Shimadzu LC Driver for Waters Empower

Products

Descriptions Notes
Shimadzu LC Driver for Waters Empower Software Support Services (for 1 system) For Empower Personal and Enterprise versions.
Shimadzu LC Driver for Waters Empower Software Support Services (for 4 systems) For Empower Personal and Enterprise versions.

Supported devices

Unit Model Name Minimum required
ROM Version
System Controller CBM-20A, CBM-20Alite 3.50
Pump LC-30AD 3.21
LC-20AD 2.11
LC-20ADXR 1.23
LC-20AT 2.01
LC-20AB 2.02
LC-20Ai 1.00
Column Oven CTO-30A 3.11
CTO-20A, CTO-20AC 2.10
CTO-10AS VP 5.28
Autosampler SIL-30AC 3.20
SIL-30ACFV 3.20

SIL-20A, SIL-20AC

(including HT and UFLC models)

1.28
SIL-20AXR, SIL-20ACXR 1.28
Rack Changer II 2.00
Rack Changer, Rack Changer C 1.11
Sub Controller Sub Controller VP 5.22
Option Box VP
Detector SPD-20A, SPD-20AV 2.03
RF-20A, RF-20AXS 2.02
RF-10AXL 3.33
RID-20A 1.02
CDD-10Asp, CDD-10Avp 5.10
SPD-M20A 2.03
SPD-M30A 4.02
SPD-30AM 4.01
AD Input Board (PC-55N) -
Mobile Phase Flow Line Switching Valve

FCV-10AL / FCV-10ALvp / FCV-11AL / FCV-11ALS

/ FCV-15AL /Switching Valve
4-port solenoid valve built into

LC-20AD / LC-20AT / LC30-AD

-
High-Pressure Flow-Line Switching Valve FCV-12AH / FCV-13AL / FCV-14AH -
 

FCV-12AH / FCV-14H / FCV-32AH built into

CTO-20A / CTO-20AC / CTO-30A

-
  • * 4 systems maximum with no PDA or 3 systems with single PDA or 2 systems with 2 PDA (per LAC/E).
  • * CBM-20A lite will not support analogue data acquisition. Please use CBM-20A with a PC-55N AD board if analogue signal is acquired.
  •  

Configuration examples

Empower Personal (Stand-alone type)

Empower Personal is a stand-alone type configuration. A PC includes a database and data acquisition functions. A single PC is connected directly to LC system(s), and a maximum of 4 LC systems can be controlled.

Empower Enterprise (Network type)

Empower Enterprise is a client-server (C/S) system, which allows any client PC on the network to control any HPLC. HPLC control and data acquisition are done through an acquisition server called LAC/E32, and the acquired data are stored in the database server. Analysis instructions and LC instrument status monitoring are performed from a client PC. Each Shimadzu LC system is controlled by TCP/IP protocol from a PC. If any problem occurs in a LC system on the network, other LC systems in operation are not affected.

Waters® and Empower® are registered trademarks of Waters in the USA and other countries

For Research Use Only. Not for use in diagnostic procedures.