LC/MS/MS Method Package for Short Chain Fatty Acids
For LabSolutions™ LCMS Software
Short-Chain Fatty Acids and Organic Acids Targeted for Analysis

Of the short-chain fatty acids produced by intestinal bacteria, acetic acid, propionic acid, and butyric acid are well known, and it has been reported that there are some connections between them and lifestyle-related diseases such as obesity and diabetes. Generally speaking, short-chain fatty acids are highly volatile and highly hydrophilic. This makes it difficult to perform LCMS analysis using a conventional reverse phase system. For that reason, this method package targets short-chain fatty acids (C2 to C5) that have been derivatized using 3-nitrophenylhydrazine (3-NPH). After setting MRM transitions, it can be used for the simultaneous analysis (of 22 components), including organic acids related to the central metabolic pathways.
|
|
MRM Transition Settings
When making MRM transition settings, selectivity can be enhanced by specifying characteristic product ions for 3-nitrophenylhydrazine derivatives. Note that some organic acids have a carbonyl group derived from ketones, so 3-nitrophenylhydrazine derivatives that reacted with carboxylic acid and the carbonyl group are targeted for MRM transition.
Pretreatment Protocol Including Derivatization
The entire protocol necessary for pretreatment, including the derivatization step using 3-nitrophenylhydrazine, is contained in the Instruction Manual for this method package. By following these procedures, an analyst should be able to perform the entire process, from derivatization to data acquisition and data analysis, immediately after the package is introduced.
For the derivatization using 3-nitrophenylhydrazine, carbodiimide is used as a condensing agent, and reaction proceeds under mild conditions. Moreover, in order to efficiently carry out reactions with both short-chain fatty acids and organic acids, this method package includes derivatization using 3-NPH instead of the more commonly used 2-NPH. Also, 3-NPH derivatizations after reactions are stable, and quantitative analysis of the short-chain fatty acids or organic acids in the sample can be performed through reaction with an appropriate amount of derivatization reagent. Additionally, as reactions take place in water solutions using this derivatization reagent, the sample will not be dried and volatile components will not be lost.

Derivatization Reaction with 3-nitrophenylhydrazine (3-NPH)
The following example shows an analysis using the LCMS-8060 of a standard mixed solution of short-chain fatty acids/organic acids. An MRM chromatogram of short-chain fatty acids/organic acids derivatized using 3-NPH is shown. As can be seen, sufficient separations of the components, such as the structural isomers butyric acid, isobutyric acid, fumaric acid, maleic acid, citric acid, and isocitric acid were obtained. This method package includes MRM transitions that were formulated beforehand in order to achieve optimization for 3-NPH derivatizations for short-chain fatty acids/organic acids. As a result, short-chain fatty acids (C2 to C5) and organic acids representative of central metabolic pathways, which are difficult to analyze with LCMS using a conventional reversed phase system, can be analyzed simultaneously.

Remarks and Precautions
LabSolutions LCMS Ver. 5.99SP2 or later is required.
LabSolutions is a trademark of Shimadzu Corporation.
News / Events
-
Handbook of Analysis Procedures for EPA method 533, EPA method 537.1 are now available.
The validity of the analysis performed by each laboratory needs to be confirmed by Quality Control (QC). This article section shows the general analytical procedure for fulfilling QC requirements. Note that the procedure could be modified depending on the situation in the lab and analysts.
-
Shimadzu has released the CLAM-2040, Fully Automated Sample Preparation Module for LCMS
The CLAM-2040 accompanies you on most of the analytical workflow and improves your overall throughput by drastically reducing the sample preparation time. Simply place the blood tubes in position and the CLAM-2040 performs the next steps automatically, from sample extraction, up to the LCMS analysis and data processing.
-
Per- and Polyfluoroalkyl Substances (PFAS)
Per-and polyfluoroalkyl substances (PFAS) are a group of persistent and harmful chemicals that can be commonly found in the environment globally. These anthropogenic chemicals can come from various sources such as manufacturing, industrial applications, food contact materials and consumer products, and eventually end up and accumulate in the water, soil and living organisms.
-
Interpretation of LC Chromatograms Facilitated by Mass Detection and the Mass-it™ Function
The LCMS-2050 mass spectrometer includes Mass-it functionality that can overlay compound mass (m/z) information, obtained with the mass spectrometer, onto UV chromatograms to support supplementing qualitative analysis results obtained using a UV detector.
-
Technical Background for the LCMS-2050, a Compact Mass Detector for LC
The LCMS-2050 single quadrupole mass spectrometer is highly compact in size, yet provides both high-speed and high-sensitivity analysis. Shimadzu’s technology has been condensed into an instrument miniaturized to the utmost.
-
Shimadzu has updated LC/MS/MS Method Package for Cell Culture Profiling Ver. 3 for LabSolutions LCMS
Version 3 of this method package adds metabolites characteristic of CHO cells, which are frequently used in the manufacture of monoclonal antibodies. Together with existing analytes, this Method Package enables the analysis of 144 compounds in under 20 minutes per sample.