User Benefits Application News Table 1 Analytical Conditions and Target Compounds Introduction In the quality control of pharmaceuticals and foods with functional claims, verifying the content of active ingredients and detecting impurities are essential to ensure product efficacy and safety. These tasks are typically performed by qualitative and quantitative analysis using liquid chromatography (LC). However, the large number of chromatograms generated must be reviewed to identify peaks based on retention time, compare quantitative results with specification limits, and confirm the presence or absence of impurities. When these processes are performed manually, they are susceptible to human error and the risk of overlooking important findings. LabSolutions Detect automatically analyzes the differences between a reference chromatogram representing the impurity-free product and target chromatograms obtained during routine quality control, thereby preventing missed changes in active ingredient content and overlooked impurity contamination. Application News No. 01- 01014 -EN introduced a case study in which LabSolutions Detect was applied to the LC analysis of pramipexole hydrochloride, as described in the USP, using the LC-2070C (UV model) to improve the efficiency of quality control operations. In this article, a method for further reducing the risk of missing impurities by combining LabSolutions Detect with the LC-2070C 3D (PDA model) and utilizing multi-wavelength information is presented. LabSolutions Detect enhances the reliability and productivity of quality control operations by reducing the risk of human error and oversight associated with visual inspection. The use of a photodiode array (PDA) detector enables comprehensive detection across multiple wavelengths, further reducing the risk of missing impurities. Streamlining Quality Control Operations with LabSolutions Detect—Reducing the Risk of Missing Impurities with PDA Detector Anomaly Peak Detection Support Software Ultra High Performance Liquid Chromatograph Shinichi Fujisaki System : LC-2070C 3D Control : Antipyrine and Probenecid Sample : Control with added Salicylic acid Mobile phase Pump A : 0.1% formic acid in water Pump B : Acetonitrile Column : Shim-pack Scepter C18-120 *1 (150 mm × 4.6 mm I.D., 5 µm) Injection Vol. : 5 µL B Conc. : 20%(0 min)→95%(5-6 min)→20%(6-12 min) Column Temp. : 40 ˚C Flow rate : 1 mL/min Detection : 261 nm *1 P/N : 227-31020-05 Analytical Conditions and Target Compounds Comprehensive Impurity Detection Using a PDA Detector By utilizing multi-wavelength data acquired with a photodiode array (PDA) detector, LabSolutions Detect enables comprehensive impurity detection. In addition, impurity peaks are automatically detected according to user-defined acceptance criteria. In this article, the upper and lower acceptance limits for the height of unknown impurity peaks relative to the reference data were set to 10 mAU, and the target wavelength range was set to 190–400 nm (Fig. 1). Under these conditions, impurity detection was performed on the target data. Fig. 1 Target Wavelength Range (Upper) Acceptance Criteria for Unknown Impurity Detection (Lower) The chromatograms obtained at a detection wavelength of 261 nm is shown in Fig. 2. For both the control (reference data) and the sample (target data), only two compounds, Antipyrine and Probenecid, were detected. Consequently, no unknown impurities were detected in the target data when analysis was performed at the single detection wavelength of 261 nm. However, single-wavelength analysis carries the risk of overlooking impurities that absorb outside the selected wavelength. The contour display of PDA chromatograms obtained from the multi-wavelength analysis of the sample (target data) is shown in Fig. 3 (upper), where the vertical axis represents the detection wavelength and the horizontal axis represents the retention time. If a peak that deviates from the specified criteria is detected, it is highlighted in red on the contour display (red circle in the figure). The extracted chromatogram obtained at a detection wavelength of 261 nm and 303 nm is shown in Fig. 3 (lower). Although only Antipyrine and Probenecid were detected at 261 nm, Salicylic acid was detected as an unknown impurity at a detection wavelength of 303 nm (red circle in the figure). These results demonstrate that the use of a PDA detector enables comprehensive impurity detection across a wide wavelength range, thereby reducing the risk of overlooking impurities. Fig. 2 Chromatograms Obtained at a Detection Wavelength of 261 nm Antipyrine Probenecid Control (Reference) Sample (Target) Detection: 261 nm The samples and analytical conditions are summarized in Table 1. An impurity-free control sample was used as the reference data, while a control sample spiked with salicylic acid was used as the target data.
Application News www.shimadzu.com/an/ Shimadzu Corporation © Shimadzu Corporation, 2026 For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. See https://www.shimadzu.com/about/trademarks/index.html for details. Third party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “”. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. First Edition: Sep. 2026 01-01294-EN LabSolutions and Shim-pack Scepter are trademarks of Shimadzu Corporation or its affiliated companies in Japan and/or other countries. Conclusion Ensuring product efficacy and safety is a fundamental requirement in quality control operations. LabSolutions Detect automatically analyzes the differences between the reference data and the target data, thereby automating the detection of unknown impurities. Furthermore, when combined with a photodiode array (PDA) detector, multi-wavelength data can be acquired simultaneously in a single analysis, further reducing the risk of overlooking impurities. As a result, quality control operations can be performed more efficiently while maintaining high product quality and ensuring regulatory compliance. Fig. 3 Impurity Detection Using LabSolutions Detect The contour display of PDA chromatograms (upper) and extracted chromatograms (lower). Antipyrine Probenecid Salicylic acid Detection: 303 nm Detection: 261 nm * y-axis scales are adjusted for comparison Detection: 303 nm Detection: 261 nm Antipyrine Probenecid Salicylic acid
Please fill out the survey Related Products Some products may be updated to newer models. i-Series High Performance Liquid Chromatograph LabSolutions Detect Anomaly Detection Support Software Related Solutions Pharmaceutical and Biopharmaceutical Small Molecule Pharmaceutical Price Inquiry Product Inquiry Technical Service / Support Inquiry Other Inquiry Powered by TCPDF (www.tcpdf.org)