Application
News
www.shimadzu.com/an/
Shimadzu Corporation
© Shimadzu Corporation, 2023
For Research Use Only. Not for use in diagnostic procedures.
This publication may contain references to products that are not available in your country. Please contact us to check the availability of these
products in your country.
The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu.
See http://www.shimadzu.com/about/trademarks/index.html for details.
Third party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not
they are used with trademark symbol “TM” or “”.
Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.
The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its
accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the
use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject
to change without notice.
First Edition: Dec. 2023 01-00662-EN
Nexera, Shim-pack Scepter, and DUIS are trademarks of Shimadzu Corporation or its affiliated companies in Japan and/or other countries.
Fig. 3 shows the mass spectrum for the peak detected around
the retention time of 11 minutes. Multiply-charged ions with
charges from 17 to 22 were detected. The mass spectrum was
deconvoluted to estimate the molecular weight (Fig. 4). That
resulted in an estimated molecular weight of 21465.4, within a 1
Da margin of error with respect to the theoretical molecular
weight (21465.9).
Conclusion
A Nexera XS inert UHPLC system and an LCMS-2050 single
quadrupole mass spectrometer were used to analyze the
molecular weight of synthesized single-stranded DNA.
Generally, when estimating molecular weight using a
deconvolution function, the more multiply-charged ions that
can be obtained, the more reliable the molecular weight
estimation will be. As a result of deconvolution of the mass
spectrum for the detected peaks, it was possible to estimate the
molecular weight of the principal components of the
oligonucleotide therapeutic within a 1 Da margin of error from
the theoretical value.
The LCMS-2050 enables fast and highly sensitive analysis across
a wide mass range, while maintaining user-friendly operability
similar to LC systems. The system described above provides a
useful analytical tool for quality control of oligonucleotide
therapeutics.
Related Applications
1. Simple Analysis of Impurities in Oligonucleotide Therapeutics
Using a Single Quadrupole Mass Spectrometer, Application
News No.01-00656-EN
2. An Oligonucleotide Impurity Analysis Workflow Using
LabSolutions Insight™ Biologics Software, Application News
No.01-00595A-EN
Fig. 3 Mass Spectrum of the Synthetic DNA
Fig. 4 Deconvoluted Mass Spectrum
Acknowledgments
We are grateful to Dr. Yuuya Kasahara (National Institutes of
Biomedical Innovation, Health and Nutrition, Japan) for generously