Shimadzu LC Driver for Chromeleon™ 7 - Specs
Seamless control of Shimadzu LC
Product
| Description |
|---|
| Shimadzu LC Driver for Chromeleon™ 7 (for 1 system) |
Compatible ROM Versions
Shimadzu LC Driver Ver. 4.00 Compatible with Chromeleon™ 7 supports the units with the following ROM versions. Update the ROM if necessary.
1) Nexera/Prominence
| Unit | Model | Minimum required ROM version |
|---|---|---|
| System Controller | CBM-20A, CBM-20Alite | 3.70 |
| Pump | LC-30AD | 3.21 |
| LC-20ADXR | 2.12 | |
| LC-20AD | 2.11 | |
| LC-20AT | 2.01 | |
| LC-20Ai | 1.01 | |
| LC-20AB | 2.02 | |
| Column Oven | CTO-30AS | 3.10 |
| CTO-30A | 3.11 | |
| CTO-20A / CTO-20AC | 2.10 | |
| Autosampler | SIL-30ACMP | 3.21 |
| SIL-30AC | 3.22 | |
| SIL-20A (HT, UFLC), SIL-20AC (HT, UFLC), SIL-20AXR, SIL-20ACXR |
Old board: 1.31 New board: 2.12 |
|
| Rack Changer II | 2.00 | |
| Rack Changer, Rack Changer C | 1.11 | |
| Subcontroller | Subcontroller VP (Option Box VP) | 5.22 |
| Detector | SPD-M30A | 4.04 |
| SPD-M20A | 2.03 | |
| SPD-20A, SPD-20AV | Old board: 2.03 New board: 3.03 |
|
| RF-20A, RF-20AXS | 2.02 | |
| RID-20A | Old board: 1.04 New board: 2.04 |
|
| Analog input board (PC-55N) | - |
Note: For Chromeleon 7 compatible Shimadzu LC driver Ver. 2.01 and later, authentication setting on the instrument is required during the installation of the driver. Check the compatible ROM versions of the CBM- 20A/lite and configure settings for the instrument connection key.
2) i-Series (for LC-2030/2040/2030 Plus/2040 Plus)
| Unit | Model | Minimum required ROM version |
|---|---|---|
| i-Series | LC-2030, LC-2030C, LC-2030C 3D LC-2040C, LC-2040C 3D LC-2030C LT LC-2040C MT, LC-2040C 3D MT |
2.30 |
| i-Series Plus | LC-2030 Plus, LC-2030C Plus, LC-2030C 3D Plus LC-2040C Plus, LC-2040C 3D Plus LC-2030C LT Plus LC-2040C MT Plus, LC-2040C 3D MT Plus |
3.02 |
| External Detector | RF-20A, RF-20AXS | 2.02 |
| RID-20A | Old board: 1.04 New board: 2.04 |
Note: For Chromeleon 7 compatible Shimadzu LC driver Ver. 2.01 and later, authentication setting on the instrument is required during the installation of the driver. Check the compatible ROM versions of the i-Series and configure settings for the instrument connection key.
3) i-Series LC-2050/LC-2060
| Unit | Model | Minimum required ROM version |
|---|---|---|
| i-Series LC-2050/LC-2060 |
LC-2050, LC-2050C, LC-2050C 3D LC-2050C LT LC-2060C, LC-2060C 3D LC-2060C 3D MT |
Old board: 3.20 New board: 5.00 *1 |
| Mobile Phase Monitor | MPM-40 | 1.04 |
| External Detector | SPD-M40 *2 | 2.01 |
| RF-20A, RF-20AXS | 2.02 | |
| RID-20A | Old board: 1.04 New board: 2.04 |
Note: i-Series LC-2050/LC-2060 driver does not need the instrument connection key.
- Please use the old board for the LC-2050C LT and LC-2060C 3D MT, not the new board.
- SPD-M40 detector cannot be controlled with LC-2050C 3D, LC-2060C 3D or LC-2060C 3D MT.
4) Nexera series
| Unit | Model | Minimum required ROM version |
|---|---|---|
| System Controller | SCL-40, CBM-40, CBM-40lite | 1.64 *1 |
| Pump | LC-40D, LC-40D XR, LC-40B XR LC-40D XS, LC-40D X3, LC-40B X3 |
|
| 1.02 | ||
| LC-40D XSi | 1.07 | |
| LC-40i | 1.00 | |
| LC-20AB | 2.02 | |
| Column Oven | CTO-40C, CTO-40S | |
| 1.00 | ||
| CTO-30A | 3.11 | |
| Chemical reaction box | CRB-40 | 2.00 |
| Autosampler | ||
| SIL-20A, SIL-20AC | Old board: 1.32 New board: 2.13 |
|
| SIL-30ACMP | 3.21 | |
| SIL-40, SIL-40C, SIL-40 XR, SIL-40C XR SIL-40C XS, SIL-40C X3 |
1.05 *2 | |
| SIL-40C XSi | 1.10 *2 | |
| Plate Changer | 1.04 *2 | |
| Detector | SPD-40, SPD-40V | 2.03 *3 |
| SPD-M40 | 2.01 | |
| SPD-M30A | 4.04 | |
| RF-20A, RF-20AXS | 2.02 | |
| CDD-10Avp | 5.10 | |
| RID-20A | Old board: 1.04 New board: 2.04 |
|
| Optional board | - | |
| Mobile Phase Monitor | MPM-40 | 1.02 |
| Mobile Phase Flow Line Switching Valve |
LPGE Unit, FCV-11AL, FCV-11ALS UV recycle valve |
- |
| High-Pressure Flow Line Switching Valve |
FCV-0206, FCV-0607, FCV-0206H FCV-0607H, FCV-0206H3, FCV-0607H3, FCV-0206H2i, FCV-0607H2i, FCV-12AHi, FCV-14AHi, FCV-36AH |
- |
| FCV-BOX, FCV-S | - | |
| FCV-DR | 1.02 |
- To resolve the problem Regarding SPD-40/40V Response Setting (Fast/Standard/Slow) under Other Vendors’ LC Drivers, update the ROM version of the system controller to Ver. 1.64 or later.
- When updated ROM version of Autosampler to 1.08 or later, please update the ROM version of Plate Changer to 1.08 or later too.
- To resolve the issue of SPD-40/40V, update the ROM version of the UV detector to Ver. 2.03 or later.
Note: The [Nexera series] driver does not support other models such as LC-30AD.
5) i-Series LC-2070/LC-2080
| Unit | Model | Minimum required ROM version |
|---|---|---|
| i-Series LC-2070/LC-2080 |
LC-2070, LC-2070C, LC-2070C 3D LC-2080C, LC-2080C 3D |
5.12 |
| Mobile Phase Monitor | MPM-40 | 1.04 |
| External Detector | SPD-M40 *1 | 2.01 |
| RF-20A, RF-20AXS | 2.02 | |
| RID-20A | Old board: 1.04 New board: 2.04 |
- SPD-M40 detector cannot be controlled with LC-2070C 3D or LC-2080C 3D.