Content overflows the browser. Try zooming out (Ctrl + −) to see the full page. PDF Download
User Benefits Application News LabSolutions Detect automates impurity peak detection and identification, improving the efficiency of impurity management. By coupling a single quadrupole mass spectrometer (LCMS-2050), mass information can be acquired as qualitative information for impurity peaks. Streamlining Impurity Management Using LabSolutions Detect Shinichi Fujisaki Anomaly Peak Detection Support Software In the pharmaceutical development process, the qualitative and quantitative analysis and appropriate management of impurities are essential to ensure product safety. For example, during active pharmaceutical ingredient (API) synthesis, various impurities are generated throughout multi-step synthetic routes from starting materials to the final API. Accordingly, the ICH guidelines¹⁾ define threshold levels at which impurity identification is required, and such impurities must be controlled within acceptable limits. In addition, stability testing of pharmaceuticals is conducted to evaluate time-dependent changes under various exposure conditions in order to ensure product safety and determine shelf life. Degradation products generated under these exposure conditions must also be appropriately managed to monitor such changes over time. However, when multiple impurities and degradation products are managed manually, tasks such as peak detection and peak identification carry the risk of missed detections and human error. LabSolutions Detect, an anomaly peak detection support software, automates peak detection and peak identification for arbitrary peaks, including impurities and degradation products. In this article, case examples are presented in which peak detection and peak tracking were automated for multiple model samples assuming different impurity profiles, thereby streamlining impurity management. Furthermore, the combined use of a single quadrupole mass spectrometer (LCMS- 2050) demonstrates that mass information can be acquired as qualitative information for each peak. Introduction Fig. 2 shows the results of automatic impurity detection and identification performed by LabSolutions Detect in accordance with the criteria set as detection thresholds (Fig. 1). The blue- framed area in Fig. 2 shows the results for the control, in which three known compounds (Known 1–3) were detected. The red- framed area in Fig. 2 shows the results for Samples 1–5, where the area percentages of the detected impurities are automatically entered as red values. In addition, because peak identification is also automated, identical impurities are displayed in the same column. For example, in Sample 2, two impurities (New 2 and New 3) were detected, and New 2 was also detected in Samples 3 and 4. Furthermore, for the three known compounds (Known 1– 3), the area percentages were automatically entered for Samples 1–5, indicating that these compounds were detected in all samples. Fig. 3 shows the individual chromatograms for Samples 1–5, in which automatically detected impurity peaks are highlighted in red, facilitating the identification of unknown impurities. In addition, a comparison of the chromatograms for Samples 1–5 is shown in Fig. 4. By combining these results with those shown in Fig. 2, the number of impurities detected across multiple chromatograms and their elution times can be visually confirmed. Moreover, mass information obtained using the LCMS-2050 can be utilized as qualitative information for each impurity. Streamlining Impurity Management by LabSolutions Detect Ultra High Performance Liquid Chromatograph As target compounds, a control sample free of impurities and five model samples assuming different impurity profiles were used; the model samples were artificially prepared as mixtures of different low-molecular-weight pharmaceuticals. The analytical conditions are summarized in Table 1. LabSolutions Detect automatically performs peak detection according to predefined criteria. In this study, the upper limit of the area percentage for impurity peaks was set to 0.1%, and peak detection and peak tracking were automatically performed for Samples 1–5 (Table 1). Target Compounds Table 1 Analytical Conditions Fig. 1 Criteria for Unknown Impurities Control : Benzoic acid, Naproxen, Probenecid Sample 1 : Control with added quinidine Sample 2 : Control with added antipyrine, hydrocortisone Sample 3 : Control with added antipyrine, furosemide Sample 4 : Control with added antipyrine, indometacin Sample 5 : Control with added indometacin Mobile phase Pump A : 0.1% formic acid in water Pump B : Acetonitrile Column : Shim-pack Scepter C18-120 *1 (100 mm × 3.0 mm I.D., 1.9 µm) Injection Vol. : 0.5 µL *1 P/N : 227-31013-03 Criteria of peak detection : Upper limit of impurity (area %) : 0.1 LC Conditions B Conc. : 5% (0 min)→90% (5 min)→5% (5-10 min) Column Temp. : 40 °C Flow rate : 0.7 mL/min Detection : 254 nm (SPD-M40, STD cell) System : LCMS-2050 Ionization : ESI/APCI (DUIS), positive and negative mode Mode : SCAN (m/z 80-1000) Nebulizing gas flow : 2.0 L/min Drying gas flow : 5.0 L/min Heating gas flow : 7.0 L/min DL Temp. : 200 °C Desolvation Temp. : 450 °C Interface voltage : +3.0 kV / -2.0 kV MS Conditions System : Nexera X3
Application News www.shimadzu.com/an/ Shimadzu Corporation © Shimadzu Corporation, 2026 For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. See http://www.shimadzu.com/about/trademarks/index.html for details. Third party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “”. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. First Edition: Jun. 2026 01-01221-EN LabSolutions, Nexera, DUIS and Shim-pack Scepter are trademarks of Shimadzu Corporation or its affiliated companies in Japan and/or other countries. By automating impurity peak detection and identification using LabSolutions Detect, the risk of missed peaks and human identification errors can be reduced. In addition, coupling a single quadrupole mass spectrometer (LCMS-2050) enables acquisition of mass information as qualitative data for each peak. Conclusion <References> 1) International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use : Q3A, Q3B Fig. 2 Impurity Management by LabSolutions Detect (area percentages of detected impurities are automatically entered as red values) Control Sample 1 Sample 2 Sample 3 Sample 4 Sample 5 Known 1 Known 2 Known 3 New 1 New 2 New 3 New 4 New 5 Known 1 Known 2 Known 3 New 1 New 2 New 3 New 4 New 5 Sample 1 Sample 2 Sample 3 Sample 4 Fig. 4 Comparison of Chromatograms for Control and Samples 1–5 (5) Sample 5 (4) Sample 4 (3) Sample 3 (2) Sample 2 (1) Sample 1 (0) Control 3 4 5 min AU 0 0.5 1.0 (5) (4) (3) (2) (1) (0) Known 2 Known 3 Known 1 New 1 m/z 325 [M+H] + New 2 m/z 189 [M+H] + New 3 m/z 363 [M+H] + New 4 m/z 329 [M-H] - New 5 m/z 358 [M+H] + Consequently, this approach contributes to improved efficiency and reliability in impurity management. Fig. 3 Chromatograms of Samples 1–5 (automatically detected impurities are highlighted in red) Sample 5
Please fill out the survey Related Products Some products may be updated to newer models. LabSolutions Detect Anomaly Detection Support Software Nexera Series Ultra High Performance Liquid C… Ultra High Performance Liquid Chromatograph LCMS-2050 High-Performance Liquid Chromatograph Mass Spectro… Related Solutions Pharmaceutical and Biopharmaceutical Small Molecule Pharmaceutical Price Inquiry Product Inquiry Technical Service / Support Inquiry Other Inquiry Powered by TCPDF (www.tcpdf.org)