LC/MS/MS Method Package for Restricted Chemicals in Textiles
For LabSolutions™ LCMS Software
Various restricted chemicals in textiles can be detected.
In recent years, while many issues have been raised related to food safety and the environment, the safety of textiles, which are indispensable for everyday life, has become a particular concern. Countries throughout the world, and especially in the EU, are regulating and investigating hazardous chemicals in textiles. Additionally, regulations have been tightened with respect to hazardous chemicals in textiles. This includes the adoption of the OEKO-TEX® Standard 100, a globally consolidated, independent examination and authentication system for textiles, and the implementation of voluntary regulations by various manufacturers. In addition to the currently regulated components, this method package provides analysis methods covering the major compounds in the OEKO-TEX® Standard 100 and voluntary regulations by various manufacturers.
- Certain Aromatic Amines: 24 compounds
This contains MRM information on 24 compounds, consisting of 2,4-xylidine and 2,6-xylidine in addition to 22 compounds targeted by regulations in the EU. It covers compounds targeted by regulations in a variety of countries including China and Japan.
- Azo Dyes: 51 compounds
This targets compounds that are listed in the OEKO-TEX® Standard 100 and other regulations as carcinogenic dyes and allergic dyes. Additionally, it covers 27 compounds noted in EU Directive 2009/567/EC.
- Perfluoro Compounds: 24 compounds
This targets PFOS and PFOA, which are included in the regulations, as well as their related salts, and even perfluoro compounds that are not included in the regulations at present.
- Alkylphenol Ethoxylate (APEO): 2 compounds Alkylphenol (AP): 4 compounds
This covers 2 compounds-nonylphenol ethoxylate and octylphenol ethoxylate, listed in ISO18254, and the 4 main alkylphenols.
Shared Analytical Columns
This method package contains 6 methods. A shared column is used for the 5 analyses, excluding the certain aromatic amines. Additionally, the mobile phases are shared as much as possible, with 4 aqueous solvents and 2 organic solvents. As shown in the figure below, introducing a column switching system enables the analysis of all the components targeted by this product, just by changing the combination of the mobile phase and column.
Example of a System Configuration Using Column Switching
Overview of the Methods Contained in This Method Package
Method 1 | Method 2 | Method 3 | Method 4 | Method 5 | Method 6 | |
---|---|---|---|---|---|---|
Target Compounds |
24 certain aromatic amines |
44 azo dyes | 7 azo dyes | 24 perfluoro compounds |
2 APEOs | 4 APs |
Column | Shim-pack FC-ODS (2.1 mmID x 150 mm, 3 µm) |
Shim-pack FC-ODS (2.1 mmID x 75 mm, 3 µm) |
Shim-pack FC-ODS (2.1 mmID x 75 mm, 3 µm) |
Shim-pack FC-ODS (2.1 mmID x 75 mm, 3 µm) |
Shim-pack FC-ODS (2.1 mmID x 75 mm, 3 µm) |
Shim-pack FC-ODS (2.1 mmID x 75 mm, 3 µm) |
Mobile Phase A | 5 mmol/L ammonium acetate-water |
5 mmol/L ammonium acetate-water |
5 mmol/L ammonium bicarbonate-water |
5 mmol/L ammonium acetate-water |
10 mmol/L ammonium acetate-water |
Water |
Mobile Phase B | Acetonitrile |
5 mmol/L ammonium
acetate-acetonitrile: ( 9 : 1)
|
Acetonitrile | Acetonitrile | Acetonitrile | Acetonitrile |
Run Time | 13 min | 20 min | 10 min | 13 min | 7 min | 11 min |
Precautions
LabSolutions LCMS Ver. 5.93 or later is required.
LabSolutions and Shim-pack are trademarks of Shimadzu Corporation.
The OEKO-TEX® label is an internationally registered trademark legally protected by the Madrid Agreement.
News / Events
-
Three Analytical and Measuring Instruments Win the Internationally Recognized “iF Design Award 2024”
The Shimadzu LCMS-2050 high-performance liquid chromatograph mass spectrometer, the Brevis GC-2050 gas chromatograph, and the ICPMS-2040/2050 ICP mass spectrometer won the internationally recognized iF Design Award 2024 in the product design category.
-
GCMS-QP2050 Gas Chromatograph Mass Spectrometer Video has released
The business environments and needs involved in analysis work change on a continual basis. The next-generation GCMS-QP2050 gas chromatograph mass spectrometer, with its accumulation of impressive Shimadzu technology, will lead the way forward. New value is provided by hardware boasting astounding reliability and stability, and easy-to-operate software equipped with superior automated technology.
-
OAD-TOF system Interview with Dr.Hiroshi Tsugawa
The OAD-TOF system is a Q-TOF LCMS that realizes OAD (Oxygen Attachment Dissociation), Shimadzu's proprietary fragmentation technology. It allows the analysis of the position of carbon-carbon double bonds in lipids and other organic compounds. Combined with the LCMS -9050, which boasts world-class high mass accuracy and fast polarity switching, it enables the creation of innovative applications.
-
Metabolic Pathway Analysis Solutions
Metabolic pathways are the chain of chemical and enzymatic reactions that occur within a cell in living organisms to support their life.
-
AOAC INTERNATIONAL Posters are now available.
-
Shimadzu has released the OAD-TOF system
The OAD-TOF system is a Q-TOF LCMS that realizes OAD (Oxygen Attachment Dissociation), Shimadzu's proprietary fragmentation technology. It allows the analysis of the position of carbon-carbon double bonds in lipids and other organic compounds. Combined with the LCMS-9050, which boasts world-class high mass accuracy and fast polarity switching, it enables the creation of innovative applications.