Nexera series - Specs
Ultra High Performance Liquid Chromatograph
- Overview
- Features
- Applications
- Specs
- Downloads
- Configuration
- Columns
- Consumables
- Options
- Case Studies
- Support
Nexera X3
Pressure |
130MPa |
---|---|
Approx. particle size (*) |
sub2 μm-3μm |
I.D. (*) |
1-3mm |
Dual pump |
✔ |
Multi-rinse |
Installed as standard |
Key features |
Shimadzu’s flagship UHPLC model. This high-pressure gradient model minimizes gradient delay volume and is ideal for very high sample numbers or as the front end of an LC/MS system. It is also compatible with low-pressure gradients and mobile phase blending. |
*To achieve maximum functionality of both instruments and columns, we recommend using columns with the particle size and dimensions suggested. However, as long as the maximum pressure of the instrument and columns are not exceeded, other columns can be used.
Piping adjustments may be necessary depending on the analysis conditions. Please contact a Shimadzu sales representative for details.
Shimadzu’s flagship UHPLC model. This high-pressure gradient model minimizes gradient delay volume and is ideal for very high sample numbers or as the front end of an LC/MS system. It is also compatible with low-pressure gradients and mobile phase blending.
Model Name | Features | |
System controller | SCL-40 | Color screen with touch panel and system controller with reservoir tray Number of connectable units : 8 (Using option: 12) Connectable unit : Solvent delivery unit: max. 4, Autosampler: 1, Column oven: max. 4, Detector: max 2, etc. |
Solvent Delivery Pump | LC-40B X3 |
Pumping method : Parallel-type double plunger (approx. 10 μL/1 stroke)
Allowable maximum pressure : 130 MPa Flow rate settings range : 0.0001 – 3.0000 mL/min (1.0 – 130 MPa), 3.0001 – 5.0000 mL/min (1.0 – 80 MPa), 5.0001 – 10.0000 mL/min (1.0 – 22 MPa) Flow rate accuracy : ≦± 1% (under specified conditions) Gradient mode : High-pressure gradient (2 solvents (LC-40B X3 standard) or 3 solvents) Quaternary low-pressure gradient (Only available for LC-40D X3) |
Gradient Mixer | ||
Autosampler | SIL-40C X3 |
Injection method : Total-volume Injection (standard), loop injection (optional)
Allowable maximum pressure : 130 MPa Injection volume : 0.1 to 50 μL, 0.1 to 2000 μL (optional) Injection volume accuracy : ≦± 1% (5 μL injection, n = 20) Injection cycle time : ≦6.7 seconds (under specified conditions) |
Column Oven | CTO-40S | Temperature control type : Forced air circulation Cooling Method : Electronic cooling Temperature control range : Room temperature − 10°C to 85°C Temperature accuracy : ± 0.8°C Temperature precision : ± 0.1°C |
UV-VIS Detector | SPD-M30A |
Light source : Deuterium (D2) lamp
Number of diode elements : 1024 Wavelength range : 190 to 700 nm Wavelength accuracy : ≦± 1 nm Wavelength reproducibility : ≦± 0.1 nm |
Mobile phase monitor | ||
Software | Labsolutions LC/GC Multi LC-PDA |
Nexera XS
Pressure |
105MPa |
---|---|
Approx. particle size (*) |
sub 2μm-3μm |
I.D. (*) |
1-3mm |
Dual pump |
- |
Multi-rinse |
Optional |
Key features |
A highly flexible UHPLC model compatible with both high and low gradients. Not only does this model significantly reduce analysis time, but the use of plate-changers enables efficient analysis of a large number of samples. |
*To achieve maximum functionality of both instruments and columns, we recommend using columns with the particle size and dimensions suggested. However, as long as the maximum pressure of the instrument and columns are not exceeded, other columns can be used.
Piping adjustments may be necessary depending on the analysis conditions. Please contact a Shimadzu sales representative for details.
A highly flexible UHPLC model compatible with both high and low gradients. Not only does this model significantly reduce analysis time, but the use of plate-changers enables efficient analysis of a large number of samples.
