Shimadzu GC Driver for Waters Empower - Specs

Shimadzu GC Driver

Controllable Hardware

[GC Unit]
Nexis GC-2030, Brevis GC-2050, GC-2010 Plus, GC-2010 Pro, GC-2010, GC-2014, GC-2014C

[Options]
AOC-30i, AOC-20i (Plus) autoinjector, AOC-20s (U) autosampler, HS-20 (NX)/HS-10 headspace sampler

 

Nexis GC-2030 and Brevis GC-2050

Sample Injector GC-2030: SPL-2030, WBI-2030, OCI-2030 (NX), PTV-2030, SINJ-2030, SPI-U (1.0)
GC-2050: SPL-U (1.0), PTV-U (1.0), WBI-U (1.0), OCI NX-U (1.0), SINJ-U (1.0), SPI-U (1.0)
Detector GC-2030: FID-2030, TCD-2030, ECD-2010 Exceed, FPD-2030, FTD-2030, BID-2030, SCD-2030, PTCD-2030, AB BOARD
GC-2050: FID-U(1.0), FPD-U(1.0), ECD-2010 Exceed U, FTD-U(1.0), BID-U(1.0), STCD-U(1.0), AB BOARD
Advanced Flow Technology GC-2030: Backflush, detector splitting, detector switching, heart-cut system
GC-2050: Backflush, detector splitting
Additional Temperature Controller GC-2030: Auxiliary temperature control unit
GC-2050: Auxiliary temperature control unit
Additional Flow Controller GC-2030: APC (3 auxiliary channels), APC (1 auxiliary channel)
GC-2050: APC (3 auxiliary channels), APC (1 auxiliary channel)
Options GC-2030: Gas selector, Low-temperature control solenoid valve set CRG-2030,External equipment control relay PGC-2030, PRG Box
GC-2050: Gas selector, Low-temperature control solenoid valve set CRG-2030, PRG-2030, PRG BOX

 

GC-2010 (Plus/Pro) and GC-2014 (C)

Sample Injector GC-2010 (Plus/Pro): SPL-2010 (Plus), WBI-2010 (Plus), OCI/PTV-2010 (Plus)
GC-2014 (C): SPL-2014, WBI-2014, DINJ-2014, SINJ-2014
Detector GC-2010 (Plus/Pro): FID-2010 (Plus), TCD-2010 (Plus), ECD-2010 Exceed, ECD-2010 (Plus), FPD-2010 (Plus), FTD-2010 (Plus), BID-2010 Plus, AB BOARD
GC-2014 (C): FID-2014, TCD-2014, ECD-2014, FPD-2014, FTD-2014 (C), AB BOARD
Additional temperature controller GC-2030: Auxiliary temperature control unit
GC-2050: Auxiliary temperature control unit
Additional flow controller APC (3 auxiliary channels), AMC (2 auxiliary channels)
Note : AMC is an option for the GC-2014.
Options Low-temperature control solenoid valve set: CRG-2010
External unit control relay: PRG-2010 (Plus), PRG BOX

 
* Dual-injection systems are not supported.
* Up to four Shimadzu GC units can be controlled on one data acquisition server (e.g. LAC/E32).
* Both the Shimadzu LC driver and Shimadzu GC driver for Empower can be installed on one computer or data acquisition server (e.g. LAC/E32).
* A Shimadzu instrument and third-party instrument cannot be connected to the same data acquisition server (e.g. LAC/E32) at the same time. Provide a data acquisition server dedicated for Shimadzu instruments.

{"title":"Specification Sheet Downloads","description":"Download the latest specification sheets.","source":"product","key":3202,"max":30,"filter_types":["spec_sheet"],"link_title":"View other Downloads","link_url":""} {"title":"Downloads","description":"Download the latest brochure.","source":"product","key":3202,"max":30,"filter_types":["brochures"],"link_title":"View other Downloads","link_url":"","pdf_links":[]}