Content overflows the browser. Try zooming out (Ctrl + −) to see the full page. PDF Download
User Benefits Application News Development of Vitamin E Analysis in Palm Oil Significant reduction of analytical time compared with normal phase HPLC analysis. Reduction of organic solvent consumption compared with normal phase HPLC analysis. Supercritical Fluid Chromatograph - Nexera TM UC Introduction Palm oil is made from oil palm and mainly produced in Asia. Palm oil contains various functional natural compounds, which include tocopherol homologues known as Vitamin E. Currently, normal phase HPLC is widely used for quantitative analysis of tocopherol homologues in palm oil. However, this separation mode requires a long time more than 15 min and consumes much organic solvent. Here, we introduce the analysis method for tocopherol in palm oil using Nexera UC, which is Shimadzu supercritical fluid chromatograph (SFC), and compare the analytical time and organic solvents consumptions against conventional HPLC analysis. Analytical method of tocopherol homologues by normal phase HPLC Fig. 1 shows the chemical structure of tocopherol homologues. Tocopherol has main four types of homologues, and they are required to measure for quality control in palm oil manufacturing. Tocopherol homologues in palm oil are typically analyzed in normal phase HPLC that uses much n-hexane. Table 1 and Fig.2 show analytical conditions and chromatogram of tocopherol homologues by normal phase HPLC analysis. Column : Shim-pack TM CLC-SIL *1 (250 mm× 4.6 mm I.D., 5 μm) Mobile phase : n-hexane/2-propanol=100:0.5 Flow rate : 2 mL/mn Column temp. : 40 ̊ C Injection Vol. : 20 μL Vial : SHIMADZU LabTotal™ for LC 1.5 mL, Glass *2 Detection : PDA 292 nm Table 1 Analytical Conditions(HPLC) 1* P/N: 228-17872-92 2* P/N: 227-34001-01 About Supercritical fluid chromatography Supercritical Fluid Chromatography (SFC) is one of the chromatography systems with supercritical fluid (i.e., supercritical carbon dioxide) as mobile phase. The low cost of carbon dioxide (purity: 99.9 %) can significantly trim the total running cost of analyses. Generally, SFC shows high separation than typical HPLC and shortens analytical time. Furthermore, SFC can replace normal phase HPLC because supercritical carbon dioxide is similar to n-hexane. Method development of analytical conditions of tocopherol homologues by SFC Table 2 shows the analytical conditions for SFC, and fig 3 shows the acquired chromatogram. We created the calibration curves for alpha-tocopherol in the range from 0.8 mg/L to 500 mg/L. The calibration curves for other tocopherol homologues were created in the range from 0.8 mg/L to 100 mg/L. Repeatability, linearity of the calibration curves, and LOD (limit of detection) are summarized in Table 3. Column : Shim-pack UC-X NH2 *3 (250 mm× 2.1 mm I.D., 5 μm) Mobile phase : A: CO2 B: Methanol Flow rate : 4 mL/mn Time program : B conc. 1.5 %(0-2.5 min)→ 20 % (2.51-2.9 min) →1.5 %(2.91-3.0 min) Column temp. : 40 ̊ C Injection Vol. : 5 μL Vial : SHIMADZU LabTotal™ for LC 1.5 mL, Glass *2 BPR setting : 15 MPa, 50 ̊ C Detection : PDA 292 nm (reference 500 nm) Table 2 Analytical Conditions(SFC) *3 P/N: 227-30522-02 alpha beta gamma delta R1 CH3 CH3 H H R2 CH3 H CH3 H R3 CH3 CH3 CH3 CH3 Fig. 1 Chemical structures of tocopherol homologues Tocopherol alpha beta gamma delta %RSD (peak area, n=6 (100 mg/L)) 0.24 0.37 0.21 0.65 Linearity of calibration curve 0.9999 0.9999 0.9999 0.9999 LOD (mg/L, calculated values) 0.4 0.6 0.6 0.7 0.0 0.5 1.0 1.5 2.0 2.5 min 0 5 10 15 mV alpha-tocopherol beta-tocopherol gamma-tocopherol delta-tocopherol Fig. 2 Chromatogram of tocopherols by normal phase HPLC 0.0 2.5 5.0 7.5 10.0 12.5 min 0 10 20 30 40 mV alpha-tocopherol beta-tocopherol gamma-tocopherol delta-tocopherol Fig. 3 Chromatogram of tocopherol homologues by SFC Table 3. Repeatability, linearity, and LOD of tocopherol homologues Kosuke Nakajima 1,2 Mei hui 3 1 Shimadzu Corporation, 2 Shimadzu (Asia Pacific) Pte Ltd., 3 Shimadzu Malaysia Sdn. Bhd.
