Content overflows the browser. Try zooming out (Ctrl + −) to see the full page. PDF Download
User Benefits Application News Fig. 1 Chromatogram of mixed standard solution at 1 mg/L of chloride and sulfate ions Table 1 shows the analytical conditions, and Fig. 1 shows the resulting chromatogram of mixed standard solution of chloride and sulfate ions. The instrument used was a Nexera IC suppressor-type ion chromatograph. Linearity Table 1 Analytical conditions Table 2 Calibration levels and coefficients of determination (r 2 ) First-generation bioethanol produced from raw materials such as corn and sugarcane has been utilized to achieve carbon neutrality. However, research and development for second-generation bioethanol produced from non-food, cellulose-based raw materials is also underway to avoid competition with food crops. In Japan, eight companies, including Toyota Motor Corporation, have formed the “Research Association of Biomass Innovation for Next Generation Automobile Fuels” (raBit) to advance research on next-generation bioethanol technologies. Shimadzu participates as a supporting member and promotes research and development through analytical technology cooperation. It is known that the presence of chloride and sulfate ions in fuel ethanol can form engine residue, leading to reduced engine performance. ASTM D4806-25 2) specifies fuel ethanol quality as criterion of chloride ion must not exceed 6.7 mg/kg and that of sulfate ion must not exceed 4 mg/kg. ASTM D7319-22 includes test methods for chloride and sulfate ions in fuel ethanol using ion chromatography. In this application, we present an example of the analysis of chloride and sulfate ions in bioethanol using the Nexera IC in accordance with ASTM D7319-22. Introduction Analysis of chloride and sulfate ions in fuel ethanol can be conducted in accordance with ASTM D7319-22 1) . Accurate quantitative determination, exhibiting excellent linearity and repeatability, can be achieved at concentration levels significantly below the limits specified by the ASTM criteria. Analysis of Chloride and Sulfate Ions in Bioethanol Using the Nexera IC Ion Chromatograph Tomoka Kaseda Ion Chromatograph Nexera IC System : Nexera IC Column : Shim-pack IC-SA2 *1 (250 mm×4.0 mm I.D., 9 µm) Guard Column : Shim-pack IC-SA28(G) *2 (10 mm × 4.6 mm I.D., 9 µm) Mobile Phase : 1.8 mmol/L sodium carbonate 1.7 mmol/L sodium hydrogen carbonate Flow Rate : 1.0 mL/min Column Temp. : 30 ˚C Injection Volume : 5 µL Vial : Shimadzu Vial, LC, 4 mL Polypropylene *3 Detection : Conductivity Analysis of mixed standard solution A calibration curve was created using seven calibration levels for chloride ion and six for sulfate ion within the concentration ranges specified in ASTM D7319-22. Table 2 shows the respective calibration levels and coefficients of determination (r²) for chloride and sulfate ions. It was confirmed that the r² values of the calibration curves for both ions were 0.99 or more, as specified in ASTM D7319-22. Pretreatment ASTM D7319-22 states that samples can be analyzed without any pretreatment for chloride and sulfate ions in fuel ethanol. However, a pretreatment of the addition of hydrogen peroxide is required to analyze sulfur compounds (potential inorganic sulfate) that are oxidized to sulfate ions in the presence of the oxidant. The pretreatment method is shown in Fig. 2, and the notation of ion species in accordance with ASTM D7319-22 is shown in Table 3. µS/cm 0.0 5.0 10.0 min -0.10 0.00 0.10 0.20 0.30 15.0 Cl SO 4 ions Calibration levels (mg/L) Coefficients of determination (r 2 ) Cl 0.3, 0.5, 1, 5, 10, 20, 50 ≥ 0.999 SO4 0.3, 0.5, 1, 5, 10, 20 ≥ 0.999 Sample 9.5 mL Inject into the Ion chromatograph 30% Hydrogen peroxide 0.5 mL Ion species Description Pretreatment Total inorganic chloride Chloride ion without pretreatment None Total inorganic sulfate Sulfate ion without pretreatment Potential inorganic sulfate Sulfate ion with oxidant Addition of hydrogen peroxide Fig. 2 Pretreatment procedure (For potential inorganic sulfate measurement) Table 3 Notation of ion species in accordance with ASTM D7319-22 Analysis of bioethanol samples and spike and recovery test Fig. 3 shows the analytical results for bioethanol sample and standard-spiked bioethanol sample, to which a mixed standard solution of chloride and sulfate ions was spiked to make concentration of 1 mg/L for each in the sample solution. The concentrations and recovery rates obtained for the spiked sample are shown in Table 4. Calibration curves for quantitative determination were prepared for both chloride and sulfate ions using six levels less than 20 mg/L as shown in Table 2 to consider the quantitative accuracy in the low-concentration range. *1 P/N: 228-38983-91 *2 P/N: 228-38983-92 *3 P/N: 228-31537-91
