Greenhouse gases are those that are found in the atmosphere that induce the greenhouse effect, which is an absorbance and emission of infrared energy emitted by the Earth. As sunlight strikes the surface of the Earth, some of the infrared light is reflected into the atmosphere. These greenhouse gases absorb that infrared energy and reflect it toward the Earth. This gas chromatograph system enables the easy qualitative and quantitative analysis of three major greenhouse gases: methane(CH4), carbon dioxide(CO2), and nitrous oxide(N2O).
Green House Gas Analyzer Lineup
Model Name | Conventional GHC system | NARO x Shimadzu System1 | Jetanizer-FID & ECD System |
---|---|---|---|
Features |
・Conventional GHG analysis |
・High throughput analysis |
・High throughput analysis |
Selection Guide |
・Small number of samples |
・Large number of samples |
・Large number of samples |
GC model | GC-2014 | GC-2014 | GC-2030 |
Analysis time / GC cycle time |
12/14 min |
7/9 min (Isothermal) |
3/5 min (Isothermal) |
Area repeatability | 0.5%RSD | 0.5%RSD | 1%RSD |
Detector |
Methanizer FID |
FID |
Jetanizer FID |
LOD |
CH4: 1ppm CO2: 1ppm N2O: 0.05ppm |
CH4: 0.1ppm CO2: 100ppm N2O: 0.05ppm |
CH4: 0.4ppm CO2: 0.4ppm N2O: 0.1ppm |
Column | Packed column | Packed column | Capillary column |
Notes: National Agriculture and Food Research Organization.
This system was developed in collaboration with Dr. Shigeto Sudo at NARO.
Caution: Available systems vary by region.
Common Items
GC Type | Applicated GC/Analyzer |
---|---|
Sampling technique | Sampling bag or on-line sampling with gas sampling valve injection Vial sampling with syringe injection by autosampler |
Carrier gas | N2 |
Detector gas |
FID; Air、H2、N2 |
News / Events
-
Shimadzu has released the Brevis™ GC-2050
"Smaller, simpler, and easier to use – without compromising performance." That’s the demand from analysts. And that’s why Shimadzu developed the Brevis GC-2050. This new space-saving GC delivers uncompromising analytical performance in a modern yet rugged design, easily meeting the analysis needs of laboratories in a range of industries.
-
Latest issue of Shimadzu Journal, featuring Forensics / Toxicology, has come out.
This issue focuses on "Forensics / Toxicology", an area where science and technology are particularly important and needed. It starts with two customer interviews.
-
Air
Shimadzu provides analytical equipment and solutions that can monitor not only the atmospheric environment, but also indoor working environments and direct emission sources. Here are some examples of measurements of inorganic and organic components in the air and indoor environment.
-
Cosmetics and Personal Care Products
The environment surrounding cosmetics and personal care products is changing. In addition to serving the original aesthetic purpose, cosmetics are required to be environmentally friendly and impart no adverse effects on animals.
-
Shimadzu has released GC Driver Ver. 2.3 with Thermo Scientific™ Chromeleon™ Compatibility
Chromeleon chromatography data systems can now be used to control AOC-30 autoinjectors in Shimadzu Nexis™ GC-2030 systems and perform packed column analysis.
-
Shimadzu has released GC Driver Ver. 3.2 with Waters Empower™ Compatibility
Waters Empower chromatography data systems can now be used to control AOC-30 autoinjectors in Shimadzu Nexis™ GC-2030 systems and perform packed column analysis.