SH-I-1MS

- Non-polar phase: Crossbond™ 100% dimethyl polysiloxane
- Tested and guaranteed for ultra-low bleed; improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
- General-purpose columns for arson accelerants, essential oils, hydrocarbons, pesticides, PCB congeners (e.g., Aroclor mixes), sulfur compounds, amines, solvent impurities, simulated distillation, oxygenates, gasoline range organics (GRO), refinery gases.
- Equivalent to USP G2 phase.
- Similar phases: HP-1ms UI, HP-1ms, DB-1ms UI, DB-1ms, Ultra-1, VF-1ms, SPB-1, Equity-1
P/N | ID | df (Film Thickness) | Length | Temp. Range |
---|---|---|---|---|
227-36001-01 | 0.15 mm | 0.15 μm | 20 m | -60 to 330/350°C |
227-36002-01 | 0.15 mm | 2.00 μm | 20 m | -60 to 330/350°C |
221-75921-20 | 0.18 mm | 0.18 μm | 20 m | -60 to 330/350°C |
227-36003-01 | 0.18 mm | 0.36 μm | 20 m | -60 to 330/350°C |
227-36004-01 | 0.20 mm | 0.33 μm | 25 m | -60 to 330/350°C |
227-36004-02 | 0.20 mm | 0.33 μm | 50 m | -60 to 330/350°C |
227-36005-01 | 0.25 mm | 0.25 μm | 15 m | -60 to 330/350°C |
221-75923-30 | 0.25 mm | 0.25 μm | 30 m | -60 to 330/350°C |
227-36005-02 | 0.25 mm | 0.25 μm | 60 m | -60 to 330/350°C |
227-36006-01 | 0.25 mm | 0.50 μm | 15 m | -60 to 330/350°C |
227-36006-02 | 0.25 mm | 0.50 μm | 30 m | -60 to 330/350°C |
221-75924-60 | 0.25 mm | 0.50 μm | 60 m | -60 to 330/350°C |
227-36007-01 | 0.25 mm | 1.00 μm | 15 m | -60 to 330/350°C |
227-36007-02 | 0.25 mm | 1.00 μm | 30 m | -60 to 330/350°C |
227-36007-03 | 0.25 mm | 1.00 μm | 60 m | -60 to 330/350°C |
227-36008-01 | 0.32 mm | 0.25 μm | 15 m | -60 to 330/350°C |
221-75926-30 | 0.32 mm | 0.25 μm | 30 m | -60 to 330/350°C |
227-36008-02 | 0.32 mm | 0.25 μm | 60 m | -60 to 330/350°C |
227-36009-01 | 0.32 mm | 0.50 μm | 15 m | -60 to 330/350°C |
227-36009-02 | 0.32 mm | 0.50 μm | 30 m | -60 to 330/350°C |
227-36009-03 | 0.32 mm | 0.50 μm | 60 m | -60 to 330/350°C |
227-36010-01 | 0.32 mm | 1.00 μm | 30 m | -60 to 330/350°C |
221-75928-60 | 0.32 mm | 1.00 μm | 60 m | -60 to 330/350°C |
227-36011-01 | 0.32 mm | 4.00 μm | 30 m | -60 to 330/350°C |
227-36012-01 | 0.53 mm | 0.50 μm | 15 m | -60 to 330/350°C |
227-36012-02 | 0.53 mm | 0.50 μm | 30 m | -60 to 330/350°C |
227-36013-01 | 0.53 mm | 1.00 μm | 15 m | -60 to 330/350°C |
227-36013-02 | 0.53 mm | 1.00 μm | 30 m | -60 to 330/350°C |
227-36014-01 | 0.53 mm | 1.50 μm | 15 m | -60 to 330/350°C |
227-36014-02 | 0.53 mm | 1.50 μm | 30 m | -60 to 330/350°C |
227-36014-03 | 0.53 mm | 1.50 μm | 60 m | -60 to 330/350°C |
For SH-I-1 MS Columns with Integrated Guard column, please refer to the Integrated Guard Columns' page.
News / Events
-
Shimadzu has released the Shim-pack™ SUR-Na Columns for Ligand Exchange Chromatography.
Shim-pack™ SUR-Na, a ligand exchange chromatography column, offers excellent performance by combining size exclusion mode and sodium-based ligand exchange mode to provide superior separation of sugar components. Pure water can be used for the mobile phase, resulting in less effort to prepare for the analysis.
-
Release of New Shim-pack Septer Series
Shimadzu has release new Shim-pack Scepter Series colmuns…
-
Release of Four New Shim-pack UC Series
Shimadzu has release four new Shim-pack UC Series colmuns…
-
Shimadzu has released the CoreFocus Library.
CoreFocus Library is a digital library where you can find and learn different methods for analyzing your target compounds.
-
Shimadzu New Applications
-
Shimadzu has released the High-speed Organic Acid Analysis Column Shim-pack Fast-OA.
Designed and intended specifically for use under low pH condition, Shim-pack Velox SP (Sterically Protected)-C18 offers a well balanced retention profile with a long life time even under harsh, acidic condition needed for LC/MS(/MS) analysis.