Useful Functions for Measurement and Analysis

    1
    Preparation for Measurement
     
    ↓
    ↓
    ↓
    Concerned whether the temperature program can be input without errors.

    Temperature Preview Function

    Temperature Preview Function

    You can view the input temperature in real time on the preview screen.

     

     

     
    Want to keep the product at the preset temperature.

    Configure the Temperature During Standby

    Configure the Temperature During Standby

    After configuring the hold temperature, the instrument will standby at the configured temperature.

     

     

     
    2 
    Start Measurement
     
    ↓
    ↓
    ↓
    Time it takes to name a file after a measurement.

    Automatic File Naming Function

    Automatic File Naming Function

    LabSolutions TA enables automatic file naming when starting a measurement.
    Settings are free to be changed.

     
    Want to increase the temperature immediately after starting a measurement.

    Start Temperature Function

    Start Temperature Function

    If a start temperature has been configured, as soon as a measurement begins, the temperature will quickly increase or decrease to the specified value. After this, the temperature will be increased or decreased in accordance with the prescribed temperature program.

    Note: This cannot be used with the 50 series.

     

     

     
    3
    During Measurement
     
    ↓
    ↓
    ↓
    Want to analyze the data in the middle of a measurement.

    Saving Snapfile

    Saving Snapfile

    LabSolutions TA allows saving data during a measurement for analysis.

    Measurement Completed  
    4
    File Open
     
    ↓
    ↓
    ↓
    Want to compare different measurements.

    Overwriting Files Function

    Overwriting Files Function

    Measurement data can be displayed all at once.
    Additional data can also be displayed.
    Even measurement data from different products can be displayed.

    5
    Analysis
     
    ↓
    ↓
    ↓
    It takes time and effort to analyze multiple data files individually.

    Simultaneous Analysis of Multiple Data Files

    Simultaneous Analysis of Multiple Data Files

    Multiple data files can be analyzed simultaneously.

     
    Want to analyze and compare high and low temperatures easily.

    Setting Analysis Range

    Setting Analysis Range

    The data of high and low temperatures can be easily divided for analysis and comparison.

     
    6
    Report Creation
     
    ↓
    ↓
    ↓
    Want to create a clear and easy-to-understand report.

    Report Display Function

    Report Display Function

    The data is editable in the print layout.

     
    Running the same analysis repeatedly to create a report is time consuming and labor intensive.

    Automatic Manipulation and Automatic Analysis Functions (Template Function)

    Automatic Manipulation and Automatic Analysis Functions (Template Function)

    The same analysis and correction performed in template files can be automated.
    Templates can be set before or after a measurement.

    Go to the Next Measurement  

    Videos

    Related applications