Content overflows the browser. Try zooming out (Ctrl + −) to see the full page. PDF Download
User Benefits Application News Fig. 1 Chromatogram of Mixed Standard Sample of 8 Compounds (100 ppm) As representative compounds used in electrolytes, the 8 types of carbonic ester compounds listed in Table 2 were prepared. These compounds were diluted with dichloromethane, and 8- compound mixed standard samples were prepared for the 6 points of 10 mg/L, 25 mg/L, 50 mg/L, 100 mg/L, 200 mg/L, and 500 mg/L. Calibration curves were prepared and repeatability was confirmed using these standard samples. Analysis of Standard Sample Table 1 Analysis Conditions Table 2 Types of Carbonic Esters and Additives Used Diffusion of lithium ion batteries, which are used in electric vehicles (EVs) and power storage systems, has increased in recent years because this type of battery achieves high speed charging/discharging and long battery life. Lithium ion batteries consist of electrodes, separators, and an electrolyte, but among these components, the composition and purity of the carbonic ester and additives in the electrolyte are critical for maintaining the battery quality and performance. These compounds can be analyzed with a gas chromatograph (GC). The lithium ion battery market has expanded rapidly in recent years, and analysis of the electrolytes used in batteries is indispensable as a key element of quality control. In quality control, it is necessary to analyze as many samples as possible in a limited laboratory space. Under these conditions, one particularly effective option is the Shimadzu Brevis GC-2050, which boasts outstanding analysis performance combined with a space-saving design. This Application News article introduces an example in which several types of carbonic esters and additives which are frequently used in electrolytes were analyzed with a Brevis GC- 2050+FID detector. In this analysis, N 2 was used as the carrier gas. Introduction Carbonic esters and additives in lithium ion battery electrolytes can be analyzed with high separation and good repeatability by using N 2 as the carrier gas. The Brevis GC-2050+FID is the optimum instrument for routine analysis thanks to its space-saving design. Analysis of Carbonic Esters and Additives in Lithium Ion Battery Electrolytes Misato Ishimoto Brevis™ GC-2050 Gas Chromatograph Table 1 shows the analysis conditions. A PTFE syringe (P/N 221- 74469) was used. Analysis Conditions Model : Brevis GC-2050 Inj. temp. : 250 ˚C Inj. mode : Split 30:1 Carrier gas : N 2 , constant linear velocity (25 cm/s) Column : SH-I-5MS (P/N 221-75940-30) (30 m × 0.25 mm I.D., 0.25 μm) Column temp. : 40 ˚C (3 min) → 10 ˚C/min → 160 ˚C (5 min) Detector : FID FID temp. : 250 ˚C Makeup gas : N 2 , 24 mL/min H2 flow : 32 mL/min Air flow : 200 mL/min Compound name Abbreviation 1 Dimethyl carbonate DMC 2 Ethyl methyl carbonate EMC 3 Vinylene carbonate VC 4 Diethyl carbonate DEC 5 Fluoroethylene carbonate FEC 6 Ethylene carbonate EC 7 Propylene carbonate PC 8 1,3-propanesultone PS Fig. 1 shows the total chromatogram for the 100 ppm standard sample. Chromatogram Results of 8-Compound Mixed Standard Samples 1 DMC 2 EMC 3 VC 4 DEC 5 FEC 6 EC 7 PC 8 PS 1 2 3 4 5 6 7 8 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 17.0 18.0 19.0 min Fig. 2 shows the calibration curve results for the respective compounds. All compounds showed satisfactory linearity, with R 2 = 0.999 or higher. Table 3 shows the peak area repeatability (%RSD) for 5 repeated analyses (n = 5) at 10 mg/L. Good repeatability results were obtained for all compounds. Calibration Curve Results of 8-Compound Mixed Standard Samples EMC R 2 >0.9998 0 100 200 300 400 Conc. 0 25000 50000 75000 100000 125000 150000 Area DMC R 2 >0.9999 0 100 200 300 400 Conc. 0 10000 20000 30000 40000 50000 60000 70000 80000 Area DEC R 2 >0.9998 0 100 200 300 400 Conc. 0 25000 50000 75000 100000 125000 150000 175000 Area VC R 2 >0.9998 0 100 200 300 400 Conc. 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 Area
