Content overflows the browser. Try zooming out (Ctrl + −) to see the full page. PDF Download
User Benefits Application News Fig. 1 SPM-9700HT Plus Samples and Measurement Conditions SSRM Measurement of n-Type Si Sample The n-type Si sample has a stepwise doping concentration profile extending from the surface into the bulk. As pretreatment, the sample was cross-sectioned as shown in Fig. 3, and conduction between the sample holder and the sample was ensured with conductive paint. Table 1 shows the measurement conditions. Visualizing Local Resistance Distributions in an n- Type Si Sample and a Liquid Lithium-Ion Battery Positive Electrode Using SSRM Eiji Iida, Keita Fujino, Yuichiro Ikeda Scanning Probe Microscope/Atomic Force Microscope Instrument: Scanning Probe Microscope SPM-9700HT Plus Scanner: Wide Range scanner (XY: 125 µm, Z: 7 µm) Mode: Spreading-Resistance (SSRM) mode Field of View: 30 µm × 30 µm Applied Voltage: +10.0 V Table 2 Measurement Conditions Measurement Instrument An SPM-9700HT Plus was used for the measurements (Fig. 1). An SPM scans the sample surface with a fine probe to measure the three-dimensional topography and local physical properties of the sample at high magnification. In SSRM, a bias voltage is applied to the sample while a conductive probe scans its surface, as shown in Fig. 2. By measuring the current flowing between the probe and the sample with a logarithmic amplifier, the current and resistance distributions can be visualized over a wider range than is possible in conventional current mode. Fig. 4 Schematic Diagram of Liquid LIB Positive Electrode (a) Overall View, (b) Side View V DC Sample Conductive probe Log amplifier Sample holder Carbon tape Liquid LIB positive electrode Embedding resin (a) (b) SSRM Measurement of Liquid LIB Positive Electrode The liquid LIB positive electrode consists of a positive electrode active material (ternary NCM) and a conductive additive. As pretreatment, the sample was embedded in resin (Fig. 4), and the measurement surface was mechanically polished. Electrical contact between the sample holder and the observation surface was established using carbon tape. Table 2 shows the measurement conditions. Instrument: Scanning Probe Microscope SPM-9700HT Plus Scanner: Wide Range scanner (XY: 125 µm, Z: 7 µm) Mode: Spreading-Resistance (SSRM) mode Field of View: 30 µm × 10 µm Applied Voltage: +6.0 V Table 1 Measurement Conditions Fig. 3 Schematic Diagram of n-Type Si Sample Conductive paint n-type Si sample Sample holder Cross-sectioned area L5 L4 L3 L2 L1 Fig. 5 SSRM Measurement Result of n-Type Si Sample: Resistance Image SSRM Measurement of n-Type Si Sample Fig. 5 shows the SSRM resistance image of the n-type Si sample, and Table 3 shows the in-plane median resistance and carrier concentration in regions L1 to L5. The resistance display range is 10 3 to 10 12 Ω. Resistance increases stepwise from right to left across the field of view, corresponding to changes in carrier concentration. Table 3 Resistance and Carrier Concentration in Each Region L1 L2 L3 L4 L5 In-plane median resistance [Ω] 2.95 ×10 8 1.66 ×10 8 1.26 ×10 5 4.26 ×10 4 2.63 ×10 4 Carrier concentration [atoms/cm 3 ] 1) 5.0 ×10 14 5.0 ×10 15 1.0 ×10 17 1.0 ×10 18 2.0 ×10 19 Introduction In semiconductor devices and liquid lithium-ion batteries (LIBs), the microscopic distribution of components affects device and battery characteristics, so understanding the resistance distribution inside the device at the nanoscale is important. Scanning spreading resistance microscopy (SSRM), a scanning probe microscopy (SPM) technique performed using an atomic force microscope (AFM), maps the resistance distribution in microscopic areas of a sample, making it effective for estimating the dopant concentration in semiconductor devices and visualizing electron conduction paths inside LIBs. This Application News introduces examples of evaluating an n-type Si sample and a liquid LIB positive electrode using SSRM. Current distribution (1 pA to 10 mA) and resistance distribution (0.1 Ω to 10 TΩ) in electronic materials such as semiconductors and batteries can be detected over a wide range. Carrier concentration distributions in semiconductor devices can be estimated from resistance distributions. Distributions of active material and conductive additives, as well as electron conduction paths, in lithium-ion battery electrodes can be estimated from resistance distributions. Fig. 2 Schematic Diagram of SSRM
