SIL (autosampler)
Share
Share
Add Bookmark
Last update: May 9, 2022 GMT
Name | P/N | Appearance | Qty | Material | Remarks | Applicable models |
---|---|---|---|---|---|---|
Sample Vials |
228-21287-91
|
100 | Borosilicate glass | With cap/silicone rubber septum |
LC-2030 LC-2040 SIL-30AC SIL-20A SIL-20AC SIL-20AHT SIL-20ACHT SIL-20AXR SIL-20ACXR LC-2010A(HT) LC-2010C(HT) |
|
Sample Vials |
228-31537-91
|
100 | Polypropylene | With cap/silicone rubber septum |
LC-2030 LC-2040 SIL-30AC SIL-20A SIL-20AC SIL-20AHT SIL-20ACHT SIL-20AXR SIL-20ACXR LC-2010A(HT) LC-2010C(HT) |
|
Sample Vials |
228-15652-92
|
100 | Borosilicate glass | With cap/silicone rubber septum |
LC-2030 LC-2040 SIL-30AC SIL-30ACMP SIL-20A SIL-20AC SIL-20AHT SIL-20ACHT SIL-20AXR SIL-20ACXR LC-2010A(HT) LC-2010C(HT) |
|
Sample Vials |
228-21283-91
|
100 | Borosilicate glass | With cap/silicone rubber septum |
LC-2030 LC-2040 SIL-30AC SIL-30ACMP SIL-20A SIL-20AC SIL-20AHT SIL-20ACHT SIL-20AXR SIL-20ACXR LC-2010A(HT) LC-2010C(HT) |
|
Sample Vials |
228-39699-91
|
250 | Borosilicate glass | With polyethylene cap |
LC-2030 LC-2040 SIL-30AC SIL-20A SIL-20AC SIL-20AHT SIL-20ACHT SIL-20AXR SIL-20ACXR LC-2010A(HT) LC-2010C(HT) |
|
Sample Vials |
228-31600-91
|
200 | Polypropylene | With polyethylene cap |
LC-2030 LC-2040 SIL-30AC SIL-30ACMP SIL-20A SIL-20AC SIL-20AHT SIL-20ACHT SIL-20AXR SIL-20ACXR LC-2010A(HT) LC-2010C(HT) |
|
Sample Vials |
228-16847-92
|
100 | Borosilicate glass | With cap/silicone rubber septum |
LC-2030 LC-2040 SIL-30AC SIL-30ACMP SIL-20A SIL-20AC SIL-20AHT SIL-20ACHT SIL-20AXR SIL-20ACXR LC-2010A(HT) LC-2010C(HT) |
|
Sample Vials |
228-16850-91
|
100 | Borosilicate glass | Vials only |
LC-2030 LC-2040 SIL-30AC SIL-30ACMP SIL-20A SIL-20AC SIL-20AHT SIL-20ACHT SIL-20AXR SIL-20ACXR LC-2010A(HT) LC-2010C(HT) |
|
Sample Vials |
228-21284-91
|
100 | Borosilicate glass | With spring,To be used in 4mL vials |
LC-2030 LC-2040 SIL-30AC SIL-30ACMP SIL-20A SIL-20AC SIL-20AHT SIL-20ACHT SIL-20AXR SIL-20ACXR LC-2010A(HT) LC-2010C(HT) |
|
Sample Vials |
228-21285-91
|
100 | Borosilicate glass | Vials only |
LC-2030 LC-2040 SIL-30AC SIL-30ACMP SIL-20A SIL-20AC SIL-20AHT SIL-20ACHT SIL-20AXR SIL-20ACXR LC-2010A(HT) LC-2010C(HT) |
|
Sample Vials |
228-35217-91
|
100 | Polypropylene | With polyethylene cap |
LC-2030 LC-2040 SIL-30AC SIL-30ACMP SIL-20A SIL-20AC SIL-20AHT SIL-20ACHT SIL-20AXR SIL-20ACXR LC-2010A(HT) LC-2010C(HT) |
|
Septums |
221-26718-93
|
100 | Silicone rubber w/PTFE cover |
228-15652-92 228-15652-92 228-15652-92 228-21283-91 228-21283-91 228-21283-91 228-16847-92 228-16847-92 228-16847-92 |
||
Septums |
228-15655-91
|
100 | PTFE |
228-15652-92 228-15652-92 228-15652-92 228-21283-91 228-21283-91 228-21283-91 228-16847-92 228-16847-92 228-16847-92 |
