MOC63u
Unibloc Moisture Analyzer
Excellent performance for a wide variety of applications in multiple industries

In many fields, a moisture analyzer is a necessary tool for quality control requirements. With the MOC63u, you can easily obtain accurate data. Simply place material on the pan and shut the cover. The MOC63u will start to measure. The MOC63u adapts to various materials and increases your work efficiency.
Features
-
Long-life and high power halogen heater provides quick and accurate measurement. The temperature can be changed from 50 degrees to 200 degree Celsius.
You can check sample status from window while measurement. -
A built-in USB port is equipped as standard.
The measure results can be transferred by USB cable. If connect with PC by USB, needs USB driver. Please download from here. -
A total of five modes makes this balance compatible with a variety of sample measurements.
Ending modes: Automatic ending mode
Automatically ends measurement when moisture loss over the previous 30 seconds becomes smaller than specified percentage.
Downloads
Download the latest brochure.
Movies
-
MOC63u
News / Events
-
Latest issue of Shimadzu Journal, featuring Forensics/Toxicology, has come out.
The triple quadrupole mass spectrometer is widely used in various application fields to quantify the trace amount of compounds in real world samples because of its excellent sensitivity and selectivity. In order to achieve lower limit of quantitation, many researchers have been developing new desolvation technologies at either ESI sprayer or MS inlet.
Here, we report the higher sensitive triple quadrupole mass spectrometer equipped with novel desolvation devices such as addition of the heated gas blowing along with electrospray and the heated multi-orthogonal ion path mounted at the inlet of mass spectrometer. The combination of the heated gas at ESI and heated multi-orthogonal ion path enhanced desolvation efficiency which resulted in low femto-gram limit of quantitation.
Several commercially available drug samples (Reserpine, Verapamil, Alprazolam, Carbamazepine, Cilostazol, Lidocaine, Fluticasone and Testosterone) were prepared for the sensitivity evaluation of higher sensitive triple quadrupole mass spectrometer equipped with the modified ESI source and the heated multi orthogonal ion path. All the samples were analysed by the Multiple Reaction Monitoring (MRM). MRM parameters including MRM transitions and collision energy as well as compound dependent ion transfer voltages were optimised through automatic MRM optimization functionality incorporated in LabSolution software (Shimadzu Corporation, Kyoto, Japan).The temperatures of heated gas and heated multi-orthogonal ion path were optimised for each sample.
Using modified ESI source and the heated multi orthogonal ion path helped to deliver a limit of quantitation for all eight drugs below 5 fg/uL. The temperature of heated gas and heated multi-orthogonal ion path were independently optimised for each sample with the range of 200 to 500 degree C and 150 to 300 degree C respectively. The ion intensity of reserpine was increased 8 times with the heated gas and 4 times with heated multi-orthogonal ion path operated at 300 degree C. Besides larger volume of Ion was introduced into the mass spectrometer by the effective desolvation, the base line noise was maintained at reasonably low level as the noise derived from neutral droplet or unwanted ions were strongly reduced in the multi orthogonal region heated at high temperature, and resulted in excellent signal to noise ratio which achieved low femto-gram sensitivity. -
New "AP225W" Semi-micro Analytical Balance Enables Measurements up to 220 g on the Order of 0.01 mg
Faster Response and Higher Stability
-
Find the newest issue of the Shimadzu Journal, featuring Material Science, here.