Content overflows the browser. Try zooming out (Ctrl + −) to see the full page. PDF Download
Application News No. M283 Gas Chromatography Mass Spectrometry Analysis of Bile Acid by GC-MS LAAN-A-MS-E047 With active research on intestinal flora, analysis of the components produced by intestinal flora, which include bile acids, has attracted attention. “Bile acid” is a generic term for compounds having a cholanic acid skeleton, which is a steroid derivative. In general, LC-MS/MS is frequently used in analyses of bile acid, but because many of the individual compounds have similar molecular structures, GC- MS is also used in many cases when more reliable separation is required. In order to secure volatility in GC-MS analyses of bile acid, derivatization of hydrophilic side chains such as the carboxyl group and hydroxy group is necessary. This article introduces an example of quantitative analysis of bile acid by methylation of the carboxyl group and trimethylsilylation (TMS) of the hydroxy group. In this example, a dynamic range of 100 times or more and good linearity with a coefficient of determination R 2 ≥ 0.995 were confirmed in all of 22 bile acid compounds. T. Sakai Bile Acid Structure and Derivatization Bile acid compounds cannot be analyzed by GC-MS without pretreatment due to their comparatively large molecular weight and their low volatility owing to the presence of hydrophilic residues. Derivatization of these hydrophilic residues is necessary for GC-MS analysis. The important residues in bile acids are the hydroxy group and carboxyl group, and at least these groups must be derivatized by substituting different residues. Fig. 1 Structure of Cholic Acid (Bile Acid Compound) Where Three Hydroxy Groups and One Carboxyl Group Exist in One Molecule. Fig. 2 Schematic Diagram of Derivatization with Trimethylsilylation of Hydroxy Groups, Methylation of Carboxyl Group. Derivatization of both hydrophilic residues, that is, the hydroxy groups and the carboxyl group, is generally possible by trimethylsilylation, but the derivative compounds are unstable in bile acids. Therefore, in this paper, we adopted a derivatization method consisting of methylation of the carboxyl group, followed by trimethylsilylation of the hydroxy groups. Fig. 3 shows the details of the pretreatment protocol. Fig. 3 Derivatization Protocol for Bile Acid Measurement of Derivatized Bile Acid The derivatized bile acid described above was analyzed with a GC-MS. The analysis conditions are shown below. Table 1 Measurement Conditions GC-MS : GCMS-QP™2020 NX Column : DB-5MS (30 m × 0.25 mm, 0.25 μm) GC Injection mode : Splitless Vaporizing chamber temp. : 310 °C Column oven temp. : 230 °C (2 min) → (8 °C -/min) → 310 °C (5 min) Control mode : Linear velocity (45.3 cm/s) Purge flow rate : 3.0 mL/min MS Measurement mode : Scan or SIM (Scan range: m/z 35-700) Ion source temp. : 200 °C Interface temp. : 280 °C Event time : 0.3 s Trimethylsilylation OH O Si CH3 CH3 CH3 Methylation OH O CH3 C O C O Take a fixed quantity of a bile acid standard solution of known concentration with a micropipette, and vaporize the solvent completely with a centrifugal concentrator. [Methylation] After sufficiently mixing 20 μL of methanol, 80 μL of benzene, 50 μL of TMS diazomethane (approx. 10% hexane solution), vaporize completely by N2 purge in a draft. [Trimethylsilylation] Add 25 μL of pyridine and 5 μL of trimethylchlorosilane (TMCS) to 50 μL of N-trimethylsilylimidazole (TMSI), and treat at 60 °C for 10 min. Introduce into a vial and inject into the GC-MS.
