User Benefits Application News Constituent Sugar Analysis of Cellulose Nanofibers This method enables simultaneous analysis of the main constituent sugars of cellulose nanofiber (CNF). High sensitivity and selectivity analysis of saccharides is possible by using the post-column fluorescence derivatization method. Y. Zhou, A. Uchida High Performance Liquid Chromatograph Nexera™ Reducing Sugar Analysis System Introduction Cellulose nanofiber (hereinafter, CNF) is a technology which effectively utilizes biomass with high efficiency, and thus is one approach toward building a sustainable recycling society system. Plant cell walls consist of fibers called cellulose microfibrils, in which cellulose molecule chains are bound together in a regular structure. The substance obtained by physically or chemically defibrillating cellulose microfibrils is called CNF. In recent years, bacterial cellulose nanofibers (BCNF) has also been produced by using bacteria to synthesize cellulose from biomass-derived glucose. Because the saccharides that make up the complete CNF differ depending on the type of biomass used as the material of the CNF, it is necessary to determine the type and ratio of the saccharides when commercializing a CNF product. Here, various types of CNF were hydrolyzed, and the types and ratios of their constituent sugars were determined with a Nexera reducing sugar analysis system. Fig. 1 Flow Path Diagram of Nexera Reducing Sugar Analysis System Sample Preparation Table 1 shows a list of samples used in the analyses, and Fig. 2 shows the sample preparation protocol. Table 1 List of Samples Nexera Reducing Sugar Analysis System Fig. 1 shows the flow path diagram of the Nexera reducing sugar analysis system. In this system, saccharides are separated with a column, then detected by a fluorescence detector due to post-column derivatization. The fluorescence detection method takes advantage of the fact that saccharides form strongly fluorescent derivatives when thermally reacted with arginine in the presence of boric acid. The derivatized saccharides can be detected with high sensitivity using a fluorescence detector (RF- 20AXS). This system enables the analysis of saccharides at low concentrations, which was difficult with differential refractive index detectors. No. Sample 1 CNF derived from broadleaf tree pulp-1 2 CNF derived from broadleaf tree pulp-2 3 CNF derived from broadleaf tree pulp-3 4 Carboxymethyl cellulose 5 CNF derived from coniferous tree pulp 6 Fermented nanocellulose (Hydrophilic type) 7 Fermented nanocellulose (Amphipathic type) 8 Commercially available cotton 1. Freeze drying 2. Primary hydrolysis 3. Secondary hydrolysis 4. Neutralization 5. Filtration and dilution Transfer about 0.03 g of the sample to 25 mL of the test tube. 300 µL of 72 % sulfuric acid is added to the test tube. Immerse the test tube in a 30 ˚C water bath for about 1 hour. Mix with a vortex mixer or glass rod every 15 minutes to completely dissolve the sample. Add 8.4 mL of ultrapure water to the test tube, and mix well. The test tube is heated in an autoclave for 60 minutes at 120 ˚C. Filter through glass fiber filter paper, and dilute with 10 mL of ultrapure water. While checking the pH with a pH test paper, a saturated aqueous solution of barium hydroxide *1 is added, neutralized *2 , and sulfuric acid is salted out. Filter through a membrane filter with a pore size of 0.2 µm. Dilute with ultrapure water *3 . All samples are lyophilized. *1 Dissolve 8 g of barium hydroxide octahydrate in 100 mL of ultrapure water. *2,*3 The ratio and magnification vary depending on the sample. See Table 2. Fig. 2 Sample Preparation Protocol
