Application News No. G319 Gas Chromatography Example of Analysis of Moisture in Nitrogen Using Highly Sensitive Trace Moisture Analysis System The Shimadzu highly sensitive trace moisture analysis system is a dedicated system GC for moisture analysis using a Nexis™ GC-2030 equipped with Shimadzu proprietary high- sensitivity detector, BID (barrier discharge ionization detector), and a combination of an ionic liquid capillary column and a dedicated sampling valve. These features enable highly accurate measurement of trace moisture in gases at the ppm level. In this experiment, moisture present at a low concentration moisture in a standard gas was analyzed by using the highly sensitive trace moisture analysis system. R. Takechi, Y. Takemori Highly Sensitive Trace Moisture Analysis System Fig. 1 shows the appearance of the highly sensitive trace moisture analysis system. In the past, high-sensitivity analysis of moisture by GC was considered to be extremely difficult due to two main reasons, namely, the lack of a column capable of selective separation of water and the lack of a detector that could detect water with high-sensitivity. However, more accurate quantitation of the moisture component than with conventional methods such a Karl Fischer titration is now possible by using an ionic liquid capillary column in combination with a BID. Fig. 1 Highly Sensitive Trace Moisture Analysis System Composition of Highly Sensitive Trace Moisture Analysis System ① Dedicated sampling system In sample injection using a syringe, the analysis is affected by trace moisture in the atmosphere. Therefore, in this system, a dedicated gas sampling system is used in place of a sample injection unit. Injection of an accurate amount of gas into the GC is possible by using this gas sampling system. ② Ionic liquid capillary column (Watercol™: Sigma-Aldrich) Ionic liquids are liquids that consist of only ions and salts that have melting points of no more than approximately 100 °C. These liquids have the following distinctive features when used as the liquid phase of a column. • Low column bleed • High maximum use temperature • Durability against moisture and oxygen This column system enables measurement of moisture at low concentration levels which had been considered impossible in the past. In particular, although impurities had also been detected as moisture in conventional moisture measurement technologies not accompanied by separation, this system can realize high-sensitivity/accuracy quantitation by separation, utilizing its strong point as a chromatograph. ③ BID (barrier discharge ionization detector) BID is a universal detector that includes a photoionization technique using low-frequency dielectric barrier discharge plasma and offers high-sensitivity analysis. This new Shimadzu proprietary and general-purpose detector is capable of ionizing and detecting virtually all compounds except helium and neon with higher-sensitivity than other general-purpose detectors such as TCD and FID. Instrument Composition and Analysis Conditions Table 1 shows the instrument composition and analysis conditions. It should be noted that this system is a special order product. Table 1 Analysis Conditions GC model : Nexis GC-2030 Injection system : Dedicated sampling system (valve with helium purge function) Injection mode : Split (splitter injection) Injection volume : 1 mL (Sulfinert-type piping) Carrier gas : He (helium purifier: HP2 connection) Split ratio : 1 : 20 Purge flow : 3 mL/min Carrier gas control : Linear velocity 40 cm/s (column flow rate: 1.77 mL/min) Column : Watercol-1910 (0.25 mm I.D. × 30 m, d.f. = 0.20 μm) Column temp. : 120 °C Detector : BID-2030 Detector temp. : 150 °C Detector gas : He 50 mL/min ① ② ③
First Edition: Apr. 2020 For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. Shimadzu disclaims any proprietary interest in trademarks and trade names used in this publication other than its own. See http://www.shimadzu.com/about/trademarks/index.html for details. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. © Shimadzu Corporation, 2020 www.shimadzu.com/an/ Application News No. G319 Analysis of Standard Gas (Moisture in N 2 ) The calibration curve was prepared by the absolute calibration curve method using nitrogen standard gas containing approximately 5 ppm, 25 ppm, or 100 ppm of moisture. Fig. 2 shows the chromatogram, Fig. 3 shows the calibration curve, and Table 2 shows the peak area and repeatability (N = 5) at each moisture concentration level. Although trace moisture analysis by GC had been considered difficult until now, a trace moisture analysis was carried out at the ppm level, and good separation, linearity, and repeatability were obtained. The peak of water separated by the ionic liquid capillary column was sharper than those obtained with conventional columns and could also be obtained without tailing. Under these analysis conditions, a shorter analysis cycle time was achieved by setting a constant oven temperature (120 °C) without GC oven cooling time. (Although a sharper peak shape is possible by programmed temperature GC, the analysis cycle time becomes long.) Fig. 2 Chromatogram of Nitrogen Standard Gas Containing Trace Moisture Fig. 3 Calibration Curve Table 2 Peak Area and Repeatability at Each Moisture Concentration Moisture concentration (ppm) 5.994 24.44 109.3 Peak area 1 42431 85912 272693 Peak area 2 43249 85077 274031 Peak area 3 42832 83731 272912 Peak area 4 42395 82438 274313 Peak area 5 42373 82360 272680 Average peak area 42656 83904 273326 %RSD 0.894 1.881 0.287 Nexis is a trademark of Shimadzu Corporation in Japan and/or other countries. Watercol is a trademark of Sigma-Aldrich Co LLC. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “£”. Water N 2 5.994 ppm (S/N ratio : 851) 25.44 ppm (S/N ratio : 1969) 109.3 ppm (S/N ratio : 6106) 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 min 0.0 25.0 50.0 75.0 100.0 Concentration 0 25000 50000 75000 100000 125000 150000 175000 200000 225000 250000 275000 Peak area 1 2 3 R 2 = 0.9999
Related Products Some products may be updated to newer models. Trace Moisture Analysis System Price Inquiry Product Inquiry Technical Service / Support Inquiry Other Inquiry Powered by TCPDF (www.tcpdf.org)