LC/MS/MS Method Package for Restricted Chemicals in Textiles
For LabSolutions™ LCMS Software
Various restricted chemicals in textiles can be detected.

In recent years, while many issues have been raised related to food safety and the environment, the safety of textiles, which are indispensable for everyday life, has become a particular concern. Countries throughout the world, and especially in the EU, are regulating and investigating hazardous chemicals in textiles. Additionally, regulations have been tightened with respect to hazardous chemicals in textiles. This includes the adoption of the OEKO-TEX® Standard 100, a globally consolidated, independent examination and authentication system for textiles, and the implementation of voluntary regulations by various manufacturers. In addition to the currently regulated components, this method package provides analysis methods covering the major compounds in the OEKO-TEX® Standard 100 and voluntary regulations by various manufacturers.
- Certain Aromatic Amines: 24 compounds
This contains MRM information on 24 compounds, consisting of 2,4-xylidine and 2,6-xylidine in addition to 22 compounds targeted by regulations in the EU. It covers compounds targeted by regulations in a variety of countries including China and Japan.
- Azo Dyes: 51 compounds
This targets compounds that are listed in the OEKO-TEX® Standard 100 and other regulations as carcinogenic dyes and allergic dyes. Additionally, it covers 27 compounds noted in EU Directive 2009/567/EC.
- Perfluoro Compounds: 24 compounds
This targets PFOS and PFOA, which are included in the regulations, as well as their related salts, and even perfluoro compounds that are not included in the regulations at present.
- Alkylphenol Ethoxylate (APEO): 2 compounds Alkylphenol (AP): 4 compounds
This covers 2 compounds-nonylphenol ethoxylate and octylphenol ethoxylate, listed in ISO18254, and the 4 main alkylphenols.
Shared Analytical Columns
This method package contains 6 methods. A shared column is used for the 5 analyses, excluding the certain aromatic amines. Additionally, the mobile phases are shared as much as possible, with 4 aqueous solvents and 2 organic solvents. As shown in the figure below, introducing a column switching system enables the analysis of all the components targeted by this product, just by changing the combination of the mobile phase and column.
Example of a System Configuration Using Column Switching
Overview of the Methods Contained in This Method Package
Method 1 | Method 2 | Method 3 | Method 4 | Method 5 | Method 6 | |
---|---|---|---|---|---|---|
Target Compounds |
24 certain aromatic amines |
44 azo dyes | 7 azo dyes | 24 perfluoro compounds |
2 APEOs | 4 APs |
Column | Shim-pack FC-ODS (2.1 mmID x 150 mm, 3 µm) |
Shim-pack FC-ODS (2.1 mmID x 75 mm, 3 µm) |
Shim-pack FC-ODS (2.1 mmID x 75 mm, 3 µm) |
Shim-pack FC-ODS (2.1 mmID x 75 mm, 3 µm) |
Shim-pack FC-ODS (2.1 mmID x 75 mm, 3 µm) |
Shim-pack FC-ODS (2.1 mmID x 75 mm, 3 µm) |
Mobile Phase A | 5 mmol/L ammonium acetate-water |
5 mmol/L ammonium acetate-water |
5 mmol/L ammonium bicarbonate-water |
5 mmol/L ammonium acetate-water |
10 mmol/L ammonium acetate-water |
Water |
Mobile Phase B | Acetonitrile |
5 mmol/L ammonium
acetate-acetonitrile: ( 9 : 1)
|
Acetonitrile | Acetonitrile | Acetonitrile | Acetonitrile |
Run Time | 13 min | 20 min | 10 min | 13 min | 7 min | 11 min |
Precautions
LabSolutions LCMS Ver. 5.93 or later is required.
LabSolutions and Shim-pack are trademarks of Shimadzu Corporation.
The OEKO-TEX® label is an internationally registered trademark legally protected by the Madrid Agreement.
News / Events
-
Shimadzu at ASMS 2023
-
Per- and Polyfluoroalkyl Substances (PFAS)
Per-and polyfluoroalkyl substances (PFAS) are a group of persistent and harmful chemicals that can be commonly found in the environment globally. These anthropogenic chemicals can come from various sources such as manufacturing, industrial applications, food contact materials and consumer products, and eventually end up and accumulate in the water, soil and living organisms.
-
The Shimadzu LCMS-2050 High-Performance Liquid Chromatograph Mass Spectrometer and the AA-7800 series of atomic absorption spectrophotometers have received the Red Dot Design Award 2023.
The Shimadzu LCMS-2050 High-Performance Liquid Chromatograph Mass Spectrometer and the AA-7800 series of atomic absorption spectrophotometers have received the Red Dot Design Award 2023.
-
New Multi-omics Analysis Package
The Multi-omics Analysis Package is metabolic engineering software that can automatically generate metabolic maps and perform a variety of data analysis based on the vast amounts of mass spectrometry data generated in fields such as metabolomics, proteomics, and flux analysis.
-
Shimadzu has released the LC/MS/MS Method Package for Steroid Hormones.
The LC/MS/MS method package for steroid hormones contains LC/MS/MS analytical methods with optimized analytical conditions and MS parameters for analyzing 20 kinds of steroid hormones and corrective substances. The package enables comprehensive analysis of steroid hormones ranging from adrenocortical hormones, such as mineralocorticoid and glucocorticoid, to sex hormones, such as androgens, estrogens, and progestogens.
-
Life Science Biomarker Industry Page has been updated
Biomarkers are derived from living organisms and found in tissues, blood, and other bodily fluids. Biomarkers are indicators of biological changes in an organism and are used to diagnose disease, in prognosis, and to evaluate the efficacy and safety of pharmaceuticals. Biomarkers can be nucleic acids, proteins, peptides, lipids, and sugars, and are identified using various “omics” techniques.