Content overflows the browser. Try zooming out (Ctrl + −) to see the full page. PDF Download
User Benefits Application News Quantitation of NDMA and NDEA in Metformin and 5 Sartan APIs as per the EDQM method Procedure B This application note demonstrates applicability of EDQM method (Procedure B) for Metformin in addition to Sartan APIs. The GCMS-QP2020 NX with AOC-30i system achieves LOQ lower than the EDQM method (Procedure B) meeting the defined criteria of S/N and recovery. Introduction Overview : The Drug Regulatory Authorities first noticed the presence of the N-Nitrosamine impurity (NSA), N- Nitrosodimethylamine (NDMA) in products containing valsartan in July 2018. Valsartan is an Angiotensin II Receptor Blocker (ARB) and belongs to a family of analogue compounds commonly referred to as the Sartans. Similarly, NSA has also been detected in other drug products such as Metformin. Metformin is a prescription drug used to control high blood sugar in patients with Type 2 diabetes. Considering the significance of these drugs, it is crucial to make Sartans and Metformin available with safe levels of NSA. Like USFDA, European Directorate for the Quality of Medicines and Healthcare (EDQM) ensure access to good quality medicines in Europe. EDQM has been working actively at various levels to address the presence of Nitrosamines in active substances and medicines. EDQM has been regularly informing all stakeholders, from national authorities to manufacturers, on the state of the works and on initiatives taken. EDQM procedure for NSA: EDQM enlists 3 procedures for determination of NSA viz procedure A, B and C for LC-MS/MS, GC-MS and GC-MS/MS, respectively. Procedures A and B have been validated as limit tests (30 ppb) with recovery demonstrated at limit level. The procedure C has been validated as a quantitative test wherein a three-point calibration is plotted with recovery performed at limit level (30 ppb). This application news describes analytical procedures for the detection of 2 commonly found N-Nitrosamines namely N-Nitrosodimethylamine (NDMA) and N-Nitrosodiethylamine (NDEA) in Sartan and Metformin APIs by procedure B. The procedure B further describes 2 sample preparations procedures namely sample preparation 1 and 2. The sample preparation 1 is used for Valsartan, Losartan and Olmesartan additionally Metformin API is also analysed with this method. The sample preparation 2 is used for Candesartan and Irbesartan. When a procedure is applied to substances outside of the scope covered by the initial validation or to medicinal products or if procedure A or B is used quantitatively, then it must be validated. Experimental A mixture of NDMA, NEMA and NDEA standards was analyzed using scan mode for identification. By referring to the parameters mentioned in procedure B, a GC-MS quantitation method was created (Table 1). EDQM method B uses a two single point calibration methods each for sample preparation -1 and 2. However, in this application news two different calibrations (three-point) each for sample preparation 1 and 2 were plotted. Gas Chromatograph Mass Spectrometer GCMS-QP TM 2020 NX, AOC-30i Nitish Suryawanshi, Dheeraj Handique, Prashant Hase, Sanket Chiplunkar, Durvesh Sawant, Aseem Wagle, Rahul Dwivedi, Jitendra Kelkar and Pratap Rasam Shimadzu Analytical (India) Pvt. Ltd. User Benefits Figure 1: GCMS-QP2020 NX system with AOC-30i autosampler Method Table 1: Instrument configuration and analytical conditions The calibration for sample preparation 1 is ranging from 3.75 ppb to 7.5 ppb whereas, for sample preparation 2 is ranging from 1.5 ppb to 6.0 ppb. Quantitation of NDMA and NDEA was performed using Shimadzu GCMS-QP2020 NX system with AOC-30i autosampler (Figure 1). Note = All above concentrations are as such. GCMS System : GCMS-QP2020 NX with AOC-30i Column : SH-I-624Sil MS 30 m, 0.25 mm I.D., 1.4 µm df (P/N: 221-75962-30) Injection Mode : Splitless (Sampling time 0.5 min) Flow Control Mode : Column Flow Injector Port Temp. : 250 ºC Carrier Gas : Helium Column Flow : 1.0 mL/min Injection Volume : 2.0 µL* Temp. Program Ionization Mode : Electron Ionization (EI) Interface Temp. : 240 ºC Ion Source Temp. : 230 ºC Acquisition Mode : SIM Ions : 74, 88 and 102 amu Ramp Rate (ºC/min) Temp. (ºC) Hold Time (min) - 40 0.5 58.8 140 2 20 180 0.5 30 240 1.8 40 280 2.5 *: EDQM mentions injection volume of 2.5µL
