LC/MS/MS Method Package for Restricted Chemicals in Textiles
For LabSolutions™ LCMS Software
Various restricted chemicals in textiles can be detected.
In recent years, while many issues have been raised related to food safety and the environment, the safety of textiles, which are indispensable for everyday life, has become a particular concern. Countries throughout the world, and especially in the EU, are regulating and investigating hazardous chemicals in textiles. Additionally, regulations have been tightened with respect to hazardous chemicals in textiles. This includes the adoption of the OEKO-TEX® Standard 100, a globally consolidated, independent examination and authentication system for textiles, and the implementation of voluntary regulations by various manufacturers. In addition to the currently regulated components, this method package provides analysis methods covering the major compounds in the OEKO-TEX® Standard 100 and voluntary regulations by various manufacturers.
- Certain Aromatic Amines: 24 compounds
This contains MRM information on 24 compounds, consisting of 2,4-xylidine and 2,6-xylidine in addition to 22 compounds targeted by regulations in the EU. It covers compounds targeted by regulations in a variety of countries including China and Japan.
- Azo Dyes: 51 compounds
This targets compounds that are listed in the OEKO-TEX® Standard 100 and other regulations as carcinogenic dyes and allergic dyes. Additionally, it covers 27 compounds noted in EU Directive 2009/567/EC.
- Perfluoro Compounds: 24 compounds
This targets PFOS and PFOA, which are included in the regulations, as well as their related salts, and even perfluoro compounds that are not included in the regulations at present.
- Alkylphenol Ethoxylate (APEO): 2 compounds Alkylphenol (AP): 4 compounds
This covers 2 compounds-nonylphenol ethoxylate and octylphenol ethoxylate, listed in ISO18254, and the 4 main alkylphenols.
Shared Analytical Columns
This method package contains 6 methods. A shared column is used for the 5 analyses, excluding the certain aromatic amines. Additionally, the mobile phases are shared as much as possible, with 4 aqueous solvents and 2 organic solvents. As shown in the figure below, introducing a column switching system enables the analysis of all the components targeted by this product, just by changing the combination of the mobile phase and column.
Example of a System Configuration Using Column Switching
Overview of the Methods Contained in This Method Package
Method 1 | Method 2 | Method 3 | Method 4 | Method 5 | Method 6 | |
---|---|---|---|---|---|---|
Target Compounds |
24 certain aromatic amines |
44 azo dyes | 7 azo dyes | 24 perfluoro compounds |
2 APEOs | 4 APs |
Column | Shim-pack FC-ODS (2.1 mmID x 150 mm, 3 µm) |
Shim-pack FC-ODS (2.1 mmID x 75 mm, 3 µm) |
Shim-pack FC-ODS (2.1 mmID x 75 mm, 3 µm) |
Shim-pack FC-ODS (2.1 mmID x 75 mm, 3 µm) |
Shim-pack FC-ODS (2.1 mmID x 75 mm, 3 µm) |
Shim-pack FC-ODS (2.1 mmID x 75 mm, 3 µm) |
Mobile Phase A | 5 mmol/L ammonium acetate-water |
5 mmol/L ammonium acetate-water |
5 mmol/L ammonium bicarbonate-water |
5 mmol/L ammonium acetate-water |
10 mmol/L ammonium acetate-water |
Water |
Mobile Phase B | Acetonitrile |
5 mmol/L ammonium
acetate-acetonitrile: ( 9 : 1)
|
Acetonitrile | Acetonitrile | Acetonitrile | Acetonitrile |
Run Time | 13 min | 20 min | 10 min | 13 min | 7 min | 11 min |
Precautions
LabSolutions LCMS Ver. 5.93 or later is required.
LabSolutions and Shim-pack are trademarks of Shimadzu Corporation.
The OEKO-TEX® label is an internationally registered trademark legally protected by the Madrid Agreement.
News / Events
-
New High Resolution Accurate Mass Library for Forensic Toxicology
Perform forensic toxicology screening for drugs of abuse, psychotropic drugs, pharmaceuticals, pesticides, and natural toxins using this high-resolution accurate mass database.
-
Shimadzu has released the Shim-vial™ H glass, S glass.
Shimadzu provides high-quality vials that thoroughly eliminate these risks by visually inspecting each vial, allowing them to be used with confidence.
-
INTERNATIONAL MASS SPECTROMETRY CONFERENCE 2024
Visit the Shimadzu booth at the International Mass Spectrometry Conference (IMSC) 2024.
-
Metabolomics 2024
Shimadzu Lunch Presentation at Metabolomics 2024
Date: June 20th, 2024 (Thursday)
Time: 12:25 – 1:25 p.m. -
New LabSolutions Insight Biologics
Supporting Innovation with Oligonucleotide Therapeutics
-
Shimadzu has released the LCMS-TQ RX Series High-Performance Liquid Chromatograph Mass Spectrometers
Innovative technology, exceptional design and new ways of thinking are part of our engineering DNA delivering solutions for the ever-changing needs of any laboratory. As our scientific and business needs change our engineering design evolves and adapts. The result is the RX Series of triple quadrupole LC-MS instruments designed with unmatched capability, redefined reliability and creating a new standard in actionable data.