UV accessory selection guide for solids

Solid Samples

Sample Analytical form and analytical condition Accessory
Smooth Surface Samples* Transmittance Measurement Less than 3 mm thick Standard compartments+Film Holder, Cell Type Sample Holder, Glass/Film Holder for Standard Sample Compartment
More than 3 mm thick Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
Requires a large integrating sphere
(due to ISO compliance and other reasons).
Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
Large sample size (over 100 mm square) Large-Sample Compartment (MPC-2600A/603A or SolidSpec-3700) Glass Sample Holder for MPC series/SolidSpec
Reflectance Measurement Relative Specular Reflectance Measurement Normal measurement Specular Reflectance Measurement Attachment (5° incident angle)
Large sample size (over 100 mm square) SolidSpec-3700 + Large Specular Reflectance Measurement Attachment (5° incident angle)
Absolute Specular Reflectance Measurement 5゚ incident angle measurement Absolute Specular Reflectance Attachment (ASR-3105) (Requires a Large-Sample Compartment and
BIS-3100/3700/603 Sample Base Plate Integrating Sphere Set separately).
12/30/45゚ incident angle measurement Absolute Specular Reflectance Attachment (ASR-3112, ASR-3130, ASR-3145) (Requires a Large-Sample
Compartment, BIS-3100/3700/603 Sample Base Plate Integrating Sphere Set, and polarizer assembly separately.)
Variable Angle Measurement Unit Variable Angle Measurement Unit (Requires large-sample compartment and polarizer assembly separately.)
Relative Diffuse Reflectance Measurement Normal measurement Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
Requires a large integrating sphere
(due to ISO compliance and other reasons).
Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
Large sample size (over 100 mm square) Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700)
Rough Surface Sample** Transmittance Measurement Normal measurement Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
Requires a large integrating sphere
(due to ISO compliance and other reasons).
Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
Large sample size (over 100 mm square) Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700)
Reflectance Measurement Relative Diffuse Reflectance Measurement Normal measurement Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603)
Requires a large integrating sphere
(due to ISO compliance and other reasons).
Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F)
Large sample size (over 100 mm square) Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700)
Absolute Diffuse Reflectance Measurement Consult your Shimadzu representative.
(Depends on the sample. A method using conversion from the mirror reflectance, for instance, is available.)
Large sample size (over 100 mm square) Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700)
Small sample size (below 5 mm square) Micro Sample Holder + Micro Beam Lens Unit

* Metals with a mirror-finished surface, mirrors, transparent acrylic and films, etc.
** Paper, cloth, plastics, semi-transparent films, etc.

For color measurement, the Color Measurement Software COL-UVPC is required separately.
For film thickness measurement, the Film Thickness Measurement Software FLM-UVPC is required separately.

For Research Use Only. Not for use in diagnostic procedures.