Application News Copyright © 2021 SHIMADZU group. All rights reserved. these products in your country. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. See http://www.shimadzu.com/about/trademarks/index.html for details. Third party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “”. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. 04-AD-0247-EN First Edition: Sep. 2021 For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of Conclusion A novel SFC method was developed for quantitative analysis of tocopherol homologues in palm oil using Nexera UC system. SFC significantly reduces the running time of analysis time and organic solvent consumption than typical HPLC. Moreover, SFC is possible to connect a mass spectrometer or FRC-40 SF as a fraction collector. Nexera UC system is expected to be used widely from R&D to quality control in the food industry. Shimadzu Corporation www.shimadzu.com/an/ SHIMADZU (Asia Pacific) Pte. Ltd, www.shimadzu.com.sg Comparison of analysis time and mobile phase consumptions Fig. 6 shows the comparison chromatogram between normal phase HPLC analysis and SFC analysis. The normal phase analysis required 15 min. However, the SFC method was completed in about 3 minutes. Shorten five times or less analytical time than the typical normal phase HPLC method. A comparison of mobile phase consumption is shown in Table 5. The SFC method significantly reduced the organic solvent consumption compared to normal phase HPLC. In addition, SFC method reduced the total running cost owing to the low cost of carbon dioxide used for SFC. Tocopherol (mg/L) alpha beta gamma delta Palm oil 1 358.6 7.1 10.4 1.1 Palm oil 2 17.0 0.6* 0.6* N.D. Palm oil 3 20.1 0.7* 1.0 1.0 Palm oil 4 11.1 1.0 0.6* N.D Table 4 Quantitative results of tocopherol homologues in Palm oils * Should be considered reference values, as they were obtained by extrapolation from the calibration curve. Analysis of tocopherol homologues in palm oil We analyzed the concentration of tocopherol homologues for several types of palm oils. Fig. 4 shows the information of palm oils and the pretreatment method for them. Fig 5 shows acquired chromatograms of palm oils by SFC, and table 4 shows the quantitative results for the concentration of tocopherol homologues in each palm oil. These results show that all palm oils contains high concentrate alpha- tocopherol, and the crude palm oil contained the most significant amount of tocopherol homologues than other palm oils. Palm oil 1 Crude palm oil Palm oil 2 Extracted palm oil Palm oil 3 Extracted palm oil Palm oil 4 Palm kernel oil Palm oils 1 mL Add n-hexane 9 mL Mix using a vortexer 3 min , ambient Centrifuged 5000 g, 5 min Supernatant 5 mL SFC (5 μL) Filtration PTFE, 0.22 μm Palm oil 1 Palm oil 2 Palm oil 3 Palm oil 4 Table 5 Comparison of organic solvents consumption 0.0 0.5 1.0 1.5 2.0 2.5 0 10 20 30 40 50 60 70 80 mAU 90 alpha-tocopherol beta-tocopherol gamma-tocopherol delta-tocopherol tocopherol STD Palm oil 1 Fig. 5 Chromatogram of tocopherol homologues by SFC Fig. 4 Palm oils information and pretreatment method Mobile Phase Usage Volume Organic solvent consumptions Preparative HPLC n-hexane 29.8 mL 30 mL 2-propanol 0.2 mL SFC CO2 6.6 mL 0.5 mL Methanol 0.5 mL 0.0 2.5 5.0 7.5 10.0 12.5 min 0 10 20 30 40 mV 0 5 10 15 mV 0.0 2.5 Fig. 6 Comparison of chromatograms and analytical time (upper HPLC, lower SFC) Analytical time is decreased by 4/5 HPLC SFC Nexera, SHIMADZU LabTotal, and Shim-pack are trademarks of Shimadzu Corporation or its affiliated companies in Japan and/or other countries.
Please fill out the survey Related Products Some products may be updated to newer models. Nexera UC Supercritical Fluid Extraction / Supercritical Flu… Related Solutions Food and Nutrition Price Inquiry Product Inquiry Technical Service / Support Inquiry Other Inquiry Powered by TCPDF (www.tcpdf.org)