SH-I-5MS

- Low-polarity phase: Crossbond™ 5% diphenyl / 95% dimethyl polysiloxane
- Tested and guaranteed for ultra-low bleed; improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
- General-purpose columns for semi-volatiles, phenols, amines, residual solvents, drugs of abuse, pesticides, PCB congeners (e.g., Aroclor mixes), solvent impurities.
- Equivalent to USP G27 and G36 phases.
- Similar phases: HP-5ms UI, HP-5ms, DB-5, Ultra-2, CP Sil 8 CB, SPB-5, Equity-5
P/N | ID | df (Film Thickness) | Length | Temp. Range |
---|---|---|---|---|
227-36342-01 | 0.10 mm | 0.10 μm | 10 m | -60 to 330/350°C |
227-36015-01 | 0.18 mm | 0.18 μm | 20 m | -60 to 330/350°C |
227-36016-01 | 0.18 mm | 0.30 μm | 20 m | -60 to 330/350°C |
227-36017-01 | 0.18 mm | 0.36 μm | 20 m | -60 to 330/350°C |
227-36018-01 | 0.20 mm | 0.33 μm | 25 m | -60 to 330/350°C |
227-36018-02 | 0.20 mm | 0.33 μm | 50 m | -60 to 330/350°C |
221-75940-15 | 0.25 mm | 0.25 μm | 15 m | -60 to 330/350°C |
221-75940-30 | 0.25 mm | 0.25 μm | 30 m | -60 to 330/350°C |
227-36019-01 | 0.25 mm | 0.25 μm | 60 m | -60 to 330/350°C |
227-36020-01 | 0.25 mm | 0.40 μm | 30 m | -60 to 330/350°C |
227-36021-01 | 0.25 mm | 0.50 μm | 15 m | -60 to 330/350°C |
221-75941-30 | 0.25 mm | 0.50 μm | 30 m | -60 to 330/350°C |
221-75942-60 | 0.25 mm | 0.50 μm | 60 m | -60 to 330/350°C |
227-36022-01 | 0.25 mm | 1.00 μm | 15 m | -60 to 330/350°C |
227-36022-02 | 0.25 mm | 1.00 μm | 30 m | -60 to 330/350°C |
227-36022-03 | 0.25 mm | 1.00 μm | 60 m | -60 to 330/350°C |
227-36023-01 | 0.32 mm | 0.25 μm | 15 m | -60 to 330/350°C |
221-75943-30 | 0.32 mm | 0.25 μm | 30 m | -60 to 330/350°C |
227-36023-02 | 0.32 mm | 0.25 μm | 60 m | -60 to 330/350°C |
227-36024-01 | 0.32 mm | 0.50 μm | 15 m | -60 to 330/350°C |
221-75944-30 | 0.32 mm | 0.50 μm | 30 m | -60 to 330/350°C |
227-36024-02 | 0.32 mm | 0.50 μm | 60 m | -60 to 330/350°C |
227-36025-01 | 0.32 mm | 1.00 μm | 15 m | -60 to 330/350°C |
227-36025-02 | 0.32 mm | 1.00 μm | 30 m | -60 to 330/350°C |
227-36025-03 | 0.32 mm | 1.00 μm | 60 m | -60 to 330/350°C |
227-36026-01 | 0.53 mm | 0.25 μm | 15 m | -60 to 330/350°C |
227-36026-02 | 0.53 mm | 0.25 μm | 30 m | -60 to 330/350°C |
227-36027-01 | 0.53 mm | 0.50 μm | 15 m | -60 to 330/350°C |
227-36027-02 | 0.53 mm | 0.50 μm | 30 m | -60 to 330/350°C |
227-36028-01 | 0.53 mm | 1.00 μm | 15 m | -60 to 330/350°C |
227-36028-02 | 0.53 mm | 1.00 μm | 30 m | -60 to 330/350°C |
227-36029-01 | 0.53 mm | 1.50 μm | 15 m | -60 to 330/350°C |
227-36029-02 | 0.53 mm | 1.50 μm | 30 m | -60 to 330/350°C |
For SH-I-5MS Columns with Integrated Guard column, please refer to the Integrated Guard Columns' page.
News / Events
-
Shimadzu has released the Shim-pack™ SUR-Na Columns for Ligand Exchange Chromatography.
Shim-pack™ SUR-Na, a ligand exchange chromatography column, offers excellent performance by combining size exclusion mode and sodium-based ligand exchange mode to provide superior separation of sugar components. Pure water can be used for the mobile phase, resulting in less effort to prepare for the analysis.
-
Release of New Shim-pack Septer Series
Shimadzu has release new Shim-pack Scepter Series colmuns…
-
Release of Four New Shim-pack UC Series
Shimadzu has release four new Shim-pack UC Series colmuns…
-
Shimadzu has released the CoreFocus Library.
CoreFocus Library is a digital library where you can find and learn different methods for analyzing your target compounds.
-
Shimadzu New Applications
-
Shimadzu has released the High-speed Organic Acid Analysis Column Shim-pack Fast-OA.
Designed and intended specifically for use under low pH condition, Shim-pack Velox SP (Sterically Protected)-C18 offers a well balanced retention profile with a long life time even under harsh, acidic condition needed for LC/MS(/MS) analysis.