Nexera series - Consumables

Ultra High Performance Liquid Chromatograph

Solvent Delivery Unit

Plunger assembly
Parts P/N Appearance Qty Remarks
228-52069-44 228-52069-44 1 With diaphragm
Plunger Seal
Parts P/N Appearance Qty Remarks
228-52711-93 228-52711-93 1 with Backup Ring
Suction Filter
Parts P/N Appearance Qty Remarks
228-56200-48 228-56200-48 1 Assembly (stainless steel)
Line Filter
Parts P/N Appearance Qty Remarks
228-57501-92 228-57501-92 1 -
Diaphragm, rinsing seal, bearing
Parts P/N Appearance Qty Remarks
228-55272-41 228-55272-41 2 -
Check Valve
Parts P/N Appearance Qty Remarks
228-52964-42 1 -
228-48249-96 228-48249-96 1 -
228-48249-97 228-48249-97 2 -
228-45705-43 1 -
228-53334-96 228-53334-96 1 -

SIL (autosampler)

SIL Suction Filter
Parts P/N Appearance Qty Remarks
228-45707-91 228-45707-91 1 Stainless steel

Other (option)

Flow line switching valve
Parts P/N Appearance Qty Remarks
228-48858-46 228-48858-46 1 SUS316L with special coating
228-56253-44 228-56253-44 1 SUS316L with special coating
228-56253-48 1 SUS316L with special coating
228-71780-42 228-71780-42 1 PEEK
228-71780-41 228-71780-41 1 PEEK
228-71780-45 1 PEEK

Detector

LC Detector Lamp
Parts P/N Appearance Qty Remarks
228-63621-02 1 L14578-02 Guaranteed service life is 2000 hours or one year after the purchase date, whichever is shorter.
228-73407 1 L15050 Guaranteed service life is 2000 hours or one year after the purchase date.
228-73309 1 Guaranteed service life is 2000 hours or one year after the phrchase date, whichever is shorter.
228-73443 1 Guaranteed service life is 1200 hours or one year after the phrchase date, whichever is shorter.
Flow Cell
Parts P/N Appearance Qty Remarks
228-62156-42 1 Standard cell for SPD-40/40V optical path length: 10 mm, volume: 12 μL temperature control function
228-64724-42 1 UHPLC cell (ultra high-separation, high-speed analysis) optical path length: 10 mm, volume: 8μL temperature control function
228-64725-42 1 Semi micro cell optical path length: 5 mm, volume: 2.5 μL temperature control function
228-68250-42 1 Cell for conventional analysis optical path length: 10 mm, volume: 12 μL It has the same internal capacity as the SPD-20A/20AV standard cell.
228-64728-42 1 Inert cell optical path length: 10 mm, volume: 12 μL temperature control function
228-64727-42 1 Preparative cell, optical path length: 0.5 mm(variable among 0.1, 0.2, 0.5 mm), volume: 4 μL
228-64737-42 1 Micro cell optical path length: 3 mm, volume: 0.21 μL
228-64726-42 1 Cell for high pressure resistance (pressure resistance : 40MPa) optical path length: 10 mm, volume: 12 μL
228-62156-41 1 Standard cell for SPD-M40 optical path length: 10 mm, volume: 12 μL, with temperature control function
228-64724-41 1 UHPLC cell (ultra high-separation, high-speed analysis) optical path length: 10 mm, volume: 8μL, with temperature control function
228-64725-41 1 Semi micro cell optical path length: 5 mm, volume: 2.5 μL, with temperature control function
228-68250-41 1 Cell for conventional analysis optical path length: 10 mm, volume: 12 μL It has the same internal capacity as the SPD-20A/20AV standard cell.
228-64728-41 1 Inert cell optical path length: 10 mm, volume: 12 μL, with temperature control function
228-64727-41 1 Preparative cell optical path length: 0.5 mm (variable among 0.1, 0.2 0.5 mm), volume: 4 μL
228-64737-41 1 Micro LC cell optical path length: 3 mm, volume: 0.21 μL
228-64726-41 1 High pressure resistance (pressure resistance: 40 MPa) optical path length: 10 mm, volume: 12 μL