Last update: December 5, 2022 GMT

Glass insert for packed column
Name P/N Qty Remarks Applicable models
Glass insert for packed column 1 For 2.6 dia. Columns 2014
14
17*1
Glass insert for packed column 1 For 3 dia. Columns 2014
14
Glass insert for packed column 5 For 3 dia. Columns 2014
14
Glass insert for packed column 5 For 2.6 dia. Columns 2014
14

*1 GC-17 OCI requires an additional adapter (P/N: 221-42222-91).

Glass Insert for OCI / PTV
Name P/N Qty Remarks Applicable models
PTV 1 Quartz 2010
2010 Plus*2
PTV 5 for AOC-MEPS™ system, deactivated, with wool 2010
2010 Plus*2
Simple On-column 1 2010
2010 Plus*2
Simple On-column 1 Deactivated 2010
2010 Plus*2

*2 GC-2010 OCI requires an additional adapter (P/N: 221-49298-91).

Glass insert for capillary column
Name P/N Appearance Qty Remarks Applicable models
Direct
WBI
221-75197 5 Deactivated, with wool (95 mm, WBI) 2014
2010
2010 Plus
Direct
WBI
221-41599 1 Wide bore (95 mm, WBI) 2014
2010
2010 Plus
18A MF MT
1700
17A
Direct
WBI
221-41599-84 5 Wide bore (95 mm, WBI) 2014
2010
2010 Plus
18A MF MT
1700
17A
Direct
WBI
221-38107 1 (139 mm, for WBC attachment) 14A
14B
Direct
WBI
221-38151-04 1 (120 mm, for wide bore injection unit with septum purge) 14A
14B
Split/
Split-
less
221-75193 5 Deactivated, with wool (95 mm, SPL) 2010
2010 Plus
Split/
Split-
less
221-75194 5 Deactivated (95mm, SPL) 2010
2010 Plus
Split/
Split-
less
221-75195 5 Deactivated, with wool (95mm, SPL) 2014
Split/
Split-
less
221-41444-05 5 Deactivated (95m, SPL) 2014
Split/
Split-
less
221-75187 5 Deactivated, needle onto wool (95m, SPL) 2014
2010
2010 Plus
Split/
Split-
less
221-75191 5 Deactivated, needle into wool (95m, SPL) 2014
2010
2010 Plus
Split/
Split-
less
221-75188 5 Deactivated, needle onto wool (95m, SPL) 2014
2010
2010 Plus
Split/
Split-
less
221-75189 5 Deactivated, needle into wool (95m, SPL) 2014
2010
2010 Plus
Split/
Split-
less
221-75190 5 Deactivated (95m, SPL) 2014
2010
2010 Plus
Split-less 221-41544 1 (95mm, SPL) 2025
2014
2010
2010 Plus
18A PFsc
1700
17A
Split-less 221-41544-84 5 (95mm, SPL) 2025
2014
2010
2010 Plus
18A PFsc
1700
17A
Split-less 221-75192 5 Deactivated (95mm, SPL) 2014
2010
2010 Plus
Split-less 221-32544 1 (99m, SPL) 14A
14B
Split 221-41444 1 (95mm, SPL) 2025
2014
2010
2010 Plus
18A PFsc
1700
17A
Split 221-41444-84 5 (95mm, SPL) 2025
2014
2010
2010 Plus
18A PFsc
1700
17A
Split 221-37574-01 1 (99mm, SPL) 14A
14B
Glass insert (for capillary column)
Name P/N Appearance Qty Remarks Applicable models
Split 221-41444-01 1 (95mm,SPL) TQ8040
TQ8050
TQ8030
QP2020
QP2010 Ultra
QP2010 SE
QP2010
QP2010 Plus
PARUM2
2025
2014
2010
2010 Plus
18A PFsc
1700
17A

Supplementary keywords: Gas chromatograph, GC, GC-8A, GC8A, GC-14A, GC14A, GC-14B, GC14B, GC-17A, GC-2010, GC2010, GC-2014, GC2014, splitless, split, direct injection, WBI, SPL, septum, insert, ferrule, O-ring