Application News Sample Preparation-1 (Valsartan, Losartan and Olmesartan) Internal standard solution: Dissolve 5.0 mg of N-nitroso- ethylmethylamine (NEMA) in methanol and dilute to 10.0 mL with the same solvent. Dilute 500 μL of the solution to 10.0 mL with water for chromatography. Extraction solution: Dissolve 40.0 g of sodium hydroxide in 800 mL of water for chromatography. Add 100 μL of the internal standard solution and dilute to 1000 mL with water for chromatography. N-Nitrosamines spiking solution: For each N-nitrosamine concerned, use the corresponding Certified Reference Standard (CRS). In a single volumetric flask, dilute 200 μL of each of these CRS to 20.0 mL with water for chromatography. Dilute 300 μL of this solution to 20.0 mL with water for chromatography. Linearity solution-1 (15.0 ppb): Add 50 μL of the N- nitrosamines spiking solution to 10.0 mL of the extraction mixture. Vortex for 5 min. Add 2.0 mL of dichloromethane (DCM) and shake well for at least 5 min, then centrifuge at about 5000 rpm for 5 min. Use the lower organic layer for GCMS injection. Linearity solution-2 (30.0 ppb): Add 100 μL of the N- nitrosamines spiking solution to 10.0 mL of the extraction mixture. Vortex for 5 min. Add 2.0 mL of DCM and shake well for at least 5 min, then centrifuge at about 5000 rpm for 5 min. Use the lower organic layer for GCMS injection. Linearity solution-3 (60.0 ppb): Add 200 μL of the N- nitrosamines spiking solution to 10.0 mL of the extraction mixture. Vortex for 5 min. Add 2.0 mL of DCM and shake well for at least 5 min, then centrifuge at about 5000 rpm for 5 min. Use the lower organic layer for GCMS injection. Test solution: Suspend 250.0 mg of the API to be examined in 10.0 mL of the extraction mixture. Vortex for 5 min. Add 2.0 mL of DCM and shake well for at least 5 min, then centrifuge at about 5000 rpm for 5 min. Use the lower organic layer for GCMS injection. Spiked solution: Suspend 250.0 mg of API in 10.0 mL of the extraction mixture. Add 50 μL of the N-nitrosamines spiking solution to prepare spiked solution with concentrations of 15 ppb. Vortex for 5 min. Add 2.0 mL of DCM and shake well for at least 5 min, then centrifuge at about 5000 rpm for 5 min. Use the lower organic layer for GCMS injection. Sample Preparation-2 (Candesartan and Irbesartan) Internal standard solution: Dissolve 5.0 mg of N-nitroso- ethylmethylamine (NEMA) in methanol and dilute to 10.0 mL with the same solvent. Dilute 100 μL of the solution to 10.0 mL with methanol. Extraction solution: Dilute 100 μL of internal standard solution in 100 mL of dichloromethane. N-Nitrosamines spiking solution: For each N-nitrosamine concerned, use the corresponding Certified Reference Standard (CRS). In a single volumetric flask, dilute 200 μL of each of these CRS to 10.0 mL with methanol. Further, dilute 300 μL of this solution to 20.0 mL with methanol. Linearity solution-1 (15.0 ppb): Add 50 μL of the N- nitrosamines spiking solution to 5.0 mL of the extraction mixture. Shake well for 5 min, then centrifuge at about 5000 rpm for 5 min. Collect the supernatant solution. Note: Below concentrations are with respect to sample concentration. If necessary, filter the supernatant through a membrane filter (0.45 μm) to obtain a clear solution. Use the clear solution for GCMS injection. Linearity solution-2 (30.0 ppb): Add 100 μL of the N- nitrosamines spiking solution to 5.0 mL of the extraction mixture. Shake well for 5 min, then centrifuge at about 5000 rpm for 5 min. Collect the supernatant solution. If necessary, filter the supernatant through a membrane filter (0.45 μm) to obtain a clear solution. Use the clear solution for GCMS injection. Linearity solution-3 (60.0 ppb): Add 200 μL of the N- nitrosamines spiking solution to 5.0 mL of the extraction mixture. Shake well for 5 min, then centrifuge at about 5000 rpm for 5 min. Collect the supernatant solution. If necessary, filter the supernatant through a membrane filter (0.45 μm) to obtain a clear solution. Use the clear solution for GCMS injection. Test solution: Suspend 500.0 mg of the API in 5.0 mL of the extraction mixture. Add 100 μL of methanol. Shake well for at least 5 min, then centrifuge at about 5000 rpm for 5 min. Collect the supernatant solution. If necessary, filter the supernatant through a membrane filter (0.45 μm) to obtain a clear solution. Use the clear solution for GCMS injection. Spiked solution: Suspend 500.0 mg of the API in 5.0 mL of the extraction mixture. Add 100 μL of N-nitrosamines spiking solution. Shake well for at least 5 min, then centrifuge at about 5000 rpm for 5 min. Collect the supernatant solution. If necessary, filter the supernatant through a membrane filter (0.45 μm) to obtain a clear