Last update: May 9, 2022 GMT

Sample vial
Name P/N Appearance Qty Material Remarks Applicable models
Sample Vials 228-21287-91 100 Borosilicate glass With cap/silicone rubber septum LC-2030
LC-2040
SIL-30AC
SIL-20A
SIL-20AC
SIL-20AHT
SIL-20ACHT
SIL-20AXR
SIL-20ACXR
LC-2010A(HT)
LC-2010C(HT)
Sample Vials 228-31537-91 100 Polypropylene With cap/silicone rubber septum LC-2030
LC-2040
SIL-30AC
SIL-20A
SIL-20AC
SIL-20AHT
SIL-20ACHT
SIL-20AXR
SIL-20ACXR
LC-2010A(HT)
LC-2010C(HT)
Sample Vials 228-15652-92 100 Borosilicate glass With cap/silicone rubber septum LC-2030
LC-2040
SIL-30AC
SIL-30ACMP
SIL-20A
SIL-20AC
SIL-20AHT
SIL-20ACHT
SIL-20AXR
SIL-20ACXR
LC-2010A(HT)
LC-2010C(HT)
Sample Vials 228-21283-91 100 Borosilicate glass With cap/silicone rubber septum LC-2030
LC-2040
SIL-30AC
SIL-30ACMP
SIL-20A
SIL-20AC
SIL-20AHT
SIL-20ACHT
SIL-20AXR
SIL-20ACXR
LC-2010A(HT)
LC-2010C(HT)
Sample Vials 228-39699-91 250 Borosilicate glass With polyethylene cap LC-2030
LC-2040
SIL-30AC
SIL-20A
SIL-20AC
SIL-20AHT
SIL-20ACHT
SIL-20AXR
SIL-20ACXR
LC-2010A(HT)
LC-2010C(HT)
Sample Vials  REPRESENT IMAGE Representative image of the product. It will appear on other page links. Show row weights 200 Polypropylene With polyethylene cap LC-2030
LC-2040
SIL-30AC
SIL-30ACMP
SIL-20A
SIL-20AC
SIL-20AHT
SIL-20ACHT
SIL-20AXR
SIL-20ACXR
LC-2010A(HT)
LC-2010C(HT)
Sample Vials 228-16847-92 100 Borosilicate glass With cap/silicone rubber septum LC-2030
LC-2040
SIL-30AC
SIL-30ACMP
SIL-20A
SIL-20AC
SIL-20AHT
SIL-20ACHT
SIL-20AXR
SIL-20ACXR
LC-2010A(HT)
LC-2010C(HT)
Sample Vials 228-16850-91 100 Borosilicate glass Vials only LC-2030
LC-2040
SIL-30AC
SIL-30ACMP
SIL-20A
SIL-20AC
SIL-20AHT
SIL-20ACHT
SIL-20AXR
SIL-20ACXR
LC-2010A(HT)
LC-2010C(HT)
Sample Vials 228-21284-91 100 Borosilicate glass With spring,To be used in 4mL vials LC-2030
LC-2040
SIL-30AC
SIL-30ACMP
SIL-20A
SIL-20AC
SIL-20AHT
SIL-20ACHT
SIL-20AXR
SIL-20ACXR
LC-2010A(HT)
LC-2010C(HT)
Sample Vials 228-21285-91 100 Borosilicate glass Vials only LC-2030
LC-2040
SIL-30AC
SIL-30ACMP
SIL-20A
SIL-20AC
SIL-20AHT
SIL-20ACHT
SIL-20AXR
SIL-20ACXR
LC-2010A(HT)
LC-2010C(HT)
Sample Vials 228-35217-91 100 Polypropylene With polyethylene cap LC-2030
LC-2040
SIL-30AC
SIL-30ACMP
SIL-20A
SIL-20AC
SIL-20AHT
SIL-20ACHT
SIL-20AXR
SIL-20ACXR
LC-2010A(HT)
LC-2010C(HT)
Septums 100 Silicone rubber w/PTFE cover 228-15652-92
228-15652-92
228-15652-92
228-21283-91
228-21283-91
228-21283-91
228-16847-92
228-16847-92
228-16847-92
Septums 100 PTFE 228-15652-92
228-15652-92
228-15652-92
228-21283-91
228-21283-91
228-21283-91
228-16847-92
228-16847-92
228-16847-92
Septums 100 PTFE 228-21287-91
228-31537-91
Sample plates 2 Plate to set eighty-four 1 mL sample vials. 228-39699-91
Sample plates 2 Plate to set fifty-four 1.5 mL sample vials. 228-15652-92
228-15652-92
228-15652-92
228-21283-91
228-21283-91
228-21283-91
228-35217-91
228-35217-91
228-35217-91
Sample plates 3 Plate to set fifty-four 1.5 mL sample vials. 228-15652-92
228-15652-92
228-15652-92
228-21283-91
228-21283-91
228-21283-91
228-35217-91
228-35217-91
228-35217-91
Sample plates 2 Plate to set twenty-eight 4 mL sample vials. 228-21287-91
228-31537-91

* Sample vial material

There are glass and plastic (polyethylene) sample vials. If a vial is used incorrectly or the selection is incorrect, a problem may occur during analysis. See the following table for use.