Application News www.shimadzu.com/an/ Shimadzu Corporation © Shimadzu Corporation, 2026 For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. See https://www.shimadzu.com/about/trademarks/index.html for details. Third party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “”. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. First Edition: Aug. 2026 01-01211-EN Conclusion Nexera and Shim-pack are trademarks of Shimadzu Corporation or its affiliated companies in Japan and/or other countries. Chloride and sulfate ions in bioethanol were determined using a Nexera IC system in accordance with ASTM D7319-22. The method offers high sensitivity, linearity, and repeatability, enabling reliable quantification at concentrations well below ASTM-specified limits, thus supporting effective quality control and regulatory compliance of fuel ethanol. <References> 1) ASTM D7319-22, Standard Test Method for Determination of Total and Potential Sulfate and Inorganic Chloride in Fuel Ethanol by Direct Injection Suppressed Ion Chromatography, ASTM International, West Conshohocken, PA, 2007, www.astm.org 2) ASTM D4806-25a, Standard Specification for Denatured Fuel Ethanol for Blending with Gasolines for Use as Automotive Spark-Ignition Engine Fuel, ASTM International, West Conshohocken, PA, 2008, www.astm.org <Related Applications> 1. Determination of Organic Impurities in Bioethanol Using JIS K2190 Application News No. 01-01074-EN 2. Determination of Elemental Impurities in Bioethanol Using ICP-MS Application News No.01-01021-EN 3. Monitoring of Organic Acids in Biomass Fermentation Process and Yeast Cultivation Process Application News No. eL588 Fig. 6 Result of six consecutive analyses of standard spiked bioethanol with the oxidant Ion species Conc. (mg/L) Content *4 (mg/kg) Recovery (%) Total inorganic chloride 1.05 1.33 105 Total inorganic sulfate 0.71 0.90 71 Cl 0.0 5.0 10.0 15.0 min -0.5 0 0.5 1.0 µS/cm SO 4 (a) Standard spiked bioethanol (b) Bioethanol (a) (b) Repeatability in standard spiked sample The sample and the standard spiked sample, which were treated with hydrogen peroxide solution to measure sulfate ion (potential inorganic sulfate) in the presence of the oxidant, were analyzed. The analytical results are shown in Fig. 4, and the concentration and recovery rate obtained are shown in Table 5. The addition of the oxidant resulted in better recovery rate for sulfate ion compared to that of the sample without pretreatment. This would be due to unstable dissociation condition of sulfate ion in organic solvent and/or denaturation. Ion species Conc. (mg/L) Content *5 (mg/kg) Recovery (%) Potential inorganic sulfate 1.01 1.35 95.8 0.0 5.0 10.0 15.0 min -0.5 0 0.5 1.0 Cl SO 4 (a) Standard spiked bioethanol with the oxidant (b) Bioethanol with the oxidant µS/cm (a) (b) Ion species Retention time (%RSD) Area (%RSD) Pretreatment Total inorganic chloride 0.02 0.51 None Total inorganic sulfate 0.02 5.56 None Potential inorganic sulfate 0.04 0.77 Addition of hydrogen peroxide 0.0 5.0 10.0 15.0 min 0 1.0 2.0 Cl SO 4 µS/cm 0 1.0 2.0 3.0 0.0 5.0 10.0 15.0 min 0 Cl SO 4 µS/cm The repeatability of each spiked sample was evaluated using the relative standard deviation (% RSD). Fig. 5 shows the results of six consecutive analyses of spiked bioethanol, and Fig. 6 shows the results of six consecutive analyses of spiked bioethanol with the oxidant. Furthermore, Table 6 shows the retention time and peak area repeatabilities for the six consecutive analyses. The addition of the oxidant improved the repeatability of sulfate ions, as observed in the spike and recovery test. <Acknowledgements> We would like to express our sincere gratitude to raBit (Research Association of biomass Innovation for Next Generation Automobile Fuels) for providing the samples and assisting with the interpretation of the analytical results. Fig. 3 Comparison of chromatograms of bioethanol and standard spiked bioethanol (without pretreatment) *4 Gravity 0.79 for bioethanol was employed for the conversion of unit from mg/L to mg/kg Table 4 Result of spike and recovery test Fig. 4 Comparison of chromatograms for bioethanol and standard spiked bioethanol (with the oxidant) Table 5 Result of spike and recovery test with the oxidant *5 Gravity 0.79 for bioethanol was employed for the conversion of unit from mg/L to mg/kg Fig. 5 Result of six consecutive analyses of standard spiked bioethanol Table 6 Retention time and peak area repeatabilities for six consecutive analyses of standard spiked bioethanol
Please fill out the survey Related Products Some products may be updated to newer models. Nexera IC Ion Chromatograph Ion Chromatograph Related Solutions Biomass Fuels Clean Energy Price Inquiry Product Inquiry Technical Service / Support Inquiry Other Inquiry Powered by TCPDF (www.tcpdf.org)