SH-PolarD
- Polar phase: Crossbond™ acid-deactivated Carbowax™ polyethylene glycol
- Dedicated columns for free (underivatized) acids, some inorganic acids.
- Resistant to oxidative damage.
- Equivalent to USP G25 and G35 phases.
- Similar phases: HP-FFAP, DB-FFAP, VF-DA, CP-Wax 58 CB, CP-FFAP CB, Nukol
P/N | ID | df (Film Thickness) | Length | Temp. Range |
---|---|---|---|---|
227-36271-01 | 0.25 mm | 0.10 μm | 30 m | 40 to 250/260°C |
221-75981-30 | 0.25 mm | 0.25 μm | 30 m | 40 to 250/260°C |
227-36272-01 | 0.25 mm | 0.25 μm | 60 m | 40 to 250/260°C |
227-36273-01 | 0.25 mm | 0.50 μm | 30 m | 40 to 250/260°C |
227-36273-02 | 0.25 mm | 0.50 μm | 60 m | 40 to 250/260°C |
227-36274-01 | 0.32 mm | 0.10 μm | 30 m | 40 to 250/260°C |
227-36321-02 | 0.32 mm | 0.25 μm | 30 m | 40 to 250/260°C |
227-36275-01 | 0.32 mm | 0.25 μm | 60 m | 40 to 250/260°C |
227-36322-02 | 0.32 mm | 0.50 μm | 30 m | 40 to 250/260°C |
227-36276-01 | 0.32 mm | 0.50 μm | 60 m | 40 to 250/260°C |
227-36277-01 | 0.32 mm | 1.00 μm | 30 m | 40 to 240/250°C |
227-36277-03 | 0.32 mm | 1.00 μm | 50 m | 40 to 240/250°C |
227-36277-02 | 0.32 mm | 1.00 μm | 60 m | 40 to 240/250°C |
227-36278-01 | 0.53 mm | 0.25 μm | 30 m | 40 to 250/260°C |
227-36278-02 | 0.53 mm | 0.25 μm | 60 m | 40 to 250/260°C |
227-36279-01 | 0.53 mm | 0.50 μm | 30 m | 40 to 250/260°C |
227-36279-02 | 0.53 mm | 0.50 μm | 60 m | 40 to 250/260°C |
227-36280-01 | 0.53 mm | 1.00 μm | 30 m | 40 to 240/250°C |
227-36280-02 | 0.53 mm | 1.00 μm | 60 m | 40 to 240/250°C |
227-36281-01 | 0.53 mm | 1.50 μm | 30 m | 40 to 230/240°C |
227-36281-02 | 0.53 mm | 1.50 μm | 60 m | 40 to 230/240°C |
News / Events
-
Shimadzu has released the Shim-pack Mix-HILIC, Chromatography Column for Hydrophilic Interactions
Comprehensive Analysis of Hydrophilic Metabolites in Metabolomics
-
Shimadzu has released the Shim-pack™ SUR-Na Columns for Ligand Exchange Chromatography.
Shim-pack™ SUR-Na, a ligand exchange chromatography column, offers excellent performance by combining size exclusion mode and sodium-based ligand exchange mode to provide superior separation of sugar components. Pure water can be used for the mobile phase, resulting in less effort to prepare for the analysis.
-
Release of New Shim-pack Septer Series
Shimadzu has release new Shim-pack Scepter Series colmuns…
-
Release of Four New Shim-pack UC Series
Shimadzu has release four new Shim-pack UC Series colmuns…
-
Shimadzu has released the CoreFocus Library.
CoreFocus Library is a digital library where you can find and learn different methods for analyzing your target compounds.
-
Shimadzu has released the High-speed Organic Acid Analysis Column Shim-pack Fast-OA.
Designed and intended specifically for use under low pH condition, Shim-pack Velox SP (Sterically Protected)-C18 offers a well balanced retention profile with a long life time even under harsh, acidic condition needed for LC/MS(/MS) analysis.