inspeXio SMX-225CT FPD Plus - Specs

Microfocus X-Ray CT System

inspeXio SMX-225CT FPD HR

Target object

Aluminum die castings, electronic circuit boards, electronic parts, composite materials, etc.

Max. sample size

Max. 400 mm dia. × H300 mm Max. 350 mm dia. × H300 mm

Max. sample weight

Max. 12 kg

X-ray detector

16-inch flat panel detector

Max. field of view

400 mm dia.

Read more
Show Less

inspeXio SMX-225CT FPD

Target object

Aluminum die castings, electronic circuit boards, electronic parts, composite materials, etc.

Max. sample size

Max. 350 mm dia. × H300 mm

Max. sample weight

Max. 9 kg

X-ray detector

8-inch flat panel detector

Max. field of view

250 mm dia.

Read more
Show Less

inspeXio SMX-225CT FPD Plus

X-Ray Generator : Rated Power

135 W

Scan Support Functions : 3D CT Scan Region Display Function

Yes

Power Requirements : Ground

Type-D ground (100 ohm max. ground resistance)

Power Requirements : Control Computer

100 V AC ±10 %, 50/60 Hz, 1 kVA

Power Requirements : Main Unit

200 V AC ±10 %, 50/60 Hz, 3 kVA

Specialized Desk Size and Mass

W1,200 × D700 × H1,270 mm, approx. 50 kg

Shield Box Size and Mass

W2,170 × D1,350 × H1,857 mm, approx. 3,100 kg

CT Data Acquisition Time

Any value from 10 sec to 60 min

Scan Modes

Normal scan, half scan, offset scan, FS scan*1, 2DCT*2, CBCT*3

Scan Support Functions : Fully Automatic CT Scanning

Yes

Scan Support Functions : Positioning via an exterior camera

Yes

X-Ray Generator : Max. Tube Voltage

225 kV

Max. CT Image Size : Cone-Beam CT

4,096 × 4,096

Max. CT Image Size : Two-Dimensional CT

4,096 × 4,096

Max. sample weight

9 kg

Max. Sample Size and CT-Scan Region

Max.Sample Size 350mm dia.H300mm
Max.CT-Scan Region 250mm dia.H300mm

Max. Input Resolution (for offset scan)

Approx. 1,800,000 pixels

X-Ray Detector Shades of Gray

14-bit = 16,384 shades of gray

X-Ray Detector Size

8 inch

X-ray detector

Flat panel detector

External Leakage Dose

1 μSv/h max.

*1 FS scan : The fan-shaped (FS) scan obtains CT images by scanning the sample at 60, 90, and 120 degree rotation angles.
*2 2DCT : Two-dimensional computed tomography (2DCT) obtains one or three CT images from each CT scan.
*3 CBCT : Cone beam computed tomography (CBCT) obtains several hundred CT images from each CT scan.

Read more
Show Less
{"title":"Specification Sheet Downloads","description":"Download the latest specification sheets.","source":"product","key":3491,"max":"30","filter_types":["spec_sheet"],"link_title":"View other Downloads","link_url":""} {"title":"Downloads","description":"Download the latest brochure.","source":"product","key":3491,"max":"30","filter_types":["brochures"],"link_title":"View other Downloads","link_url":"","pdf_links":[]}