Model Name | Features | |
System controller | SCL-40 | Color screen with touch panel and system controller with reservoir tray Number of connectable units : 8 (Using option: 12) Connectable unit : Solvent delivery unit: max. 4, Autosampler: 1, Column oven: max. 4, Detector: max 2, etc. |
Solvent Delivery Pump | LC-40D XS |
Pumping method : Parallel-type double plunger (approx. 10 μL/1 stroke)
Allowable maximum pressure : 105 MPa Flow rate settings range : 0.0001 – 3.0000 mL/min (1.0 – 105 MPa) 3.0001 – 5.0000 mL/min (1.0 – 80 MPa) 5.0001 – 10.0000 mL/min (1.0 – 22 MPa) Flow rate accuracy :≦± 1% (under specified conditions) Gradient mode : High-pressure gradient (2 or 3 solvents) Quaternary low-pressure gradient |
Gradient Mixer | ||
Degassing Unit | DGU-405 | Number of degassed solvents : 5 Degassed flow line capacity : 400 μL/1 line Operating temperature range : 4 - 35°C |
Autosampler | SIL-40C XS |
Injection method : Total-volume Injection (standard), loop injection (optional)
Allowable maximum pressure : 105 MPa Injection volume : 0.1 - 50 μL, 0.1 - 2000 μL (optional) Injection volume accuracy : ≦± 1% (5 μL injection, n = 20) Injection cycle time : ≦6.7 seconds (under specified conditions) |
Column Oven | CTO-40S | Temperature control type : Forced air circulation Cooling Method : Electronic cooling Temperature control range : Room temperature − 10°C - 85°C Temperature accuracy : ± 0.8°C Temperature precision : ± 0.1°C |
UV-VIS Detector | SPD-M30A | Light source : Deuterium (D2) lamp Number of diode elements : 1024 Wavelength range : 190 to 700 nm Wavelength accuracy : ≦± 1 nm Wavelength reproducibility : ≦± 0.1 nm |
Mobile phase monitor | ||
Software | Labsolutions LC/GC Multi LC-PDA |
Nexera XR
Pressure |
70MPa |
---|---|
Approx. particle size (*) |
2μm-3μm |
I.D. (*) |
2-4.6mm |
Dual pump |
✔ |
Multi-rinse |
Optional |
Key features |
This UHPLC-like model is the new standard for the Shimadzu LC series. It is compatible with a wide range of analysis conditions from conventional HPLC analysis to ultra-high separation analysis using core-shell columns with a particle size of 3 μm and below. |
*To achieve maximum functionality of both instruments and columns, we recommend using columns with the particle size and dimensions suggested. However, as long as the maximum pressure of the instrument and columns are not exceeded, other columns can be used.
Piping adjustments may be necessary depending on the analysis conditions. Please contact a Shimadzu sales representative for details.
This UHPLC-like model is the new standard for the Shimadzu LC series. It is compatible with a wide range of analysis conditions from conventional HPLC analysis to ultra-high separation analysis using core-shell columns with a particle size of 3 μm and below.
Model Name | Features | |
System controller | SCL-40 | Color screen with touch panel and system controller with reservoir tray Number of connectable units : 8 (Using option: 12) Connectable unit : Solvent delivery unit: max. 4, Autosampler: 1, Column oven: max. 4, Detector: max 2, etc. |
Solvent Delivery Pump | LC-40B XR |
Pumping method : Parallel-type double plunger (approx. 10 μL/1 stroke)
Allowable maximum pressure : 70 MPa Flow rate settings range : 0.0001 – 3.0000 mL/min (1.0 – 70 MPa) 3.0001 – 5.0000 mL/min (1.0 – 44 MPa) 5.0001 – 10.0000 mL/min (1.0 – 22 MPa) Flow rate accuracy : ≦± 1% or ± 2 μL/min, whichever greater (under specified conditions) Gradient mode : High-pressure gradient (2 solvents (LC-40B XR standard) or 3 solvents) Quaternary low-pressure gradient (Only available for LC-40D XR) |
Gradient Mixer | ||
Degassing Unit | DGU-403 | Number of degassed solvents : 3 Degassed flow line capacity : 400 μL/1 line Operating temperature range : 4 to 35°C |
Autosampler | SIL-40C XR |
Injection method : Total-volume Injection (standard), loop injection (optional)
Allowable maximum pressure : 80 MPa Injection volume : 0.1 to 50 μL, 0.1 to 2000 μL (optional) Injection volume accuracy : ≦± 1% (5 μL injection, n = 20) Injection cycle time : ≦6.7 seconds (under specified conditions) |
Column Oven | CTO-40S | Temperature control type : Forced air circulation Cooling Method : Electronic cooling Temperature control range : Room temperature − 10°C to 85°C Temperature accuracy : ± 0.8°C Temperature precision : ± 0.1°C |
UV-VIS Detector | SPD-M40 | Light source :Deuterium (D2) lamp, Tungsten lamp Number of diode elements : 1024 Wavelength range : 190 to 800 nm Wavelength accuracy : ≦± 1 nm Wavelength reproducibility : ≦± 0.1 nm |
Mobile phase monitor | ||
Software | Labsolutions LC/GC Multi LC-PDA |
Nexera lite
Pressure |
44MPa |
---|---|
Approx. particle size (*) |
above 3μm |
I.D. (*) |
3mm- |
Dual pump |
- |
Multi-rinse |
Optional |
Key features |
A conventional HPLC model with excellent basic functions and many options for expansion. Cutting-edge AI functions increase the reliability of established analysis workflows. It can be adapted for all application systems. |
*To achieve maximum functionality of both instruments and columns, we recommend using columns with the particle size and dimensions suggested. However, as long as the maximum pressure of the instrument and columns are not exceeded, other columns can be used.