||
Septums |
228-23469-91
|
100 | PTFE |
228-21287-91 228-31537-91 |
||
Sample plates |
228-56197-41
|
2 | Plate to set eighty-four 1 mL sample vials. |
228-39699-91 |
||
Sample plates |
228-50830-92
|
2 | Plate to set fifty-four 1.5 mL sample vials. |
228-15652-92 228-15652-92 228-15652-92 228-21283-91 228-21283-91 228-21283-91 228-35217-91 228-35217-91 228-35217-91 |
||
Sample plates |
228-50830-91
|
3 | Plate to set fifty-four 1.5 mL sample vials. |
228-15652-92 228-15652-92 228-15652-92 228-21283-91 228-21283-91 228-21283-91 228-35217-91 228-35217-91 228-35217-91 |
||
Sample plates |
228-56197-42
|
2 | Plate to set twenty-eight 4 mL sample vials. |
228-21287-91 228-31537-91 |
* Sample vial material
There are glass and plastic (polyethylene) sample vials. If a vial is used incorrectly or the selection is incorrect, a problem may occur during analysis. See the following table for use.
Type | Characteristic | Appropriate Sample Solvent |
---|---|---|
Glass | Ionic material such as an acid or base may be adsorbed to the surface of the glass. Analyzing the ionic material in such a status would deteriorate the accuracy and precision, affecting the reliability of the analysis. In that case, adjust the sample solvent to restrain adsorption of the material. Also, note that alkali or hydrogen fluoride may corrode the glass material. |
|
Polypropylene | The hydrophoby of the material will be a cause of surface adsorption. In this case as well, the accuracy and precision of the analysis will deteriorate, and sample solvents with a higher polarity will be more affected. Using a low polarity sample solvent will restrain the hydrophobic substance from being adsorbed, but if the polarity is too low, the additives in the plastic may elute from the surface of the sample vial. Note that an organic solvent may denaturalize plastic. | Mixtures of water or a buffer solution with an organic solvent. Organic solvent composition ratio: 20 % to 50 % (V/V). (For the organic solvent, use acetonitrile, methanol, or ethanol.) |
P/N | Appearance | Qty | Remarks | Applicable model Links | Applicable models |
---|---|---|---|---|---|
228-45707-91
|
LCMS-2010 LC-20AHT LC-10AF LC-10AP LC-10ADvp LC-10AXL10A LC-10AF LC-10AP LC-10ADvp LC-10AXL10A LC-10AF LC-10AP LC-10ADvp LC-HT10A LC-20ACHT LC-20ACXR LC-2040 LC-20AXR LC-20AC LC-20A LC-30ACMP LC-30AC LC-40CX3 LC-40CXS LC-40CXR LC-40XR LC-40C LC-40 LC-2010HT LC-2010 LC-2030 LC-10AXL |
||||
228-20946-91
|
1 | Ceramic |
10Ai |
P/N | Qty | Remarks | Applicable models |
---|---|---|---|
228-50390
|
1 | PEEK |
2030 2030 Plus 2040 2040 Plus 20AXR 20ACXR optional for 20AHT optional for 20ACHT optional for 20AHT(UFLC) optional for 20ACHT(UFLC) *1) |
228-50452-92
|
1 | PEEK including housing |