Application News Because the neutralization conditions and concentrations of saccharides differ depending on the type of sample, the ratio of the saturated barium hydroxide solution and the sample dilution ratio with water were changed for each sample. Table 2 shows the conditions used with each sample. Linearity of Calibration Curves Fig. 4 shows the calibration curves prepared based on the results of the analysis of the standard solution. Table 4 shows the ranges of the calibration curves. Good linearities were confirmed for all saccharides, as the contribution ratio r 2 = 0.999 or greater. Table 2 Neutralization Conditions and Dilution Ratios Used in Sample Preparation Sample Sample : Saturated barium hydroxide solution (v:v) pH Dilution ratio 1 150 : 450 4 8 2 600 : 300 3 8 3 600 : 300 7 8 4 600 : 300 3 4 5 500 : 250 4 8 6 600 : 300 4 4 7 600 : 300 3 4 8 600 : 400 3 8 Analytical Conditions Table 3 shows the analytical conditions used for the hydrolyzed samples. Because saccharides have the property of forming anionic complexes with boric acid, the saccharides were separated with a Shim-pack™ ISA-09 anion exchange column using borate buffer solutions as the mobile phase. Fig. 3 shows the chromatogram of the standard solution. Table 3 Analytical Conditions 0 25 50 75 min 0.0 2.5 5.0 7.5 10.0 mV 1 2 3 4 5 6 1. Cellobiose 2. Mannose 3. Arabinose 4. Galactose 5. Xylose 6. Glucose System : Nexera Reducing Sugar Analysis System <Separation> Column : Shim-pack ISA-09 (250 mm × 4.0 mm I.D.) *4 Guard column : Shim-pack ISA-09 (G) (50 mm × 4.0 mm I.D.) *5 Mobile phase A : 0.1 mmol/L Potassium borate buffer solution (pH 8) Mobile phase B : 0.4 mmol/L Potassium borate buffer solution (pH 9) Flow rate : 0.6 mL/min Time program : B Conc. 0 % (0 min) - 100 % (50 min) - 100 % (65 min) - 0 % (65.01-90 min) Gradient mixer capacity : 1.7 mL Column temp. : 65 ˚C Injection vol. : 10 µL Vial : SHIMADZU LabTotal ™ for LC 1.5 mL, Glass *6 <Post-column reaction> Reaction reagent : 10 g/L Arginine and 30 g/L boric acid aqueous solution Flow rate : 0.5 mL/min Reaction temp. : 150 ˚C Detection : Ex. 320 nm, Em. 430 nm (RF-20AXS) Cell temp. : 25 ˚C Reaction coil : SUS tubing, 10 m × 0.8 mm I.D. *4 P/N: 228-59512-41, *5 P/N: S228-59512-42, *6 P/N: 227-34001-01 Fig. 3 Chromatogram of Standard Solution (500 μmol/L each) Conc.(µmol/L) Area (x10 5 ) Cellobiose r 2 =0.9995 0 100 200 300 400 0 1 2 3 4 5 Area (x10 5 ) 500 Area (x10 5 ) Mannose r 2 =0.9991 0 100 200 300 400 0 1 2 3 500 Conc.(µmol/L) Area (x10 5 ) Conc.(µmol/L) Arabinose r 2 =0.9998 0 100 200 300 400 0 1 2 3 4 5 6 500 Conc.(µmol/L) Galactose r 2 =0.9997 0 100 200 300 400 0 1 2 3 4 5 500 Area (x10 5 ) Conc.(µmol/L) Xylose r 2 =0.9995 0 100 200 300 400 0 5 500 1000 Conc.(µmol/L) Glucose r 2 =0.9998 Area (x10 5 ) 0 250 500 750 0 5 Fig. 4 Calibration Curves of Compounds Table 4 Calibration Curve Ranges of Compounds Compound Calibration curve range (µmol/L) Cellobiose 5-500 Mannose 5-500 Arabinose 5-500 Galactose 5-500 Xylose 5-500 Glucose 50-1000 Repeatability of Standard Solution Table 5 shows the relative standard deviation (%RSD) of the retention time and peak area for 6 repeated analyses of a standard solution containing 500 μmol/L of each compound. Good repeatability was obtained for all compounds, showing that the system performance is stable. Table 5 Repeatability of Retention Time and Peak Area of Compounds (n = 6) Compound Retention time (%RSD) Peak area (%RSD) Cellobiose 0.04 0.10 Mannose 0.02 0.17 Arabinose 0.01 0.13 Galactose 0.01 0.17 Xylose 0.01 0.12 Glucose 0.01 0.13 Constituent Sugars Analysis of CNF Samples The samples listed in Table 1 were prepared in accordance with the protocol shown in Fig. 2, and were then analyzed with the Nexera reducing sugar analysis system. Fig. 5 shows the chromatographs for each CNF sample. Saccharides can be detected with high sensitivity and selectivity by using the post- column derivatization reaction method.
