Gas Chromatograph-Mass Spectrometry

    Basics of Gas Chromatography/Mass Spectrometry 

    Gas chromatography/mass spectrometry (GC/MS) is an analytical technique that combines gas-chromatography (GC) and mass spectrometry (MS) to identify unknown substances or contaminants. MS is a highly sensitive detection technique that forms, separates and detects ions in the gaseous phase.

    When coupled to a GC as a GC-MS instrument, it immediately ionizes the gaseous eluted compounds, separates the ions in vacuum based on their mass-to-charge ratios (m/z) and eventually measures the intensity of each ion. MS is one of many GC detectors, but unlike other detectors, it can perform both quantitative and qualitative analyses. With dedicated software, GC-MS instruments can calculate accurate mass and estimate molecular composition. This is extremely valuable for the unique identification of molecules, also known as qualitative analysis. GC/MS testing provides added specificity, sensitivity, and the convenience of simultaneous multi-component analysis. This is applicable to many industries, such as environmental, forensic, food and beverage, clinical, pharmaceutical, and chemical. It is commonly used for the direct separation and analysis of air samples and is often labeled as the accepted technique or gold standard for separation and analysis.

    Frequently Asked Questions

    How is GC/MS used for drug testing?

    Gas chromatography/mass spectrometry (GC/MS) is commonly used in forensic, medical and workplace applications as it’s a highly accurate technique for detecting and identifying drugs and metabolites in biological samples – the results being acceptable in a court of law. This analytical technique uses GC-MS instruments to provide qualitative and quantitative data pertaining to sample materials – including mere trace amounts – as they are ideal for analyzing urine, blood and saliva for drug contamination to gain highly accurate and detailed results.

    What information can be obtained utilizing GC/MS?

    GC/MS testing is specifically used for the analysis of volatile and low-molecular-weight compounds with a molecular weight of less than 1000. The high accuracy of the GC/MS process allows it to precisely analyze a sample’s molecular composition, detecting and measuring even the smallest trace molecules. The high accuracy of the GC/MS process allows it to precisely detect and measure even the smallest trace molecules, providing detailed information about the chemical composition of a sample. GC-MS offers exceptional separation performance and allows incredible accuracy in distinguishing between substances, even in highly complex mixtures. This is why GC-MS instruments are frequently used in forensic toxicology and pharmaceutical quality control, as GC/MS reveals even the most minuscule amounts of contaminants, such as allergens in cosmetics. Software can calculate the accurate mass and estimate the molecular composition of the sample mixture, highlighting why GC/MS testing is an invaluable analytical tool across numerous industries.

    How accurate are the GCMS results for drug analysis?

    GC/MS is widely regarded as the gold standard for drug testing due to its low risk of false positives, which results from matching using complete mass spectra. This accurate and precise analytical tool offers a high level of certainty in drug testing as it can identify and quantify even trace amounts of substances in samples. GC-MS instruments are frequently utilized for drug testing, but their accuracy is also prized in clinical research and environmental, food and beverage and pharmaceutical testing.

    How long is the typical GCMS run time for drug analysis?

    The detection time of GC/MS drug tests depends on several factors, including the type of drug present, the sample matrix – whether urine, blood or saliva – and the sample pretreatment. Shimadzu’s GC-MS systems can offer 40-minute analysis cycles for drugs containing more than 1000 substances. This fast analysis, combined with analytical sensitivity, is why GC/MS is valuable for law enforcement, healthcare professionals and cross-industry employers. 

    How does GC/MS work?

    GC/MS analysis begins with GC. The sample mixture is injected into the chromatograph and vaporized into gaseous compounds. This then flows into a thermally controlled column with inert gas. Here, with the continual flow of gas, the compounds are separated based on their boiling points and differential adsorption on a porous solid or liquid support. At this point, the separated compounds are eluted (or removed) from the column, entering the MS phase. The gaseous eluted compounds are immediately ionized and fragmented based on their mass-to-charge ratios, so the intensity of each ion can be measured and recorded in a series of mass spectra. To sum up the intensities of all mass spectral peaks in the sample, GC-MS instruments produce a mass chromatogram, giving users an incredibly detailed and accurate sample analysis. 

    It’s important to note that MS is one of many GC detectors, but unlike others, it can perform both quantitative and qualitative analyses. GC/MS testing separates and quantifies multi-component samples and complex matrices and has the capability to identify unknown compounds – a clear indicator of the precision and reliability advantages of GC/MS. Data obtained from GC-MS equipment, such as retention time, molecular weight and mass spectra, can be retrieved and used for a spectral library search. Plus, with specific software, the instruments can calculate the accurate mass and estimate the molecular composition, highlighting how valuable GC/MS testing is for precise and detailed analysis in various applications, including drug testing, environmental monitoring and clinical research.  

    Read more
    Show Less

     