and system controller with reservoir tray
Number of connectable units : 8 (Using option: 12)
Connectable unit : Solvent delivery unit: max. 4, Autosampler: 1, Column oven: max. 4, Detector: max 2, etc.
Solvent Delivery Pump LC-40D (2pcs)
Pumping method : Parallel-type double plunger (approx. 10 μL/1 stroke)
Allowable maximum pressure : 44 MPa
Flow rate settings range : 0.0001 – 5.0000 mL/min (1.0 – 44 MPa)
5.0001 – 10.0000 mL/min (1.0 – 22 MPa)
Flow rate accuracy :  ≦± 1% or ± 2 μL/min, whichever greater
(under specified conditions)
Gradient mode : High-pressure gradient (2 or 3 solvents) Quaternary low-pressure gradient
Gradient Mixer
Degassing Unit DGU-403 Number of degassed solvents : 3
Degassed flow line capacity : 400 μL/1 line
Operating temperature range : 4 to 35°C
Autosampler SIL-40C
Injection method : Total-volume Injection (standard), loop injection (optional)
Allowable maximum pressure : 44 MPa
Injection volume : 0.1 to 100 μL, 0.1 to 2000 μL (optional)
Injection volume accuracy :  ≦± 1% (5 μL injection, n = 20)
Injection cycle time :  ≦6.7 seconds (under specied conditions)
Column Oven CTO-40C Temperature control type : Forced air circulation
Cooling Method : Electronic cooling
Temperature control range : Room temperature − 10°C to 100°C
Temperature accuracy : ± 0.5°C
Temperature precision : ± 0.05°C
UV-VIS Detector SPD-M40 Light source : Deuterium (D2) lamp
Number of diode elements : 1024
Wavelength range : 190 to 700 nm
Wavelength accuracy : ≦± 1 nm
Wavelength reproducibility :  ≦± 0.1 nm
Mobile phase monitor
Software Labsolutions LC/GC Multi LC-PDA


 
 
 Nexera lite Low Pressure Gradient 
  Model Name Features
System controller CBM-40 Monitor : LabSolutions Web monitor
Connectable unit : Solvent delivery unit: max. 4, Autosampler: 1, Column oven: max. 4, Detector: max 2, etc.
Number of connectable units : 8 (Using option: 12)
Solvent Delivery Pump LC-40D
Pumping method : Parallel-type double plunger (approx. 10 μL/1 stroke)
Allowable maximum pressure : 44 MPa
Flow rate settings range : 0.0001 – 5.0000 mL/min (1.0 – 44 MPa)
5.0001 – 10.0000 mL/min (1.0 – 22 MPa)
Flow rate accuracy :  ≦± 1% or ± 2 μL/min, whichever greater(under specified conditions)
Gradient mode : High-pressure gradient (2 or 3 solvents Quaternary low-pressure gradient
Gradient Mixer
Degassing Unit DGU-405 Number of degassed solvents : 5
Degassed flow line capacity : 400 μL/1 line
Operating temperature range : 4 - 35°C
Autosampler SIL-40C
Injection method : Total-volume Injection (standard), loop injection (optional)
Allowable maximum pressure : 44 MPa
Injection volume : 0.1 to 100 μL, 0.1 - 2000 μL (optional)
Injection volume accuracy : ≦± 1% (5 μL injection, n = 20)
Injection cycle time : ≦6.7 seconds (under specified conditions)
Column Oven CTO-40S Temperature control type : Forced air circulation
Cooling Method : Electronic cooling
Temperature control range : Room temperature ― 10°C - 85°C
Temperature accuracy : ± 0.8°C
Temperature precision : ± 0.1°C
UV-VIS Detector SPD-M40 Light source :Deuterium (D2) lamp, Tungsten lamp
Number of diode elements : 1024
Wavelength range : 190 - 800 nm
Wavelength accuracy :  ≦± 1 nm
Wavelength reproducibility :  ≦± 0.1 nm
Mobile phase monitor
Software Labsolutions LC/GC Multi LC-PDA


 
 

For Research Use Only. Not for use in diagnostic procedures.

This page may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country.