Application News 0.0 25.0 50.0 75.0 min 0 1 2 3 4 5 6 7 mV 2 3 4 5 6 Sample No.1 0.0 25.0 50.0 75.0 min 0 1 2 3 4 mV 5 6 Sample No.2 0.0 25.0 50.0 75.0 min 0 1 2 3 4 5 mV 5 6 Sample No.3 0.0 25.0 50.0 75.0 min 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 mV 5 6 1. Cellobiose 2. Mannose 3. Arabinose 4. Galactose 5. Xylose 6. Glucose Sample No.4 0.0 25.0 50.0 75.0 min 0 1 2 3 4 5 mV Sample No.5 2 5 6 0.0 25.0 50.0 75.0 min 0 1 2 3 4 5 6 7 mV 6 Sample No.8 0.0 25.0 50.0 75.0 min 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 mV 6 Sample No.7 40 50 60 0 1 mV 2 3 4 5 6 40 50 60 0 1 mV 2 3 5 6 3 min min 40 50 60 70 0.00 0.25 mV 3 6 0.0 25.0 50.0 75.0 min 0.0 2.5 5.0 7.5 mV 6 Sample No.6 40 50 60 70 0.00 0.25 mV 3 6 3 3 Fig. 5 Chromatograms of CNF Samples
Application News www.shimadzu.com/an/ Shimadzu Corporation Analytical & Measuring Instruments Division Global Application Development Center © Shimadzu Corporation, 2022 For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. See http://www.shimadzu.com/about/trademarks/index.html for details. Third party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “”. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. First Edition: Mar. 2022 01-00023-EN Fig. 6 Ratios of Constituent Sugars of CNF Samples Table 6 Recovery Rates and Excessive Decomposition Correction Factors for Monosaccharides *7 In this analysis, the samples were hydrolyzed in sample preparation, and a quantitative analysis of the monosaccharides was performed. Scale factor is the coefficient that takes into account dehydration condensation. Ratio of Constituent Sugars Spike-and-recovery test, correction for excessive decomposition, and calculation of polysaccharide were carried out using the quantitative values of the detected saccharides. Fig. 6 shows the composition ratio of each saccharide when the integrated value is defined as 100. Summary It was possible to determine the ratios of the constituent sugars in various CNF samples by analyzing the saccharides in the samples after hydrolysis treatment using the Nexera reducing sugar analysis system. Differences in the types and amounts of constituent sugars could be seen in the CNFs derived from different materials. As shown in Fig. 7, cellulose is a polysaccharide which is polymerized by glycosidic linkage of glucose, whereas the main components of hemicellulose are the insoluble dietary fibers xylan, which is formed by polymerization of xylose or other saccharides, and mannan, which is formed by polymerization of glucose and mannose. It is known that hemicellulose is distributed in large amounts in broadleaf trees. Analysis of Binfi-s (Sugino Machine Limited, Toyama, Japan) produced from wood pulp showed that, a large amount of xylose tends to be detected in addition to glucose. However, BCNFs such as fermented nanocellulose, which are formed by bacteria from the glucose in molasses or agricultural raw materials, consisted of 90 % or more glucose, and did not contain xylose, which has been confirmed to originate from wood pulp. Spike-and-Recovery Test, Correction for Excessive Decomposition, and Calculation of Polysaccharide Because the saccharides in the samples may decompose due to excessive decomposition during hydrolysis, it is necessary to correct by performing a spike-and-recovery tests of the monosaccharides. For this test, 8.4 mL of a mixed standard solution of the monosaccharides (each saccharide: 500 μmol/L) was taken in a 25 mL test tube, and 300 μL of 72 % sulfuric acid was added with a pipette. Two test solutions were prepared. One (solution a) was decomposed by heating in an autoclave for 1 hour at 120 ˚C simultaneously with hydrolysis. After cooling, water was added to the autoclaved solution until the total volume reaches 10 mL. The other (solution b) was simply adjusted to 10 mL with water without being heated in the autoclave. Both solutions were diluted 4 times, after which quantitative analyses of solutions a and b were performed, and the recovery rate of each monosaccharide before/after hydrolysis was obtained. Correction for excessive decomposition was carried out by multiplying the monosaccharide concentration of the sample before correction by the reciprocal of the recovery rate. Table 6 shows the recovery rates and the excessive decomposition correction factors for each monosaccharide. The calculation of polysaccharide was carried out by multiplying the corrected monosaccharide concentration by the scale factor of monosaccharide that is 0.9 for a hexose and 0.88 for a pentose. *7 Compound Recovery rate (%) Correction factor for the excessive decomposition Xylose 87 1.15 Arabinose 92 1.08 Mannose 94 1.07 Glucose 95 1.06 Galactose 92 1.08 0% 20% 40% 60% 80% 100% No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 Xylose Arabinose Mannose Glucose Galactose Cellobiose Glucose Xylose Mannose Arabinose Cell wall of plants Cellulose Hemicellulose Hydrolysis Hydrolysis Fig. 7 Cellulose and Hemicellulose <Acknowledgments> We wish to express our profound thanks to the following persons for useful discussion and various advice in connection with the development of this analysis method and provision of the samples. • The University of Tokyo: Special Research Professor Akira Isogai, Associate Professor Tsuguyuki Saito, and Assistant Professor Shuji Fujisawa • Hokkaido University: Associate Professor Kenji Tajima • Kusano Sakko Inc.: Mr. Tokuo Matsushima, General Manager of Nanocellulose/Agricultural Business • Ehime University: Professor Hiromi Uchimura, Professor Tomoki Yabutani, and Assistant Professor Akihiro Hideno Nexera, Shim-pack and SHIMADZU LabTotal are trademarks of Shimadzu Corporation or its affiliated companies in Japan and/or other countries.
Related Products Some products may be updated to newer models. Nexera series Ultra High Performance Liquid Chromatograph Shim-pack IC Series HPLC Column Related Solutions Advanced Materials Price Inquiry Product Inquiry Technical Service / Support Inquiry Other Inquiry Powered by TCPDF (www.tcpdf.org)