Application News www.shimadzu.com/an/ Shimadzu Corporation © Shimadzu Corporation, 2024 For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. See http://www.shimadzu.com/about/trademarks/index.html for details. Third party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “”. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. First Edition: Apr. 2024 01-00708-EN Quantitative Analysis of Electrolyte Samples Conclusion Brevis is a trademark of Shimadzu Corporation or its affiliated companies in Japan and/or other countries. Four commercially-available lithium ion battery electrolyte samples with different types of electrolytes and carbonic esters were analyzed. Table 4 shows the types of electrolytes, carbonic esters, and additives contained in each sample. The samples were analyzed at 1000x dilution with dichloromethane. If the samples are analyzed in the undiluted state, the effect of electrolyte precipitation will be excessive, and it will be necessary to increase number of insert and column maintenance procedures appropriately. It should be noted that the dispensing work was done in a glovebox to avoid the danger of reaction between moisture in the atmosphere and the Li-based electrolytes. Fig. 3 shows the chromatograms of the respective samples. Table 5 shows the quantitation values of the carbonic esters and additives prior to dilution with dichloromethane for each sample. The peak top numbers in the chromatograms in Fig. 3 correspond to the numbers in the No. column in Table 5. Chromatograms with excellent separation were obtained for a standard solution of 8 types of carbonic esters and additives which are widely used in the electrolytes of lithium ion batteries. Excellent results were also obtained for the linearity and repeatability of the calibration curves. The results of this analysis of commercially-available electrolyte samples demonstrated that the Brevis GC-2050 gas chromatograph is an easy-to-use tool for quantitative analyses. Fig. 2 Calibration Curves of 8 Compounds FEC R 2 >0.9998 0 100 200 300 400 Conc. 0 5000 10000 15000 20000 25000 30000 35000 40000 45000 50000 55000 Area EC R 2 >0.9999 0 100 200 300 400 Conc. 0 10000 20000 30000 40000 50000 60000 70000 80000 Area PS R 2 >0.9999 0 100 200 300 400 Conc. 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 110000 120000 Area PC R 2 >0.9999 0 100 200 300 400 Conc. 0 25000 50000 75000 100000 125000 150000 Area Table 3 Peak Area Repeatability (%RSD) in Repeated Analyses (n = 5) Compound name %RSD DMC 1.28 EMC 0.80 VC 1.03 DEC 1.39 FEC 1.73 EC 1.26 PC 1.16 PS 1.10 Table 4 Types of Actual Samples Electrolyte Carbonic ester/additive Sample 1 LiFSI DMC, EMC, EC Sample 2 LiFSI DMC, DEC, EC Sample 3 LiPF 6 DMC, EMC, EC Sample 4 LiPF 6 DMC, DEC, EC 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 min 1 2 6 <Sample 2> 1 4 6 <Sample 3> <Sample 4> 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 min 1 4 6 <Sample 1> 1 2 6 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 min 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 min Fig. 3 Chromatograms of 4 Types of Commercial Electrolyte Samples Table 5 Quantitation Values of 4 Types of Actual Samples (mg/mL) No. Compound Sample 1 Sample 2 Sample 3 Sample 4 1 DMC 278.7 284.1 291.2 301.9 2 EMC 283.5 - 294.9 - 3 VC - - - - 4 DEC - 277.6 - 290.3 5 FEC - - - - 6 EC 402.8 397.0 402.5 414.5 7 PC - - - - 8 PS - - - -
Related Products Some products may be updated to newer models. Brevis™ GC-2050 Gas Chromatograph SH-I-5MS Related Solutions Clean Energy Lithium-ion Battery Price Inquiry Product Inquiry Technical Service / Support Inquiry Other Inquiry Powered by TCPDF (www.tcpdf.org)