solution. Use the clear solution for GCMS injection. Results and Discussion N-Nitrosamines Expected RRT Found RRT NDMA 0.9 0.9 NEMA (ISTD) 1.0 1.0 NDEA 1.1 1.1 Table 2: RRTs of N-nitrosamines Relative retention time (RRT): Both NDMA and NDEA matched the expected RRT criteria (Table 2). Repeatability : Ratio between area of the peak due to the concerned N-Nitrosamine and the area of the peak due to the internal standard of the reference solution should be less than 20%. The repeatability test passed the criteria (Table 4). Table 3: S/N ratio for linearity solution-1 (15.0 ppb) Signal-to-noise (S/N) ratio: S/N for the peak due to each N- nitrosamine for the spiked solution, should be minimum of 10. (Table 3) APIs S/N for spiked solution NDMA NDEA Candesartan 19 56 Irbesartan 17 29 Losartan 24 28 Olmesartan 66 16 Valsartan 26 16 Metformin 23 75 System suitability : For each N-Nitrosamine
Application News Copyright © 2023 Shimadzu Corporation and/or its affiliates. All rights reserved. For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. See http://www.shimadzu.com/about/trademarks/index.html for details. Third party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “”. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. First Edition: Feb. 2023 Shimadzu Corporation www.shimadzu.com/an/ Shimadzu Analytical (India) Pvt.Ltd. www.shimadzu.in GCMS-TQ is a trademark of Shimadzu Corporation in Japan and/or other countries. 06-SAIP-GC-030-EN N-Nitrosodiethylamine (NDEA) N-Nitrosodimethylamine (NDMA) Figure 2 and 3 depicts the calibration curve and chromatogram of 15.0 ppb standard for NDMA and NDEA. Table 6: Results for recovery study at 15.0 ppb Recovery Study: There is no set criteria for spiked recovery study. The calculated recovery in all spiked solutions is between 70-130 %. (Table 6) Conclusion Quantitation of 2 NSAs in Metformin and 5 Sartan APIs as per EDQM procedure B was successfully demonstrated on Shimadzu GCMS-Q2020 NX with AOC-30i autosampler system. EDQM procedure B is only applicable to Sartans however, this application news demonstrates method applicability to Metformin API as well. The repeatability (n=6) for EDQM LOQ i.e., 30.0 ppb and Shimadzu LOQ i.e., 15.0 ppb was found to be less than 20 %. The S/N ratios for both NDMA and NDEA were easily achieved as per EDQM method procedure B. Accuracy in terms of recovery fulfills acceptance criteria for LOQ concentration i.e.,15.0 ppb. Compound LOQ Comparison Shimadzu EDQM NDMA 15.0 ppb 30.0 ppb NDEA Table 7: LOQ comparison of Shimadzu and EDQM Figure 3: a) Calibration curve as per preparation-1, b) Chromatogram of 15.0 ppb standard as per preparation-1, c) Calibration curve as per preparation-2 d) Chromatogram of 15.0 ppb standard as per preparation-2 Figure 2: a) Calibration curve as per preparation-1, b) Chromatogram of 15.0 ppb standard as per preparation-1, c) Calibration curve as per preparation-2 d) Chromatogram of 15.0 ppb standard as per preparation-2 0.0 0.5 1.0 Conc. Ratio 0.0 2.5 5.0 Area Ratio(x0.1) 1 2 3 a 0.0 0.5 1.0 Conc. Ratio 0.0 2.5 5.0 7.5 Area Ratio(x0.1) 1 2 3 a r 2 = 0.999 r 2 = 0.999 5.0 5.5 6.0 0.50 0.75 1.00 1.25 (x1,000) 74.0000 b 7.00 7.25 0.25 0.50 0.75 1.00 (x1,000) 102.0000 b 5.5 6.0 0.5 0.6 0.7 0.8 0.9 1.0 (x1,000) 74.0000 d 7.00 7.25 7.50 2.0 3.0 4.0 5.0 (x100) 102.0000 d 0.0 0.5 Conc. Ratio 0.0 2.5 5.0 Area Ratio(x0.1) 1 2 3 c r 2 = 0.999 0.0 0.5 Conc. Ratio 0.0 2.5 5.0 7.5 Area Ratio(x0.1) 1 2 3 c r 2 = 0.999 Table 7 depicts the LOQ comparison for Shimadzu application news and EDQM. APIs % Recoveries at 15.0 ppb NDMA NDEA Candesartan 103 122 Irbesartan 115 96 Losartan 95 99 Olmesartan 111 119 Valsartan 107 112 Metformin 98 100 Table 4: Repeatability of area ratio for the reference solutions (n=6) Linearity solutions % Repeatability NDMA NDEA Linearity solution-1 (15.0 ppb) 1.8 2.1 Linearity solution-2 (30.0 ppb) 1.1 1.4 Linearity solution-3 (60.0 ppb) 1.2 1.4 APIs Amount in sample (ppb) NDMA NDEA Candesartan BLOQ BLOQ Irbesartan BLOQ BLOQ Losartan BLOQ BLOQ Olmesartan BLOQ BLOQ Valsartan 17.6 BLOQ Metformin BLOQ BLOQ The amount calculated in Metformin and 5 Sartan APIs is summarized in table 5. Table 5: Results for sample summary BLOQ: Below limit of quantitation.
Please fill out the survey Related Products Some products may be updated to newer models. GCMS-QP2020 NX Gas Chromatograph Mass Spectrometer AOC-30 Series Autoinjector / Autosampler Related Solutions Manufacturing, QA/QC Price Inquiry Product Inquiry Technical Service / Support Inquiry Other Inquiry Powered by TCPDF (www.tcpdf.org)