User Benefits Application News Analysis of Water-Soluble Vitamins in Foods by LCMS-8060NX Triple Quadrupole Mass Spectrometer M. Kawashima LCMS™-8060NX High Performance Liquid Chromatograph Mass Spectrometer Simultaneous quantitative analysis of water-soluble vitamins with largely different contents is possible. Because the IonFocus™ unit introduces ions into the MS with high efficiency, both excellent system robustness and high sensitivity analysis are achieved when moving the ion spray away from the ion inlet port to mitigate contamination. The analysis results show a high recovery rate even in analysis of complex food matrices such as modified milk powder (powdered infant formula) and milk raw material. Introduction Vitamins are classified as water-soluble vitamins or fat-soluble vitamins depending on their nature. Although the general analysis techniques for water-soluble vitamins include microbiological methods (bioassay), fluorescence methods, and the HPLC method, with the exception of HPLC, only one vitamin can be measured by those analysis methods. Thus, the time and labor required with those methods is a drawback. The HPLC method enables simultaneous measurement of multiple vitamins, but depending on the vitamin, the content in foods may be trace amount, and in some cases, this is an obstacle to analysis in complex matrices. With the LC/MS/MS method, simultaneous quantitative analysis of vitamins with higher efficiency is possible because vitamins can be analysed with selectivity and high sensitivity even in complex matrices. However, contamination of the MS is a problem when measuring complex matrices like those of foods. As one solution to this problem, the effects of contaminants can be minimized by separating the ionization unit from the MS ion introduction unit. The IonFocus Unit of the LCMS-8060NX efficiently introduces only ions into the MS and enables high sensitivity analysis while minimizing contamination of the MS unit because the ionization unit is separated from the MS ion introduction unit. In this article, we report the development of an analysis method for four water-soluble vitamins and an example of simultaneous analyses of the vitamins in food products using the LCMS- 8060NX. Fig. 1 Concept of IonFocus Unit Measurement Samples The sample solutions *1 used here were prepared by acid hydrolysis of four modified milk powders and milk raw material. Analysis Conditions Table 1 shows the LSMS analysis conditions, and Table 2 shows the MS/MS parameters. Although the MS/MS parameters for each compound were selected by the automatic MRM optimization function, the collision energies of nicotinamide and pantothenic acid were set to different values from the selected optimum values to adjust the conditions to a suitable calibration curve range for the concentrations of the sample solutions used in the quantitative analysis. In the LCMS-8060NX IonFocus unit used in the mass spectrometer, focus electrodes efficiently introduce only ions into the MS while expelling unnecessary neutral particles. For this analysis, the probe position was set to 4.5 mm, and high sensitivity was realized by the effect of the IonFocus unit while minimizing contamination of the MS when moving the ion spray away from the ion inlet port. Focus electrodes Efficient introduction of only ions Removal of neutral particles (matrix) that cause matrix effect and contamination Table 1 LCMS Analysis Conditions Table 2 MS/MS Parameters [HPLC conditions] (Nexera™ X3) Column : L-column3 C18 Metal-free (150 mmL. u 2.0 mm I.D., 3.0 μm) Mobile phases : A) 10 mmol/L Ammonium bicarbonate in H2O B) Acetonitrile Gradient Program : B 2% (0-3 min) – B 60% (4-5 min) – B 98 % (5.01-9 min) – B 2 % (9.01-13 min) Flow rate : 0.35 mL/min Column Temp. : 40 ˚C Injection volume : 1 μL [MS conditions] (LCMS-8060NX) Ionization : ESI (Positive mode) Probe Voltage : -0.5 kV Mode : MRM Nebulizing gas flow : 3.0 L/min Drying gas flow : 25.0 L/min Heating gas flow : 15.0 L/min DL/ Heat Block Temp. : 250 ˚C/300 ˚C Interface Temp. : 400 ˚C Probe position : 4.5 mm Compound Quantitative MRM transition (m/z) Qualitative MRM transition (m/z) Biotin 245.10>227.00 245.10>96.95 Nicotinic acid 124.00>80.00 124.00>78.05 Nicotinamide 123.00>79.90 123.00>77.90 Pantothenic acid 220.10>89.90 220.10>202.15 Ion inlet port