First Edition: Nov. 2019 For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. Shimadzu disclaims any proprietary interest in trademarks and trade names used in this publication other than its own. See http://www.shimadzu.com/about/trademarks/index.html for details. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. © Shimadzu Corporation, 2019 www.shimadzu.com/an/ Application News No. M283 Confirmation of Quantitation Accuracy The above-mentioned pretreatment to reference standards of 8 μg each of 22 types of bile acid was carried out, and a GC-MS analysis was conducted in the scan mode. Fig. 4 shows the cholic acid peaks. After confirming the retention time and mass spectra of each bile acid, the same treatment as described above was carried out for 0.1, 0.5, 1.0, 5.0, 10, 50, 100 and 500 ng reference standard mixtures of the 22 bile acids. SIM analysis was carried out, and a calibration curve was prepared by the internal standard method using Cholic acid-d5 as the internal standard. Fig. 5 shows the calibration curve. The dynamic range and linearity of each bile acid were as shown in Table 2. For compounds from which multiple peaks were detected from one standard, the respective peaks are indicated by the numbers in parentheses. Table 2 shows the reproducibility at the minimum concentration in each dynamic range for n=3. Verification of Sample Stability The above-mentioned pretreatment to reference standards of 8 μg each of the 22 bile acids was carried out, and a second analysis was conducted 20 h after the initial analysis. The relative intensity of the peaks at that time (the ratio to the intensity of the peaks of a first analysis) is shown in the column “Relative peak area after 20 h” in Table 2. All of the bile acid peaks showed satisfactory reproducibility of 70% to 120%. When a similar analysis was also carried out after 38 h, the peak areas of several bile acids showed a decreasing tendency, but with the exception of those samples, stable measurement of the majority of bile acids was possible. Fig. 4 Mass Chromatogram of 8 μg Sample of Cholic Acid Fig. 5 Calibration Curve of Cholic Acid Table 2 Measurement Results of 22 Bile Acids Bile acid CAS No. Quantitative analysis m/z Validation m/z Dynamic range (ng) Linearity (R 2 ) Reproducibility of n=3 (%RSD) Relative peak area after 20 h Relative peak area after 38 h Cholic acid 81-25-4 368.0 458.0 0.1 – 100 0.999 6.65 0.984 1.011 Chenodeoxycholic acid 474-25-9 370.0 355.0 0.5 – 100 0.999 4.71 0.949 0.920 Ursodeoxycholic acid 128-13-2 460.0 370.0 0.5 - 500 0.999 2.24 1.206 0.924 Deoxycholic acid 302-95-4 255.0 370.0 0.5 - 100 0.999 6.11 0.980 0.714 Lithocholic acid 434-13-9 372.0 357.0 1 - 500 0.999 7.66 0.991 0.750 Hyocholic acid 547-75-1 458.0 369.0 0.1 - 100 0.999 5.51 1.036 1.035 3-oxocholic acid_(1) 2304-89-4 546.0 341.0 1 - 500 0.999 7.95 0.848 0.575 3-oxocholic acid_(2) 2304-89-4 269.0 384.0 0.5 - 500 0.999 2.36 0.914 0.714 7-oxodeoxycholic acid 911-40-0 341.0 359.0 1 - 500 0.999 5.51 1.029 1.053 7-oxolithocholic acid 4651-67-6 293.2 353.25 5 - 500 0.998 8.89 0.817 0.920 Ursocholic acid 2955-27-3 253.0 343.0 0.5 - 100 0.999 5.52 1.019 0.840 3-oxodeoxycholic acid_(1) 4185-01-7 548.0 343.0 5 - 500 0.999 4.27 0.959 0.645 3-oxodeoxycholic acid_(2) 4185-01-7 548.0 343.0 10 - 500 0.999 12.39 0.930 0.633 3-oxodeoxycholic acid_(3) 4185-01-7 271.0 253.0 5 – 500 0.999 8.20 1.043 0.867 3-oxolithocholic acid_(1) 1553-56-6 460.0 431.0 5 - 500 0.999 5.43 0.959 0.924 3-oxolithocholic acid_(2) 1553-56-6 460.0 431.0 10 - 500 0.997 7.97 0.720 0.481 3-oxolithocholic acid_(3) 1553-56-6 273.0 318.0 5 – 500 0.999 3.08 0.885 0.809 Hyodeoxycholic acid 83-49-8 370.0 255.0 0.5 - 500 0.999 6.44 1.139 0.860 3β-hydroxy-5-cholenoic acid 5255-17-4 331.0 370.0 5 - 500 0.999 3.95 0.993 0.927 α-muricholic acid 2393-58-0 458.0 443.0 5 - 500 0.999 5.09 1.027 0.834 β-muricholic acid 2393-59-1 285.0 458.0 0.5 - 500 0.998 7.21 0.866 1.033 ω-muricholic acid 6830-03-1 285.0 369.0 0.5 - 500 0.999 4.49 0.842 0.882 Phoenodeoxycholic acid 566-17-6 255.0 370.0 0.5 - 500 0.999 5.48 0.977 0.962 Isolithocholic acid 1534-35-6 372.0 215.0 1 - 500 0.999 2.38 1.051 0.920 Alloisolthocholic acid 2276-93-9 372.0 447.0 5 - 500 0.999 4.35 1.080 1.033 12-oxolithocholic acid 5130-29-0 476.0 386.0 5 - 500 0.998 8.51 0.769 0.937 isodeoxycholic acid 570-63-8 255.0 345.0 0.5 - 500 0.999 0.68 0.952 0.623 The product described in this document has not been approved as a medical device under the Pharmaceutical and Medical Device Act of Japan. It cannot be used for the purpose of medical examination and treatment or related procedures. GCMS-QP is a trademark of Shimadzu Corporation in Japan and/or other countries. 15.5 16.0 1.0 2.0 3.0 4.0 5.0 (x1,000,000) 343.20 458.00 368.00 0.0 25.0 50.0 75.0 Conc 0.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 Area Ratio R 2 = 0.9994
Related Products Some products may be updated to newer models. GCMS-QP2020 NX Gas Chromatograph Mass Spectrometer Related Solutions Food Metabolomics Life Science Lipidomics Price Inquiry Product Inquiry Technical Service / Support Inquiry Other Inquiry Powered by TCPDF (www.tcpdf.org)