Content overflows the browser. Try zooming out (Ctrl + −) to see the full page. PDF Download
User Benefits Application News Introduction In recent years, hydrogen energy has attracted interest as a way to achieve carbon neutrality because it burns without CO 2 emissions. In particular, studies are underway on so-called “green hydrogen” that does not emit CO 2 even during its manufacturing process. A promising method for the production of green hydrogen is to generate hydrogen through artificial photosynthesis using solar energy and a photocatalyst. However, this technique still has the challenges of increasing solar energy conversion efficiency and reducing manufacturing costs. One approach suggested as an effective way to solve those problems is to build an artificial photosynthesis system that utilizes the long wavelength light, which has the highest intensity of sunlight. Photoreaction quantum yield, which refers to how efficiently photons are utilized, is commonly used as an index for the energy conversion efficiency of artificial photosynthesis systems. Calculating the photoreaction quantum yield requires determining the number of photons absorbed and the quantity of hydrogen generated. The former can be measured using Lightway photoreaction evaluation system and the latter using Nexis GC-2030 gas chromatograph. This article describes the use of the Lightway and Nexis GC-2030 systems to evaluate a visible light-responsive photocatalytic hydrogen generation system that uses an iridium complex with coumarin ligands as a photosensitizer. The excited iridium complex photosensitizer (PS) obtains an electron from the ascorbate ion (HAsc - ) to decrease the charge state of the cobalt (Co) complex (Co Ⅲ → Co Ⅱ ). That Co complex serves as a catalyst that promotes hydrogen ion (H + ) reduction. Note that when oxygen coexists, part of the energy obtained from the photosensitizer is consumed to generate singlet oxygen. To prevent oxygen contamination, the samples were bubbled with inert gas (N 2 ) for 30 minutes before measurement. The measurement conditions for the Lightway system used to measure the number of photons and the Nexis GC-2030 system used to quantitate how much hydrogen was generated are listed in Tables 2 and 3, respectively. A long-necked cell with a septum was used for this analysis. After using the Lightway system to measure the number of absorbed photons, 200 µL of the headspace gas present in the long-necked cell is collected with a gas-tight syringe and injected into the Nexis GC-2030 system. Evaluation of Iridium Complex-Based Photocatalytic Hydrogen Generation System for Artificial Photosynthesis Studies Photoreaction quantum yield, which is essential for evaluating the efficiency of artificial photosynthesis, can be accurately measured. Hydrogen can be detected by gas chromatograph with thermal conductivity detector (TCD), using argon as carrier gas. Yoshiyuki Tange and Emiko Shimbo Lightway™ Photoreaction Evaluation System / Nexis™ GC-2030 Gas Chromatograph Instrument: Lightway Measurement Interval: 5 sec Measurement Time: 5/10/20 min Measurement Wavelength: 460 nm Number of Irradiation Photons: 9.00 × 10 -8 einstein•s -1 Reagent Purpose Concentration Structural Formula Iridium Complex Photosensitizer (PS) 8 µM Fig. 1 (left) Cobalt Complex Water reduction catalyst 335 µM Fig. 1 (right) Sodium Ascorbate Sacrificial reagent *1 0.1 M – CH 3 CN-pH 4.5 Acetic Acid Buffer Solution Solvent – – Table 2 Conditions for Measuring the Number of Photons Absorbed Table 3 Measurement Conditions for Gas Quantitation Instrument: Nexis GC-2030 Injection Port Unit: SPL-2030 Detector: TCD-2030 Column: Micropacked ST 2 m × 1 mm I.D. (P/N: MP-01) (Input 250 m × 0.50 mm I.D. and df = 10 μm into software for flow calculation) Injection Volume: 200 µL (gas-tight syringe) Injection Port Temperature: 150 °C Injection Mode: Split (1:2) Carrier Gas: Ar, constant linear velocity mode (30 cm/s) Purging Flowrate: 3 mL/min Column Oven Temperature: 35 °C (2.2 min) Detector Temperature: 260 °C Detector Current: 30 mA Make-up Gas: Ar, 8 mL/min Fig. 1 Structural Formulas of Complexes (Left: Iridium Complex; Right: Cobalt Complex) Photocatalytic Hydrogen Generation System Details and Measurement Conditions The reagents used in the photocatalytic hydrogen generation system and their roles are indicated in Table 1 1) . Table 1 Roles and Concentrations of Reagents Used *1 Sometimes used to evaluate hydrogen generation in basic research of artificial photosynthesis systems. The structures of the respective complexes are shown in Fig. 1 and the reaction systems in Fig. 2. N N O O H O N N O H N Co Cl N S O O N + PF 6 - N S O O N N N Ir If the baseline no longer stabilizes after repeated analyses, heat the column at a high temperature or use a heating program after each analysis to drive off contaminants out of the column. Fig. 2 Iridium Complex-Based Photocatalytic Hydrogen Generation System Visible light Intersystem crossing