2030 2030 Plus 2040 2040 Plus 20AXR 20ACXR optional for 20AHT optional for 20ACHT optional for 20AHT(UFLC) optional for 20ACHT(UFLC) *1) |
228-50452-93
|
3 | PEEK including housing |
2030 2030 Plus 2040 2040 Plus 20AXR 20ACXR optional for 20AHT optional for 20ACHT optional for 20AHT(UFLC) optional for 20ACHT(UFLC) *1) |
228-50390-41
|
1 | Vespel® |
optional for 2030 optional for 2030 Plus optional for 2040 optional for 2040 Plus optional for 20AXR optional for 20ACXR |
228-52253
|
1 | Vespel® |
30AC 30ACMP |
228-52401-92
|
3 | Vespel® |
30AC 30ACMP |
228-53178-91
|
1 | PEEK MAX 66MPa |
optional for 30AC optional for 30ACMP |
228-57729-41
|
1 | PEEK high pH kit |
optional for 30AC optional for 30ACMP |
228-42325-01
|
1 | PEEK |
20AHT 20ACHT 20AHT(UFLC) 20ACHT(UFLC) 20A 20AC |
228-48258-91
|
1 | Vespel® |
optional for 20AHT optional for 20ACHT optional for 20AHT(UFLC) optional for 20ACHT(UFLC) |
228-41540-01
|
1 | PEEK *2) |
HT 2010HT(current) |
228-41540-04
|
1 | Vespel® |
optional for HT optional for 2010HT(current) |
228-33355-01
|
1 | PEEK |
HT 2010HT(previous) optional for 2010A optional for 2010C optional for 10ADVP optional for 10AXL |
228-33355-04
|
1 | Vespel® |
2010A 2010C 10ADVP 10AXL |
228-21227-91
|
3 | FEP |
10A 10Ai 10AF 10AP |
*1) Mounting 228-50390 on the SIL-20AHT/20ACHT (including UFLC) prevents the sample from scattering. In this case, the needle seal XR kit (P/N: 228-50452-92) and ROM version 1.2 or later are necessary.
*2) On the LC-2010HT and SIL-HT (current product), the needle and needle seal have been changed. When changing the existing needle seal (replacing P/N: 228-33355-xx with 228-41540-01), the needle assembly (P/N: 228-41024-93) also needs to be changed. To distinguish between LC-2010HT units, see the photos below. The unit shown to the left is the current product.
P/N | Qty | Remarks | Applicable models |
---|---|---|---|
228-21290-91
|
100 | Same as the septum for 4 mL vials for the SIL-10A |
10A 10AF 10AP 10Ai 10AXL |
228-36215-91
|
10 | With a slit |
2010 10ADVP |
228-21290-84
|
500 | Same as the septum for 4 mL vials for the SIL-10A |
10A 10AF 10AP 10Ai 10AXL |
Name | P/N | Appearance | Qty | Remarks | Applicable model Links | Applicable models |
---|---|---|---|---|---|---|
Rotor Seal |
228-71780-42
|
1 | PEEK |
40CXS 40CX3 40XR 40CXR FCV-0206H FCV-0206H3 |
||
Rotor Seal |
228-21217-97
|
1 | Vespel® |
10ADVP |
||
Rotor Seal |
228-38556-02
|
1 | Delrin®, for above pH10 |
optional for 2010 |
||
Rotor Seal |
228-38556-03
|
1 | Vespel® |
2010 (with extended loop) |
||
Rotor Seal |
228-38556-01
|
1 | Vespel® |
2010 |
||
Rotor Seal |
228-32511-32
|
1 | Tefzel®, for above pH10 |
optional for 10Ai |
||
Rotor Seal |
228-41290-91
|
1 | PEEK |
10ADVP (with carryover reduction kit) |
||
Rotor Seal |
