User Benefits Application News Fig. 1 ETFE-Coated Wire Sample Materials ETFE-coated wire Introduction As regulations on PFAS and halogenated organic flame retardants tighten in the EU 1), 2) and some U.S. states 3), 4) , there is a growing need to identify at an early stage whether halogens such as fluorine are present in electrical and electronic materials. Rapid supply-chain screening is also increasingly required. The energy dispersive X-ray fluorescence spectrometer EDX-8100 requires little to no sample preparation and can quickly and easily detect halogens such as fluorine (F), chlorine (Cl), and bromine (Br). EDX-8100 quickly shows whether these halogens are present, helping narrow down regulated products and prioritize samples for detailed analysis. This article demonstrates the usefulness of halogen detection by EDXRF using an ETFE-coated wire and a relay as examples. 1), 2) In the electronics and semiconductor sectors under PFAS regulations, polymeric PFAS such as PTFE are also under consideration, with measures including a 13.5-year derogation period after entry into force (as of May 2026). 3), 4) Under the Washington Administrative Code regarding organic flame retardants, intentional addition is assumed for plastic external housings of electrical and electronic products when the total bromine, total chlorine, and total fluorine content exceeds 1000 ppm. Related screening analysis by X-ray fluorescence spectrometry is also referenced. EDXRF analyzes halogens (F, Cl, Br, and I) more easily than absorption/emission methods. Fluorine (F) on the material surface is detected directly, without sample preparation. Simultaneous halogen analysis enables simple screening for the possible use of halogenated flame retardants. Analysis of Fluorine by EDXRF —A Simple Check for PFAS in Electrical and Electronic Components Yu Kubota, Hideki Nakamura Energy Dispersive X-ray Fluorescence Spectrometer EDX-8100 Table 1 Quantitative Analysis Results for ETFE-Coated Wire (For Reference Only) [wt%] Fig. 2 Qualitative Analysis Results for ETFE-Coated Wire F Cl 1. Wire-Coating Resin Sample Preparation The sample was measured directly in the bundled state. Fig. 1 shows an image of the sample taken with the instrument’s built-in sample observation camera. Qualitative/Quantitative Analysis Fig. 2 and Table 1 show the qualitative and quantitative results. Fluorine, the main constituent of ETFE (ethylene tetrafluoroethylene), was strongly detected. By the FP method, the material ETFE was quantified assuming a composition of C 4 H 4 F 4 . Since wire components such as Cu and Sn were also detected, values should be treated as reference values for a composite product. Sample C4H4F4 Cl Cu *1 Co Al Sn *1 Si ETFE-coated wire 95.01 0.13 4.59 0.12 0.096 0.053 0.009 *1 Cu and Sn are presumed to be components of the wire.
Application News www.shimadzu.com/an/ Shimadzu Corporation © Shimadzu Corporation, 2026 For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. See https://www.shimadzu.com/about/trademarks/index.html for details. Third party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “”. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. First Edition: Aug. 2026 01-00977-EN Conclusion As shown above, fluorine can be detected and quantified rapidly and easily when its content is about 0.1 wt% or higher. In addition to intentional use, the presence of fluorine compounds can also be confirmed in cases of unintentional inclusion, such as transfer or contamination. In the electrical and electronics field, demand for analysis related to PFAS and halogenated flame retardants is expected to increase in the future, and EDXRF is useful as a simple initial screening method. * Here, PFAS denotes organofluorine compounds. Note that EDXRF cannot identify the compound type. * For regulatory details, please refer to the latest official publications. This article focuses only on analytical considerations. References 1) European Chemicals Agency (ECHA), “Submitted restrictions under consideration,” ECHA. 2) ECHA PACT RAC sector evaluation: Electronics and Semiconductors . 3) Washington State Legislature, “Chapter 173-337 WAC: Safer Products Restrictions and Reporting,” Washington Administrative Code. 4) Washington State Department of Ecology, “Resource for Complying with the Safer Products for Washington Rule: Electric and Electronic Products.” Related Applications 1. Analysis of Fluorine by EDXRF: Simple Check for Use of PFAS for Textile and Kitchen Supplies, Application News No. 01- 00975-EN Fig. 3 Relay Fig. 4 Qualitative Analysis Results for Relay Table 2 Quantitative Analysis Results for Relay (For Reference Only) [wt%] Table 3 Analytical Conditions 2. Electrical Component Sample Materials Relay Fig. 3 shows an image of the sample. Sample Preparation The sample was measured directly. Qualitative/Quantitative Analysis Fig. 4 and Table 2 show the qualitative and quantitative results. On the relay surface, F, Br, and Sb were detected, suggesting the possible presence of fluorine-containing materials (release agents, coatings, anti-dripping agents, etc.), brominated flame retardants, and flame-retardant synergists. Other elements such as Cu and Fe, likely derived from internal components of the relay, were also detected, so values should be treated as reference values for a composite product. Analytical Conditions Table 3 lists the analytical conditions used for the ETFE-coated wire and relay. For measuring F, the C-Sc channel integration time is as short as 60 seconds, enabling rapid measurement. Measurement channel Ti-U C-Sc S-Ca Analysis line Kα, Kβ, Lα, Lβ, ... X-ray tube Rh target Tube voltage 50 kV 15 kV Tube current Automatic control Collimator 10 mm φ Integration time 20 s 60 s 20 s Dead time Max. 30 % Filter None #2 Detector SDD semiconductor detector Atmosphere Vacuum Quantitative analysis method FP method *1 The organic fraction was quantified by setting C 12 H 12 O 4 as the balance (residual amount). Br F Sb Sample F Br Sb Ca Si Cu Sr Fe Pb Ni Zn C12H12O4 *1 Relay 0.35 1.93 1.23 1.63 1.21 0.31 0.017 0.014 0.008 0.006 0.005 93.29
Please fill out the survey Related Products Some products may be updated to newer models. EDX-8100 Energy Dispersive X-ray Fluorescence Spectrometer Related Solutions Electronics Electronic Component Price Inquiry Product Inquiry Technical Service / Support Inquiry Other Inquiry Powered by TCPDF (www.tcpdf.org)