Application News www.shimadzu.com/an/ Shimadzu Corporation © Shimadzu Corporation, 2023 For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. See http://www.shimadzu.com/about/trademarks/index.html for details. Third party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “”. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. Before reaction 20 minutes after reaction started 1.052 0.996 477 Lightway and Nexis are trademarks of Shimadzu Corporation or its affiliated companies in Japan and/or other countries. Conclusion This article describes using a Lightway photoreaction evaluation system and Nexis GC-2030 gas chromatograph to evaluate the efficiency of a visible light-responsive photocatalytic hydrogen generation system, which has attracted attention within the artificial photosynthesis research field for achieving carbon neutrality. The results confirmed excellent quantum yield performance compared with preceding studies. The method can also be used to estimate the decrease in quantity of photosensitizer based on the change in the absorption spectra before and after reactions. Confirmation of Decrease in Photosensitizer Quantity The decrease in the iridium complex photosensitizer quantity was confirmed based on the change in the absorption spectrum before and after the reaction. Absorption spectra obtained using the Lightway system before and after the reaction are shown in Fig. 6. The absorbance at 477 nm, which is the peak from the iridium complex, was 1.052 before the reaction and 0.996 twenty minutes after the reaction. This indicates that absorbance decreased about 5 % during the reaction. Assuming that the decrease in absorbance is proportional to the decrease in iridium complex quantity, it can be inferred that the iridium complex quantity also decreased about 5 %. Φ 1 = Number of Hydrogen Generated / Number of Photons Absorbed … (1) Φ 2 = Number of Electrons Used in Reaction / Number of Photons Absorbed …(2) References 1) S. Takizawa et. al., Inorg. Chem. 2016, 55, 8723−8735. 2) S. De. Kreijger et. al., Inorg. Chem. 2022, 61, 5245−5254 Fig. 5 Relationship between Number of Absorbed Photons and Number of Generated Hydrogen Molecules. 0.0 0.5 1.0 1.5 2.0 min 0.00 0.25 0.50 0.75 Concentration 0 100000 200000 300000 Area 1.00 400000 Fig. 4 Calibration Curve of Hydrogen (0.1 %, 0.5 %, 1 %) R 2 = 0.9996 Calculation of Photoreaction Quantum Yield Accurate quantum yield can be calculated from the number of absorbed photons measured by Lightway and the number of generated hydrogen molecules measured by Nexis GC-2030. The relationship between the number of absorbed photons and the number of generated hydrogen molecules is shown in Fig. 5. This confirms excellent linearity between the number of absorbed photons and the number of generated hydrogen molecules. In this case, the following two formulas were used to calculate the quantum yield. The hydrogen concentration was determined by the calibration curve in Fig. 4. The volume of hydrogen generated was calculated based on the hydrogen concentration and the cell headspace volume. In addition, the hydrogen volume was converted to hydrogen mass assuming one mole of hydrogen per 22.4 L. Hydrogen Quantitation by Gas Chromatograph TCD was used as the Nexis GC-2030 detector and argon as the carrier gas. TCD detects target compounds based on their difference in thermal conductivity from the carrier gas. Therefore, argon is commonly used as a carrier gas for hydrogen analysis due to its large difference in thermal conductivity compared with hydrogen. An example of a chromatogram obtained from this measurement is shown in Fig. 3. The peak of hydrogen was detected at a retention time of 0.5 minutes. The calibration curve obtained by the analysis of the standard hydrogen gas samples is shown in Fig. 4. Fig. 6 Absorption Spectra of Iridium Complex Before and After Photocatalytic Hydrogen Generation Experiment Fig. 3 Chromatogram of Sample Analysis Obtained with Gas Chromatograph Hydrogen (Quantitative concentration: 0.61 %) First Edition: Aug. 2023 Acknowledgments We would like to express our sincere gratitude to Dr. Shinya Takizawa, Assistant Professor, Department of Basic Science, Graduate School of Arts and Sciences, The University of Tokyo, for providing the iridium and cobalt complexes used for measurements. Equation (1) has a value equivalent to the slope in Fig. 5, which results in a calculation of Φ 1 = 1.44 %. Assuming one photon is transferred per electron, two electrons are required to generate a hydrogen, resulting in a maximum quantum yield value of 50 % based on the definition in equation (1). With equation (2), given that two electrons are used per molecule of hydrogen, the slope in Fig. 5 is doubled to result in a calculation of Φ 2 = 2.88 %. That method results in a maximum quantum yield of 100 % for all photoreactions premised on one photon transfer per electron. When comparing quantum yield with previous researches, it is necessary to confirm which definition was used as the basis for calculating the yield. In reference 2), the quantum yield of photocatalytically generated hydrogen was measured based on an iridium complex with a ligand bond other than the coumarin ligand. In that case, the calculation is reported as Φ 2 = 0.13 % (446 nm), based on equation (2). A comparison showed that the method in this article produced far superior quantum yield, with about 22 times higher quantum yield than the method in reference 2). 01-00548-EN
Please fill out the survey Related Products Some products may be updated to newer models. Lightway PQY-01 Photoreaction Evaluation System Nexis™ GC-2030 Gas Chromatograph Related Solutions Clean Energy Artificial Photosynthesis Price Inquiry Product Inquiry Technical Service / Support Inquiry Other Inquiry Powered by TCPDF (www.tcpdf.org)