User Benefits Application News Fig. 3 Flow path diagram of flow synthesis monitoring Fig. 1 Nexera FV (for flow synthesis) and flow through vial An esterification reaction under acidic condition was investigated. Esterification by dehydration-condensation is a process in which a carboxylic acid reacts with an alcohol to form an ester, which is catalyzed by an acid. 3-phenylpropionic acid was used as the reactant of carboxylic acid and methanol as the alcohol, and AmberLyst 36WET, a strong acid catalyst, was packed in the reaction column and used for the reaction (Fig, 2). Analytical conditions Nexera FV introduces the reaction solution delivered from the flow synthesizer into the flow through vial for sampling. In this case, LC-40D pump and CTO-40C column oven of Shimadzu Nexera Series were used as the flow synthesizer and were connected to Nexera FV to introduce the reaction solution from the reaction column into the flow through vial (Fig. 4). The reaction solution was automatically injected from the flow through vial to HPLC according to the created analytical batch. In this study, on-line monitoring of the esterified reaction solution was performed by delivering 50 mmol/L phenylpropionic acid methanol solution through the reaction column (AmberLyst 36WET) heated to 60 ℃ at the flow rate of 0.1 mL/min (Fig. 3). In the pharmaceutical and fine chemical industries, there is an increasing demand to switch from conventional batch manufacturing for the sake of improvement of efficiency (labor and manpower savings), quality and safety, and reduction of environmental load. ICH-Q13 guidelines for continuous production of drug substances and drug products recommend the application of Process Analytical Technology (PAT) for the purpose of maintaining controlled conditions for manufacturing. Consequently, the demand for PAT is increasing. Nexera FV is an HPLC system setup for on-line analysis equipped with a flow through vial in the autosampler (Fig. 1). The system enables automated processes from continuous delivery of reaction solution into the flow through vial to resulting report creation of HPLC analysis. This article introduces an on-line monitoring of flow synthesis reactions using Nexera FV, taking an example of the esterification of carboxylic acid. Introduction On-line monitoring of flow synthesis reactions can be performed. Simple operation with dedicated software allows automatic execution of analysis at specific sampling intervals and automatic report generation. Reliable experimental system setup can be established using HPLC as a part of flow synthesis system. On-Line Monitoring of Flow Synthesis Reactions Using Nexera FV Ayano Tanabe, Katsumasa Sakamoto High Performance Liquid Chromatograph Nexera FV Fig. 2 Esterification reaction of phenylpropionic acid Reactant Product On-line monitoring with Nexera FV LabSolutions TM FV for easy creation of analytical batch LabSolutions FV, a dedicated on-line monitoring software, allows users to easily perform complicated procedures such as creating an analytical batch and entering operational settings during reaction monitoring (Fig. 5). The analytical batch is automatically created by simply entering information such as HPLC conditions and sampling interval, allowing to start on-line HPLC analysis without any difficulties. It also supports input of external signals and start of sampling at a specified time, making it possible to link with other systems. Fig. 4 System setup of flow synthesizer and Nexera FV Nexera TM FV Flow synthesizer Solvent delivery pump LC-40D Column oven CTO-40C Nexera TM FV
Application News www.shimadzu.com/an/ Shimadzu Corporation © Shimadzu Corporation, 2024 For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. See http://www.shimadzu.com/about/trademarks/index.html for details. Third party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “”. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. Fig. 7 Trend plot for phenylpropionic acid(reactant) and product First Edition: Sep. 2024 01-00779A-EN Analysis of reaction solution Conclusion Nexera, LabSolutions, and Shim-pack Velox are trademarks of Shimadzu Corporation or its affiliated companies in Japan and/or other countries. In this monitoring of the flow synthesis reaction, measurements were performed using the direct injection method, in which the reaction solution was injected directly from the flow through vial into the HPLC. Table 1 shows the HPLC analytical conditions, and Fig, 6(a) shows the chromatogram of the reaction solution (at 0 min) and Fig, 6(b) shows the chromatogram of the reaction solution (at 300 min). Phenylpropionic acid and product peaks were detected at 0.49 min and 1.15 min, respectively. Reaction monitoring was conducted from 20 to 960 minutes after the start of pumping, and it was confirmed that under these conditions, the esterified product was obtained constantly at 95~96% purity after 120 min. On-line monitoring of the esterification reaction of phenylpropionic acid by flow synthesis was performed using Nexera FV. Connecting the reaction system and the flow through vial, sampling and analysis was able to be performed automatically according to the analytical batch. In addition, the multi-data reporting function allowed reaction tracking on reactant and product by automatic generation of trend plot after analysis. Nexera FV and LabSolutions FV simplified analytical batch creation, automated sampling, and reporting. It results in a reduction of working time and increase of efficiency. Table1 HPLC conditions *1 P/N : 227-32001-02 Reactant 0.00 0.50 1.00 1.50 2.00 2.50 3.00 min 0 100 200 300 400 500 mAU Column : Shim-pack Velox C18 *1 ( 50 mm × 2.1 mm I.D., 1.8 µm ) Mobile phase A : 0.5% Formic acid in Water Mobile phase B Acetonitrile Time program (%B) : 30% (0 min)→95% (0.45-1.40 min)→ 30% (1.41-3.5 min) Flow rate : 0.8 mL/min Column temp. : 40 ℃ Injection vol. : 1 µL Detection : UV 254 nm 0.0 0.5 1.0 1.5 2.0 2.5 3.0 min 0 250 500 mAU Reaction product tracking using trend plot A trend plot of the variations in the peak areas of phenylpropionic acid and the reaction product based on the reaction monitoring results is shown in Fig.7, created using LabSolutions' Multi-Data Report *2 function. Using the multi-data report function, a report (Fig. 8) can be automatically created after all analyses are complete, allowing visualized confirmation of the yield and the variation of intermediate in the synthesis process. *2 Multi data report is a function equipped in LabSolutions DB/CS Fig. 8 Multi data report *2 Fig. 6(b) Chromatogram of reaction solution (After 300 min) Fig. 6(a) Chromatogram of reaction solution (0 min) Reactant Product Fig. 5 Setting screen of LabSolution FV Time(min) Yield Reactant Revision A: Oct. 2025
Please fill out the survey Related Products Some products may be updated to newer models. Nexera FV Ultra High Performance Liquid Chromatograph for On… Shim-pack Velox LC Columns HPLC Column Related Solutions Pharmaceutical and Biopharmaceutical Small Molecule Pharmaceutical Chemicals Price Inquiry Product Inquiry Technical Service / Support Inquiry Other Inquiry Powered by TCPDF (www.tcpdf.org)