228-21708-92
|
1 | Delrin®, for above pH10 |
10ADVP |
||
Rotor Seal |
228-21217-93
|
1 | Vespel® |
10AP |
||
Rotor Seal |
228-71780-41
|
1 | PEEK |
40 40C FCV-0206 |
||
Rotor Seal |
228-21217-92
|
1 | Delrin®, for above pH10 |
optional for 10A optional for 10AXL optional for 10AF |
||
Rotor Seal |
228-21217-91
|
1 | Vespel® |
10A 10AXL 10AF |
||
Rotor Seal |
228-41310-92
|
1 | PEEK |
20A 20AC 20AHT 20ACHT(UFLC) HT 2010HT(with extended loop) |
||
Rotor Seal |
228-52139
|
1 | PEEK |
30AC 30ACMP FCV-32AH |
||
Rotor Seal |
228-56098
|
1 | PEEK |
2030 |
||
Rotor Seal |
228-48854
|
1 | PEEK |
2040 2040 Plus 20AXR 20ACXR 2040 20AXR 20ACXR SFE-30A |
||
Rotor Seal |
228-38556-04
|
1 | Delrin®, for above pH10 |
optional for 2010 (with extended loop) |
||
Stator |
228-48858-46
|
1 | SUS316L with special coating |
FCV-0206H FCV-0206H3 40CXS 40CX3 40XR 40CXR |
||
Stator |
228-56253-44
|
1 | SUS316L with special coating |
40 40C FCV-0206 |
||
Stator |
228-59076-41
|
1 | SUS316L with special coating |
2030 2030 Plus |
||
Stator |
228-56253-42
|
1 | SUS316L with special coating |
2040 2040 Plus |
||
Stator |
228-48858-95
|
1 | SUS316L with special coating |
30AC 30ACMP |
||
Stator |
228-48858-91
|
Special coating |
20AXR 20ACXR |
|||
Stator |
228-40259-01
|
1 | Ceramic |
20A 20AC 20AHT(UFLC) 20ACHT(UFLC) |
||
Stator |
228-45408-91
|
1 | Ceramic with valve head |
20A 20AC |
||
Stator |
228-45408-93
|
1 | Ceramic with valve head and packing |
20AHT(UFLC) 20ACHT(UFLC) |
||
Stator |
228-21220-93
|
1 | Ceramic for above pH10, with packing |
optional for 10A optional for 10AXL optional for 10AF optional for 10ADVP |
||
Stator |
228-21220-94
|
1 | Ceramic with packing |
10ADVP |
||
Stator |
228-41185-91
|
1 | Ceramic with valve head and packing |
10ADVP (with carryover reduction kit) |
||
Stator |
228-32511-33
|
1 | Ceramic with packing |
10Ai FCV-12AHi |
||
Stator |
228-40254-91
|
1 | SUS316 with valve head and packing |
2010 |
||
Stator |
228-40254-93
|
1 | SUS316L with valve head and packing |
2010 |
||
Stator |
228-41185-92
|
1 | Ceramic with valve head and packing |
HT 2010HT |
Supplementary keywords: plastic vial, plastic, septa, HPLC, high-performance liquid chromatograph, LC-30AD, LC-20AD,LC-20AT,LC-20AB,LC-20AP,LC-20ADnano,LC-20ADXR,LC-20ADsp, LC-2010,LC-2010A,LC-2010C, auto sampler, autosampler sampler, Injector, autoinjector, sampler, SIL-20A, SIL-10A, SIL-HT, high throughput, LC-2010, inert, suction filter, ceramic filter, LC-2030, LC-2040, LC-2010HT, SIL-40, SIL-40C, SIL40XR, SIL-40CXR, SIL-40CXS, SIL-40CX3, SIL-30AC, SIL-30ACMP, Nexera-i, Prominence-i, needle, high throughput, inert injector, Vespel, PEEK, SIL-30A, Injector, septum, rinse port, SIL, SIL-10AD, LC-2010HT, valve, stator, rotor, seal, SIL-40XR, SIL-20ACMP