Column Switching LC/MS/MS Method using Methylcellulose Immobilized Column for Quantitation of Triclosan and Triclocarban in wastewater

Triclosan and triclocarban are antimicrobials currently added to a large number of consumer’s products including household soaps, deodorants, toothpastes, mouth washes, and cleaning agents. These chemicals are the potential to cause a number of environmental and human health problems.
In this study, an on-line column switching pre-concentration method has been applied to extract triclosan, triclosan-methyl, and triclocarban in water samples. The pre-extracted chemicals were quantified using LC/MS/MS with large volume injection.

Content Type:
Paper
Document Number:
PO-CON1373E
Product Type:
Liquid Chromatography, Liquid Chromatograph-Mass Spectrometry, Mass Spectrometry
Keywords:
triclosan, triclocarban, antimicrobials, wastewater, Environment, Hydrocarbon Processing Industry (Petrochemical, Chemical), Discharge Water, Groundwater, Environment Water, LCMS-8040
Language:
English
File Name:
jpo113112.pdf
File Size:
233kb

Free Download

For Research Use Only. Not for use in diagnostic procedures.

This page may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country.