Type Characteristic Appropriate Sample Solvent
Glass Ionic material such as an acid or base may be adsorbed to the surface of the glass. Analyzing the ionic material in such a status would deteriorate the accuracy and precision, affecting the reliability of the analysis. In that case, adjust the sample solvent to restrain adsorption of the material. Also, note that alkali or hydrogen fluoride may corrode the glass material.
  • 10 to 100 mmol/L perchloric acid aqueous solution or mixtures of such with an organic solvent. (For the organic solvent, use acetonitrile, methanol, or ethanol.)
  • 10 mmol/L trifluoroacetic acid (TFA) organic solvent. (For the organic solvent, use acetonitrile, methanol, or ethanol. Note that trifluoroacetic acid will be detected when n absorbance is detected between 200 nm and 220 nm.)
Polypropylene The hydrophoby of the material will be a cause of surface adsorption. In this case as well, the accuracy and precision of the analysis will deteriorate, and sample solvents with a higher polarity will be more affected. Using a low polarity sample solvent will restrain the hydrophobic substance from being adsorbed, but if the polarity is too low, the additives in the plastic may elute from the surface of the sample vial. Note that an organic solvent may denaturalize plastic. Mixtures of water or a buffer solution with an organic solvent. Organic solvent composition ratio: 20 % to 50 % (V/V). (For the organic solvent, use acetonitrile, methanol, or ethanol.)
SIL Suction Filter
P/N Appearance Qty Remarks Applicable model Links Applicable models
228-45707-91 LCMS-2010
LC-20AHT
LC-10AF
LC-10AP
LC-10ADvp
LC-10AXL10A
LC-10AF
LC-10AP
LC-10ADvp
LC-10AXL10A
LC-10AF
LC-10AP
LC-10ADvp
LC-HT10A
LC-20ACHT
LC-20ACXR
LC-2040
LC-20AXR
LC-20AC
LC-20A
LC-30ACMP
LC-30AC
LC-40CX3
LC-40CXS
LC-40CXR
LC-40XR
LC-40C
LC-40
LC-2010HT
LC-2010
LC-2030
LC-10AXL
1 Ceramic 10Ai
Needle Seal
P/N Qty Remarks Applicable models
1 PEEK 2030
2030 Plus
2040
2040 Plus
20AXR
20ACXR
optional for 20AHT
optional for 20ACHT
optional for 20AHT(UFLC)
optional for 20ACHT(UFLC) *1)
1 PEEK including housing 2030
2030 Plus
2040
2040 Plus
20AXR
20ACXR
optional for 20AHT
optional for 20ACHT
optional for 20AHT(UFLC)
optional for 20ACHT(UFLC) *1)
3 PEEK including housing 2030
2030 Plus
2040
2040 Plus
20AXR
20ACXR
optional for 20AHT
optional for 20ACHT
optional for 20AHT(UFLC)
optional for 20ACHT(UFLC) *1)
1 Vespel® optional for 2030
optional for 2030 Plus
optional for 2040
optional for 2040 Plus
optional for 20AXR
optional for 20ACXR
1 Vespel® 30AC
30ACMP
3 Vespel® 30AC
30ACMP
1 PEEK MAX 66MPa optional for 30AC
optional for 30ACMP
1 PEEK high pH kit optional for 30AC
optional for 30ACMP
1 PEEK 20AHT
20ACHT
20AHT(UFLC)
20ACHT(UFLC)
20A
20AC
1 Vespel® optional for 20AHT
optional for 20ACHT
optional for 20AHT(UFLC)
optional for 20ACHT(UFLC)
1 PEEK *2) HT
2010HT(current)
1 Vespel® optional for HT
optional for 2010HT(current)
1 PEEK HT
2010HT(previous)
optional for 2010A
optional for 2010C
optional for 10ADVP
optional for 10AXL
1 Vespel® 2010A
2010C
10ADVP
10AXL
3 FEP 10A
10Ai
10AF
10AP

*1) Mounting 228-50390 on the SIL-20AHT/20ACHT (including UFLC) prevents the sample from scattering. In this case, the needle seal XR kit (P/N: 228-50452-92) and ROM version 1.2 or later are necessary.

*2) On the LC-2010HT and SIL-HT (current product), the needle and needle seal have been changed. When changing the existing needle seal (replacing P/N: 228-33355-xx with 228-41540-01), the needle assembly (P/N: 228-41024-93) also needs to be changed. To distinguish between LC-2010HT units, see the photos below. The unit shown to the left is the current product.

