User Benefits
Application
News
Introduction
Ethanol is a psychoactive and toxic substance that can cause
dependence and is associated with neuropsychiatric disorders,
cancers, cardiovascular disease, pancreatitis, and alcoholic liver
disease. The underlying pathology of alcohol-induced diseases,
particularly liver disease, involves a complex interplay of factors
including alcohol metabolism, inflammation and oxidative
stress, ultimately leading to liver damage, fibrosis, and cirrhosis.
In this paper, a method developed for the untargeted
metabolomics analysis of biological tissues and biofluids and
was applied to study the metabolic effects of ethanol exposure
in the liver using a mouse model.
Table 1 Analytical conditions
Study design
Metabolic profiles of liver tissue extracts from mice exposed to
ethanol were compared to un-dosed controls. C57BL/6 Mice
were subjected to a short-term model for exposure to ethanol (8
un-dosed controls and 8 treated over an 11-day duration).
Exposure to ethanol was achieved by feeding animals, ad
libitum, with the Lieber-DeCarli ethanol diet, containing 5%
extra pure ethanol. The study was carried out in accordance
with EU and National ethical guidelines and was approved by
the Aristotle University of Thessaloniki.
The study was designed to exemplify a high-resolution LC-
MS/MS data acquisition method developed for routine, robust
metabolomics research requiring minimal MS expertise which
can be applied to the untargeted metabolomics studies of
biological tissues and biofluids. The method is suitable for the
LCMS-9030 and LCMS-9050 (Fig. 1) QTOF instruments and offers
flexibility to work with both data independent acquisition (DIA)
or data dependent acquisition (DDA). In this application, DIA
was applied to an untargeted approach, capturing MS/MS for all
detectable features in all samples.
Fig. 1 LCMS-9050 QTOF system
LC/QTOF untargeted analysis of tissues
Livers were collected post-mortem and extracted in methanol:
isopropanol: water (3:3:1, v/v/v) at a ratio of 1.3mg tissue/µL
solvent. Supernatants were evaporated to dryness and
reconstituted in methanol for LC/QTOF analysis at a dilution of 1
in 20. For untargeted metabolomics analysis, high resolution
UHPLC-MS/MS data were acquired using TOF-MS and DIA-
MS/MS in both positive and negative ESI (Table 1) following
C18-reversed phase LC separation.
Preparation of quality control (QC) samples was performed for
assessing the quality of the acquired data following the
metabolomics Quality Assurance and Quality Control
Consortium (mQACC) recommendations
1
. QCs were prepared
by combining equal aliquots of each sample.
Untargeted Metabolomics Analysis of Ethanol
Exposure in Liver Using LC/QTOF
Emily Armitage
1
, Alan Barnes
1
, Olga Deda
2
, Christina Virgiliou
2
, Neil Loftus
1
, Helen Gika
2
, Ian
Wilson
3
1 Shimadzu Corporation, Manchester, UK, 2 Aristotle University of Thessaloniki, Greece, 3 Imperial College, London, UK
High Performance Liquid Chromatograph Mass Spectrometer
Untargeted metabolomics workflow for High-Resolution LC/QTOF (applicable to LCMS-9030 and 9050).
Applying an LC/QTOF method with fast scanning MS/MS to an untargeted metabolomics workflow to identify metabolic profiles
in biological tissue samples.
The workflow delivers an end-to-end solution for untargeted metabolomics research requiring minimal prior experience.
UHPLC: Nexera X2
Column C18 reversed-phase column (2.1x100 mm,
1.7 µm);
maintained at 50 °C
Flow Rate 0.4 mL/min
Mobile Phase A: Water + 0.1% formic acid
B: Acetonitrile + 0.1% formic acid
Rinse (R0/R1/R2) IPA/MeOH/MeCN/H
2
O (1:1:1:1) + 1% formic
acid
Gradient 2% B (0-1min); 40% B (2 min); 90% B (25 min,
Curve -3); 100% B (27.5-31 min); 2% B (31.01-
35 min)
Injection 0.5 µL; autosampler temperature 4 °C
Mass Spectrometer: LCMS-9030
Interface 300 °C, 1.5 kV (ESI+) / -3.0 kV (ESI-)
Heat block, DL 400 °C, 250 °C
Gas flow rates Nebulizing gas 3 L/min;
Heating gas 10 L/min;
Drying gas 15 L/min
CID gas pressure 230 kPa
MS TOF-MS (m/z 100-1000)
MS/MS 45 DIA-MS/MS (m/z 40-1000;
precursor isolation 20 Da; collision energy
spread 5-55 V)
Total cycle time
(MS and MS/MS)
1 second