Application News www.shimadzu.com/an/ Shimadzu Corporation © Shimadzu Corporation, 2026 For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country. The content of this publication shall not be reproduced, altered or sold for any commercial purpose without the written approval of Shimadzu. See https://www.shimadzu.com/about/trademarks/index.html for details. Third party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “”. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. The information contained herein is provided to you "as is" without warranty of any kind including without limitation warranties as to its accuracy or completeness. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. This publication is based upon the information available to Shimadzu on or before the date of publication, and subject to change without notice. First Edition: Oct. 2026 01-01280-EN Conclusion SSRM measurements enabled the visualization of local resistance distributions in an n-type Si sample and a liquid LIB positive electrode. Because SSRM provides current and resistance distribution information over a wide range, something not achievable with conventional current measurements, the method is expected to be further used for improving the performance of semiconductors and batteries. References 1) N. Duhayon et al., “Assessing the performance of two- dimensional dopant profiling techniques”, JVSTB 22, 385 (2004). Acknowledgement We are deeply grateful to Hiroshi Itoh of the National Institute of Advanced Industrial Science and Technology (AIST) for providing the n-type Si sample and for his guidance on the evaluation. SSRM Measurement of Liquid LIB Positive Electrode Fig. 6 shows the SSRM measurement results of the liquid LIB positive electrode. The display ranges are 10 -4 to 10 -10 A for current and 10 5 to 10 11 Ω for resistance. In the topographic image (a), the fine particle shapes of the active material and its surroundings are observed. In the current image (b) and resistance image (c), the current and resistance values differ among active material particles. Focusing on active material particles (1) to (3) outlined in white, the median resistance values are (1) 4.57 × 10 8 Ω, (2) 3.89 × 10 9 Ω, and (3) 1.26 × 10 10 Ω. The high-resistance particle (3) may be electrically isolated by cracks inside the particle or by gaps between the particle and its surroundings. Uneven resistance is also observed within the same particle. Furthermore, in the resistance image, the black regions of particularly low resistance are thought to be the conductive additive, while the bright yellow regions of particularly high resistance are thought to be the embedding resin. In the current image (d), displayed over a range equivalent to the conventional current-mode detection range, the current saturates in both the conductive additive and the active material, making it impossible to distinguish conductivity differences. SSRM effectively detects small current changes within large current variations, as shown by this sample. Fig. 6 SSRM Measurement Results of Liquid LIB Positive Electrode (a) Topographic image, (b) Current image, (c) Resistance image, (d) Current image displayed in a range equivalent to the current detection range of the conventional current mode (e) 3D overlay of topographic and current images, (f) 3D overlay of topographic and resistance images (a) (b) (c) (f) (1) (3) (2) (e) XY: 30 µm Z: 1 µm (d) XY: 30 µm Z: 1 µm Related Applications 1. Analysis of Positive Electrode (NCM) for Lithium Ion Battery by EPMA and SPM, Application News No. P 117 (1) (3) (2) (1) (3) (2) SPM-9700HT is a trademark of Shimadzu Corporation and its affiliated companies in Japan and/or other countries.
Please fill out the survey Related Products Some products may be updated to newer models. SPM-9700HT Plus Scanning Probe Microscope/Atomic Force Microscope Related Solutions Electronics Semiconductor Clean Energy Lithium-ion Battery Price Inquiry Product Inquiry Technical Service / Support Inquiry Other Inquiry