Application News www.shimadzu.com/an/ Shimadzu Corporation Analytical & Measuring Instruments Division Global Application Development Center © Shimadzu Corporation, 2021 For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. See http://www.shimadzu.com/about/trademarks/index.html for details. Third party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “£”. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. First Edition: Jul. 2021 01-00033-EN LCMS, IonFocus, Nexera are trademark of Shimadzu Corporation in Japan and/or other countries. L-column is a trademark of Chemicals Evaluation and Research Institute, Japan in Japan and/or other countries. Fig. 2 Chromatograms and Calibration Curves Analysis Results of Milk Raw Material Three repeated analyses of each sample solution were carried out, and a quantitative analysis of the water-soluble vitamins was conducted. Fig. 3 shows the chromatograms when the milk raw material samples were analyzed. Table 4 shows the results of a comparison of these quantitative values and the values obtained by the bioassay method. Analysis Results of Standard Samples Linearity was confirmed by three repeatability analyses of the standard samples prepared for the calibration curves. Fig. 2 shows the chromatograms at the lowest concentrations of the calibration points and the calibration curves prepared by the external standard method. Table 3 summarizes the range of the calibration curves. The calibration points were decided based on accuracy of within 80 to 120% for all calibration points and confirmation of peak area repeatability of 20% or less. Satisfactory linearity was obtained, as the correlation coefficient R = 0.998 or higher for all components. Biotin Nicotinic acid Nicotinamide Pantothenic acid 1.34e4 Q 245.10>227.00 (+) Standard 0.102 ng/mL Blank 4.0 4.2 4.4 4.6 1.0e3 2.0e3 3.0e3 4.0e3 3.83e3 Q 124.00>80.00 (+) Standard 0.500 ng/mL Blank 1.2 1.4 1.6 2.0e3 4.0e3 6.0e3 2.68e2 Q 123.00>79.90 (+) Standard 0.605 ng/mL Blank 2.6 2.8 3.0 3.2 0.0e0 2.0e2 4.0e2 4.75e2 Q 220.10>89.90 (+) Standard 1.02 ng/mL Blank 1.4 1.6 1.8 2.0 0.0e0 2.0e2 4.0e2 6.0e2 8.0e2 Concentration (ng/mL) 0 200 400 Peak area 0.0e0 2.0e6 4.0e6 6.0e6 8.0e6 Nicotinic acid y = 18735.08x - 49.62641 R 2 = 0.9999014 R = 0.9999507 Concentration (ng/mL) 0 100 200 Peak area 0.0e0 1.0e7 2.0e7 3.0e7 Biotin y = 131254.0x - 3419.850 R 2 = 0.9996599 R = 0.9998299 Concentration (ng/mL) 0 200 400 Peak area 0.0e0 2.0e5 4.0e5 6.0e5 Nicotinamide y = 1313.210x + 234.5605 R 2 = 0.9975418 R = 0.9987701 Concentration (ng/mL) 0 200 400 Peak area 0.0e0 2.0e5 4.0e5 6.0e5 8.0e5 Pantothenic acid y = 1601.175x + 256.9282 R 2 = 0.9992395 R = 0.9996197 Table 3 Range of Calibration Curves of Water-Soluble Vitamins (ng/mL) Compound Calibration curve (ng/mL) Correlation coefficient (R) Biotin 0.102 - 254 0.999 Nicotinic acid 0.500 - 500 0.999 Nicotinamide 0.605 - 605 0.998 Pantothenic acid 1.02 - 510 0.999 Conclusion A simultaneous analysis method for water-soluble vitamins using LC/MS/MS was developed. Accurate quantitative analysis of water-soluble vitamins in complex matrices, exemplified here by modified milk powder and milk raw material, was possible by using this analysis method. 2.92e4 Q 245.10>227.00 (+) 4.0 4.2 4.4 4.6 0.0e0 2.0e4 4.0e4 4.91e4 Q 124.00>80.00 (+) 1.2 1.4 1.6 0.0e0 2.5e4 5.0e4 7.5e4 1.66e4 Q 123.00>79.90 (+) 2.6 2.8 3.0 3.2 0.0e0 1.0e4 2.0e4 3.0e4 1.26e5 Q 220.10>89.90 (+) 1.4 1.6 1.8 2.0 0.0e0 1.0e5 2.0e5 Biotin Nicotinic acid Nicotinamide Pantothenic acid Fig. 3 Chromatograms of Water-Soluble Vitamins in Milk Raw Material Table 4 Comparison of LC/MS/MS Method and Bioassay Results Compound LC/MS/MS Bioassay Biotin 56.24 60.8 Niacin * 242.45 274.7 Pantothenic acid 1.14 1.33 * The values for niacin are the totals of nicotinic acid and nicotinamide. Results of Spike-and-Recovery Tests of Modified Milk Powder and Milk Raw Material Each of the sample solutions was spiked with water-soluble vitamins, and spike-and-recovery tests were conducted. Table 5 shows the test results. Table 5 Recovery Rates of Sample Solutions Compound Modified milk powder 01 Modified milk powder 02 Modified milk powder 03 Modified milk powder 04 Milk raw material Biotin 79.4% 86.0% 52.9% 84.4% 76.1% Nicotinic acid 90.6% 112.0% 91.2% 89.7% 102.8% Nicotinamide 89.1% 98.0% 115.6% 92.4% 88.8% Pantothenic acid 80.8% 103.6% 103.2% 87.5% 98.7% *1 We wish to express our deep appreciation to MORINAGA MILK INDUSTRY CO., LTD. for providing the sample solutions used in this paper.
Please fill out the survey Related Products Some products may be updated to newer models. LCMS-8060NX Liquid Chromatograph Mass Spectrometer LCMS-TQ RX Series Triple Quadrupole LC- MS/MS Triple Quadrupole LC-MS/MS Nexera series Ultra High Performance Liquid Chromatograph Related Solutions Food and Nutrition Price Inquiry Product Inquiry Technical Service / Support Inquiry Other Inquiry Powered by TCPDF (www.tcpdf.org)