Application
News
Results
To increase the metabolome coverage in untargeted tissue
metabolic profiling studies and to ensure high reporting
confidence requires more than one analytical approach.
Reversed-phase based DIA-MS/MS methods are powerful,
robust tools for highly positive metabolite identification.
However, identifying highly polar metabolites with high
confidence is challenging. As highlighted in Figure 1, the
application of a generic analytical reversed-phase LC-MS/MS
method results in a high metabolome coverage and has been
applied to the untargeted metabolomics analysis of biofluids
and tissues.
However, in metabolomics studies which report early eluting
features as significant, a HILIC method was specifically
developed to further increase reporting confidence using the
same precursor and data-independent MS/MS acquisition (DIA)
methods as applied with a reversed-phase UHPLC separation.
The HILIC method resulted in the separation of highly polar
features with minimal variance in retention time throughout a
metabolomics batch analysis (retention time variance was
typically less than 0.25% within a batch of tissue sample analysis
n=55; pooled QC and tissue extracts, Table 2 and graphically
represented in Figure 2).
UHPLC: Nexera X2
Reversed phase:
Column C18 (2.1x100 mm, 1.7 µm);
column maintained at 50 ˚C
Flow Rate 0.4 mL/min
Mobile Phase A: Water + 0.1% formic acid
B: Acetonitrile + 0.1% formic acid
Rinse (R0/R1/R2) IPA/MeOH/MeCN/H
2
O(1:1:1:1) + 1% formic
acid
Gradient 2% B (0-1min); 40% B (2 min); 90% B (25 min,
curvi-linear gradient); 100% B (27.5-31 min);
2% B (31.01-35 min)
Injection 0.5 µL; autosampler temperature 4 ˚C
HILIC:
Column Shim-pack Velox HILIC (2.1x100 mm
2.7 µm, PN: 227-32025-03);
column maintained at 40 ˚C
Flow Rate 0.3 mL/min (0-13 min); 0.4 mL/min (13-17
min); 0.3 mL/min (17-18 min)
Mobile Phase A: Water + 10 mM ammonium formate +
0.1% formic acid
B: Acetonitrile:water [92:8] + 10 mM
ammonium formate + 0.1% formic acid
Rinse (R0/R1/R2) IPA/MeOH/MeCN/H
2
O + 1% formic acid
Gradient 98% B (0-1.5 min); 65% B (11 min); 10% B
(12.5-14 min); 98% B (14.25-18 min)
Injection 0.5 µL; autosampler temperature 4 ˚C
Mass Spectrometer: LCMS-9030
Interface 300 ˚C, 1.5 kV (ESI+) / -3.0 kV (ESI-)
Heat block, DL 400 ˚C, 250 ˚C
Gas flow rates Nebulizing gas 3 L/min;
Heating gas 10 L/min;
Drying gas 15 L/min
CID gas pressure 230 kPa
MS TOF-MS (m/z 60-1000)
MS/MS 27 DIA-MS/MS (m/z 40-1000;
precursor isolation 35 Da; collision energy
spread 5-55 V
Total cycle time
(MS and MS/MS)
0.991 seconds
Table 1. Analytical conditions
Materials and Methods
Multiple tissue types from different metabolomics studies were
analysed using a standardised reversed-phase LC/QTOF method
and a HILIC LC/QTOF method. Tissue extract samples were
reconstituted in 90% acetonitrile. Tissues included brain, liver,
pancreas, gut, caecal tissue and faecal gut content from several
murine metabolomics studies. The HILIC method was
developed to selectively analyse highly polar metabolites.
Samples were analysed using the conditions detailed in Table 1.
Data were processed using LabSolutions Insight software to
consider a panel of 225 metabolite targets including lipid
distributions (LPCs, LPEs, MGs, fatty acids, fatty acid conjugates
and fatty amides) and polar metabolites (nucleotides, amino
acids, purines, pyrimidines). Data were compared against an in-
house metabolomics library (acquired using authentic reference
material, research use only) for high reporting confidence.
Library MS/MS spectra were generated using targeted MS/MS
with unit mass resolution and a collision energy spread of 5-55 V.
Product ion spectra were corrected to theoretical accurate mass
values using the Insight Assign application. Spectra were
acquired in positive and negative ion modes, first using the
reversed-phase method, then retention time mapped to a
Shim-pack Velox HILIC separation.
Metabolite Rt variance
%RSD
HILIC Rt and m/z (positive ion)
Adenine
Creatinine
Tryptophan
Phenylalanine
Trimethylglycine
Arginine
0.81%
1.18%
0.58%
0.52%
0.20%
0.12%
1.875 mins; m/z 136.0618
3.206 mins; m/z 114.0662
5.259 mins; m/z 205.0972
5.460 mins; m/z 166.0863
7.766 mins; m/z 118.0863
9.401 mins; m/z 175.1190
Table 2. Variance of retention time for metabolites detected in tissue matrix
extracts using HILIC. Data include extracts from brain, caecal, gut, liver,
pancreas, faecal gut content and plasma. The RT stability with this method is
high despite the wide variance in biological matrix.
RT (min)
0 2 4 6 8 10 12 14
RT (min)
0 2 4 6 8 10 12 14
Adenine
Arginine
Creatinine
Tryptophan
Phenylalanine
Trimethylglycine
HILIC separation
Reversed-phase separation
Fig.2 Chromatographic separation of adenine, creatinine, tryptophan,
phenylalanine, trimethylglycine and arginine in pancreas tissue extract by
HILIC and reversed-phase. Peaks are displayed to a ±5ppm mass tolerance,
and the same colours are used for each metabolite in HILIC or reversed-phase.