 

Vespel® is a registered trademark of DuPont.

Septum for Rinse Port
P/N Qty Remarks Applicable models
100 Same as the septum for 4 mL vials for the SIL-10A 10A
10AF
10AP
10Ai
10AXL
10 With a slit 2010
10ADVP
500 Same as the septum for 4 mL vials for the SIL-10A 10A
10AF
10AP
10Ai
10AXL
Stator and Rotor Seal
Name P/N Appearance Qty Remarks Applicable model Links Applicable models
Rotor Seal 228-71780-42 1 PEEK 40CXS
40CX3
40XR
40CXR
FCV-0206H
FCV-0206H3
Rotor Seal 1 Vespel® 10ADVP
Rotor Seal 1 Delrin®, for above pH10 optional for 2010
Rotor Seal 1 Vespel® 2010 (with extended loop)
Rotor Seal 1 Vespel® 2010
Rotor Seal 1 Tefzel®, for above pH10 optional for 10Ai
Rotor Seal 1 PEEK 10ADVP (with carryover reduction kit)
Rotor Seal 1 Delrin®, for above pH10 10ADVP
Rotor Seal 1 Vespel® 10AP
Rotor Seal 228-71780-41 1 PEEK 40
40C
FCV-0206
Rotor Seal 1 Delrin®, for above pH10 optional for 10A
optional for 10AXL
optional for 10AF
Rotor Seal 1 Vespel® 10A
10AXL
10AF
Rotor Seal 228-41310-92 1 PEEK 20A
20AC
20AHT
20ACHT(UFLC)
HT
2010HT(with extended loop)
Rotor Seal 228-52139 1 PEEK 30AC
30ACMP
FCV-32AH
Rotor Seal 1 PEEK 2030
Rotor Seal 228-48854 1 PEEK 2040
2040 Plus
20AXR
20ACXR
2040
20AXR
20ACXR
SFE-30A
Rotor Seal 1 Delrin®, for above pH10 optional for 2010 (with extended loop)
Stator 228-48858-46 1 SUS316L with special coating FCV-0206H
FCV-0206H3
40CXS
40CX3
40XR
40CXR
Stator 228-56253-44 1 SUS316L with special coating 40
40C
FCV-0206
Stator 1 SUS316L with special coating 2030
2030 Plus
Stator 1 SUS316L with special coating 2040
2040 Plus
Stator 1 SUS316L with special coating 30AC
30ACMP
Stator 228-48858-91 Special coating 20AXR
20ACXR
Stator 1 Ceramic 20A
20AC
20AHT(UFLC)
20ACHT(UFLC)
Stator 228-45408-91 1 Ceramic with valve head 20A
20AC
Stator 228-45408-93 1 Ceramic with valve head and packing 20AHT(UFLC)
20ACHT(UFLC)
Stator 1 Ceramic for above pH10, with packing optional for 10A
optional for 10AXL
optional for 10AF
optional for 10ADVP
Stator 1 Ceramic with packing 10ADVP
Stator 1 Ceramic with valve head and packing 10ADVP (with carryover reduction kit)
Stator 228-32511-33 1 Ceramic with packing 10Ai
FCV-12AHi
Stator 1 SUS316 with valve head and packing 2010
Stator 1 SUS316L with valve head and packing 2010
Stator 1 Ceramic with valve head and packing HT
2010HT
Mass Spec Sample Vials
Name P/N Qty Remarks Applicable models
LabTotal Vial
Certified Kit
100 Packed with Mass Spec Quality Certificate.
Suitable for LC-20A, LC-30A, LC-2010, LC-2030,
LC-2040 and later.
For detailed information, please click here.
LC-20A
LC-30A
LC-2010
LC-2030
LC-2040

Supplementary keywords: plastic vial, plastic, septa, HPLC, high-performance liquid chromatograph, LC-30AD, LC-20AD,LC-20AT,LC-20AB,LC-20AP,LC-20ADnano,LC-20ADXR,LC-20ADsp, LC-2010,LC-2010A,LC-2010C, auto sampler, autosampler sampler, Injector, autoinjector, sampler, SIL-20A, SIL-10A, SIL-HT, high throughput, LC-2010, inert, suction filter, ceramic filter, LC-2030, LC-2040, LC-2010HT, SIL-40, SIL-40C, SIL40XR, SIL-40CXR, SIL-40CXS, SIL-40CX3, SIL-30AC, SIL-30ACMP, Nexera-i, Prominence-i, needle, high throughput, inert injector, Vespel, PEEK, SIL-30A, Injector, septum, rinse port, SIL, SIL-10AD, LC-2010HT, valve, stator, rotor, seal, SIL-40XR, SIL-20ACMP