Piping adjustments may be necessary depending on the analysis conditions. Please contact a Shimadzu sales representative for details.
A conventional HPLC model with excellent basic functions and many options for expansion. Cutting-edge AI functions increase the reliability of established analysis workflows. It can be adapted for all application systems.
Model Name | Features | |
System controller | SCL-40 | Color screen with touch panel and system controller with reservoir tray Number of connectable units : 8 (Using option: 12) Connectable unit : Solvent delivery unit: max. 4, Autosampler: 1, Column oven: max. 4, Detector: max 2, etc. |
Solvent Delivery Pump | LC-40D (2pcs) |
Pumping method : Parallel-type double plunger (approx. 10 μL/1 stroke)
Allowable maximum pressure : 44 MPa Flow rate settings range : 0.0001 – 5.0000 mL/min (1.0 – 44 MPa) 5.0001 – 10.0000 mL/min (1.0 – 22 MPa) Flow rate accuracy : ≦± 1% or ± 2 μL/min, whichever greater (under specified conditions) Gradient mode : High-pressure gradient (2 or 3 solvents) Quaternary low-pressure gradient |
Gradient Mixer | ||
Degassing Unit | DGU-403 | Number of degassed solvents : 3 Degassed flow line capacity : 400 μL/1 line Operating temperature range : 4 to 35°C |
Autosampler | SIL-40C |
Injection method : Total-volume Injection (standard), loop injection (optional)
Allowable maximum pressure : 44 MPa Injection volume : 0.1 to 100 μL, 0.1 to 2000 μL (optional) Injection volume accuracy : ≦± 1% (5 μL injection, n = 20) Injection cycle time : ≦6.7 seconds (under specied conditions) |
Column Oven | CTO-40C | Temperature control type : Forced air circulation Cooling Method : Electronic cooling Temperature control range : Room temperature − 10°C to 100°C Temperature accuracy : ± 0.5°C Temperature precision : ± 0.05°C |
UV-VIS Detector | SPD-M40 | Light source : Deuterium (D2) lamp Number of diode elements : 1024 Wavelength range : 190 to 700 nm Wavelength accuracy : ≦± 1 nm Wavelength reproducibility : ≦± 0.1 nm |
Mobile phase monitor | ||
Software | Labsolutions LC/GC Multi LC-PDA |
Model Name | Features | |
System controller | CBM-40 | Monitor : LabSolutions Web monitor Connectable unit : Solvent delivery unit: max. 4, Autosampler: 1, Column oven: max. 4, Detector: max 2, etc. Number of connectable units : 8 (Using option: 12) |
Solvent Delivery Pump | LC-40D |
Pumping method : Parallel-type double plunger (approx. 10 μL/1 stroke)
Allowable maximum pressure : 44 MPa Flow rate settings range : 0.0001 – 5.0000 mL/min (1.0 – 44 MPa) 5.0001 – 10.0000 mL/min (1.0 – 22 MPa) Flow rate accuracy : ≦± 1% or ± 2 μL/min, whichever greater(under specified conditions) Gradient mode : High-pressure gradient (2 or 3 solvents Quaternary low-pressure gradient |
Gradient Mixer | ||
Degassing Unit | DGU-405 | Number of degassed solvents : 5 Degassed flow line capacity : 400 μL/1 line Operating temperature range : 4 - 35°C |
Autosampler | SIL-40C |
Injection method : Total-volume Injection (standard), loop injection (optional)
Allowable maximum pressure : 44 MPa Injection volume : 0.1 to 100 μL, 0.1 - 2000 μL (optional) Injection volume accuracy : ≦± 1% (5 μL injection, n = 20) Injection cycle time : ≦6.7 seconds (under specified conditions) |
Column Oven | CTO-40S | Temperature control type : Forced air circulation Cooling Method : Electronic cooling Temperature control range : Room temperature ― 10°C - 85°C Temperature accuracy : ± 0.8°C Temperature precision : ± 0.1°C |
UV-VIS Detector | SPD-M40 | Light source :Deuterium (D2) lamp, Tungsten lamp Number of diode elements : 1024 Wavelength range : 190 - 800 nm Wavelength accuracy : ≦± 1 nm Wavelength reproducibility : ≦± 0.1 nm |
Mobile phase monitor | ||
Software | Labsolutions LC/GC Multi LC-PDA |