Nexera Mikros

Columns for Microflow Analysis

Shim-pack™ MC C18

Shim-pack™ MC C18

Versatility

  • Shim-pack MC C18 column with 1.9 μm UHPLC particle achieves excellent separation and peak shape.
  • The high pressure rating of 70 MPa allows these columns to be compatible with a range of mobile phase flow rates from 1 to dozens of μL per minute.
  • The metal coordinative adsorption is suppressed by deactivating the column parts in contact with the solution.
  • Both small and large molecule compounds, such as peptides, can be analyzed.
  • Excellent durability can be achieved even if the biological sample analysis.

Shim-pack™ MC C18 

Shim-pack MC PLONAS Series

Shim-pack MC PLONAS Series

Superior Performances with Superficially Porous Particles (SPP)

  • Shim-pack MC PLONAS 2.7 μm columns reduce the back pressure yet maintain the performance of a sub 2 μm fully porous particle column. The pressure limit is 40 MPa.
  • Achieve lower LODs and LOQs, better resolution, and greater reproducibility using the unique superficially porous particle found in Shim-pack MC PLONAS.
  • Greater dimensional offerings allows for higher efficiency with better resolving power for challenging applications.
  • An array of pore sizes designed to meet the needs of any application.
  • Increased ruggedness because of larger porosity frits resulting in less clogging compared to competitor columns.
  • Excellent column-to-column and lot-to-lot reproducibility.
 

Shim-pack MC PLONAS Series 

Shim-pack Trap Columns

 

Trap Columns Wide Portfolio

  • Shim-pack MCT C18/C8
    70 MPa pressure limitation and a unique modification on the column inner surface protects against absorption of the molecule.

    Shim-pack MCT series 

  • Shim-pack MCT LC18/LC8
    A small-volume cartridge column with 40 MPa pressure limit. Useful in reducing the gradient delay for a low flow rate.

 

Shim-pack Trap Columns

 
 

 

Shim-pack MCT series
P/N Bonded Phase Diameter (mm) Length (mm)
228-59938-91
 
 
C18
0.3
 
 
 
35
228-59938-92 0.5
228-59939-91
 
 
C8
0.3
 
 
35
228-59939-92 0.5

 

Shim-pack MCT L series (particle size 5 μm)
P/N Bonded Phase Diameter (mm) Length (mm)
227-32701-01
 
 
Trap column holder for Shim-pack MCT L
227-32702-01 C18 0.3
 
 
5
227-32703-01 C8 0.5
 

Nexera Mikros: Trap and Elute Configuration

The trap and elute system can be constructed by using a dedicated piping kit (228-71751-42).

Trap and Elute Configuration

For Research Use Only. Not for use in diagnostic procedures.

This page may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country.