ICPMS-2030
Inductively Coupled Plasma Mass Spectrometer
With its newly developed collision cell and optimized internal structure, the ICPMS-2030 provides superior sensitivity. At the same time, thanks to the adoption of its proprietary mini-torch unit and provision of an Eco mode, the quantity of argon gas needed for analyses has been greatly reduced to the industry's lowest levels. As a result, low running costs are assured. The Development Assistant function of the software automatically sets the optimal analysis conditions for quantitative analysis. Then, after measurements are complete, the Diagnosis Assistant function automatically checks the validity of the necessary data. While reducing the burden on the user, the efficiency of analyses is enhanced and the reliability of the data can be increased. It complies with FDA 21 CFR Part 11.
Features
-
The Development Assistant simplifies the process of developing analytical methods. The Diagnosis Assistant automatically diagnoses spectral interference. Together, they provide analytical results with exceptionally high reliability.
-
Achieve High-Sensitivity and Low-interference Analyses Using Newly Developed Collision Cell
-
Unique Combination Eco Mode/Mini-Torch Reduces Running Cost by Dramatically Reducing Gas ConsumptionIn addition to lower running costs, the environmentally-friendly mini-torch plasma unit, developed by Shimadzu, minimizes the energy (electricity) ...
-
By combining this software with ICPMS-2030 connected to a laser ablation instrument, sample measurement and data output in a format compatible with imaging data analysis software are possible.
Videos
-
ICPMS 2030 Inductively Coupled Plasma Mass Spectrometer -Short Version-
-
ICPMS 2030 Inductively Coupled Plasma Mass Spectrometer
News / Events
-
New Video: The Cabbage Core, Trash or Treasure?
Most people throw out the cabbage core when cooking, but is the core really just trash or actually a hidden treasure of nutrients?
-
New Video: ICPMS-2040/2050 ProActive Rinsing
ProActive Rinsing can shorten the analysis time by sharting the rinsing sequence in advance. While measuring multiple samples, the rinsing sequence can be started early by sending the autosampler probe to rinse while collecting data using sample already in the suction line. This greatly reduces measurement time and conserves sample.
-
New Video: ICPMS-2040/2050 Extended Rinsing
The extended rinsing function automatically performs an additional rinse sequence when a target element exceeds a predetermined upper limit. A second rinse solution can be used in the additional rinsing sequence to improve rinsing effectiveness. Consequently, carryover is eliminated to ensure high-quality data.
-
Shimadzu has released the ICPMS-2040 Series / ICPMS-2050 Series, Inductively Coupled Plasma Mass Spectrometry
ICPMS-2040/ 2050 Series has achieved a harmonious blend of environmental-friendliness and analytical performance.
-
The Shimadzu LCMS-2050 High-Performance Liquid Chromatograph Mass Spectrometer and the AA-7800 series of atomic absorption spectrophotometers have received the Red Dot Design Award 2023.
The Shimadzu LCMS-2050 High-Performance Liquid Chromatograph Mass Spectrometer and the AA-7800 series of atomic absorption spectrophotometers have received the Red Dot Design Award 2023.
-
Biodegradable Plastics
In order to reduce plastic waste, the development of eco-friendly alternative materials is being promoted. As an alternative, biomass plastics and biodegradable plastics are becoming more widely available. Biodegradable Plastics are plastics that are decomposed into low-molecular compounds by microorganisms in the environment. So they break down easily in nature, which is an opposite characteristic of petroleum-based plastics.